Functional shoulder radiography with use of a dynamic flat panel detector

被引:3
|
作者
Sakuda K. [1 ,2 ]
Sanada S. [3 ]
Tanaka R. [3 ]
Kitaoka K. [4 ]
Hayashi N. [5 ]
Matsuura Y. [2 ]
机构
[1] Division of Health Sciences, Graduate School of Medical Science, Kanazawa University, Kanazawa, Ishikawa 920-0942
[2] Department of Radiological Technology, Kanazawa University Hospital, Kanazawa, Ishikawa 920-8641
[3] Department of Radiological Technology, School of Health Sciences, Kanazawa University, Kanazawa, Ishikawa 920-0942
[4] Department of Orthopedic Surgery, Koujinkai Kijima Hospital, Kanazawa, Ishikawa 920-0011
[5] School of Radiological Technology, Gunma Prefectural College of Health Science, Maebashi, Gunma 371-0052
基金
日本学术振兴会;
关键词
Dynamic flat panel detector; Ratio of G-angle to S-angle (GSR); Scapulohumeral rhythm; Scapulothoracic angle; Shoulder joint;
D O I
10.1007/s12194-014-0257-2
中图分类号
学科分类号
摘要
Our purpose in this study was to develop a functional form of radiography and to perform a quantitative analysis for the shoulder joint using a dynamic flat panel detector (FPD) system. We obtained dynamic images at a rate of 3.75 frames per second (fps) using an FPD system. Three patients and 5 healthy controls were studied with a clinically established frontal projection, with abduction of the arms. The arm angle, glenohumeral angle (G-angle), and scapulothoracic angle (S-angle) were measured on dynamic images. The ratio of the G-angle to the S-angle (GSR) was also evaluated quantitatively. In normal subjects, the G-angle and S-angle changed gradually along with the arm angle. The G-angle was approximately twice as large as the S-angle, resulting in a GSR of 2 throughout the abduction of the shoulder. Changes in G-angle and S-angle tended to be irregular in patients with shoulder disorders. The GSR of the thoracic outlet syndrome, recurrent dislocation of the shoulder joint, and anterior serratus muscle paralysis were 3-7.5, 4-9.5, and 3.5-7.5, respectively. The GSR of the anterior serratus muscle paralysis improved to approximately 2 after orthopedic treatment. Our preliminary results indicated that functional radiography by FPD and computer-aided quantitative analysis is useful for diagnosis of some shoulder disorders, such as the thoracic outlet syndrome, recurrent dislocation of the shoulder joint, and anterior serratus muscle paralysis. The technique and procedures described comprise a simple, functional shoulder radiographic method for evaluation of the therapeutic effects of surgery and/or rehabilitation. © 2014 The Author(s).
引用
收藏
页码:254 / 261
页数:7
相关论文
共 50 条
  • [1] Flat Panel Detector Radiography Calibration and Enhancement
    Cao, Zhi-Yang
    Huang, Qian
    Huang, Zi-Chun
    Yan, Ke
    [J]. 2015 International Conference on Software Engineering and Information System (SEIS 2015), 2015, : 386 - 391
  • [2] Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging
    Tanaka R.
    [J]. Radiological Physics and Technology, 2016, 9 (2) : 139 - 153
  • [3] Detectability of regional lung ventilation with flat-panel detector-based dynamic radiography
    Tanaka, Rie
    Sanada, Shigeru
    Okazaki, Nobuo
    Kobayashi, Takeshi
    Suzuki, Masayuki
    Matsui, Takeshi
    Matsui, Osamu
    [J]. JOURNAL OF DIGITAL IMAGING, 2008, 21 (01) : 109 - 120
  • [4] Detectability of Regional Lung Ventilation with Flat-panel Detector-based Dynamic Radiography
    Rie Tanaka
    Shigeru Sanada
    Nobuo Okazaki
    Takeshi Kobayashi
    Masayuki Suzuki
    Takeshi Matsui
    Osamu Matsui
    [J]. Journal of Digital Imaging, 2008, 21
  • [5] Dynamic chest radiography with a flat-panel detector (FPD): Ventilation-perfusion study
    Tanaka, R.
    Sanada, S.
    Fujimura, M.
    Yasui, M.
    Tsuji, S.
    Hayashi, N.
    Okamoto, H.
    Nanbu, Y.
    Matsui, O.
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [6] Breathing chest radiography using a dynamic flat-panel detector combined with computer analysis
    Tanaka, R
    Sanada, S
    Suzuki, M
    Kobayashi, T
    Matsui, T
    Inoue, H
    Yoshihisa, N
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2254 - 2262
  • [7] Development of functional chest imaging with a dynamic flat-panel detector (FPD).
    Tanaka R.
    Sanada S.
    Fujimura M.
    Yasui M.
    Nakayama K.
    Matsui T.
    Hayashi N.
    Matsui O.
    [J]. Radiological Physics and Technology, 2008, 1 (2) : 137 - 143
  • [8] A flat-panel detector digital radiography and a storage phosphor computed radiography: Screening for pneumoconioses
    Takashima, Yoshihiro
    Suganuma, Narufumi
    Sakurazawa, Hirofumi
    Itoh, Harumi
    Hirano, Harukazu
    Shida, Hisao
    Kusaka, Yukinori
    [J]. JOURNAL OF OCCUPATIONAL HEALTH, 2007, 49 (01) : 39 - 45
  • [9] Quantitative kinetic analysis of lung nodules by temporal subtraction technique in dynamic chest radiography with a flat panel detector
    Tsuchiya, Yuichiro
    Kodera, Yoshie
    Tanaka, Rie
    Sanada, Shigeru
    [J]. MEDICAL IMAGING 2007: COMPUTER-AIDED DIAGNOSIS, PTS 1 AND 2, 2007, 6514
  • [10] Quantitative analysis of respiratory kinetics in chest screening radiography by dynamic flat-panel detector (FPD) system
    Tanaka, R
    Sanada, S
    Suzuki, M
    Kobayashi, T
    Matsui, T
    Inoue, H
    [J]. RADIOLOGY, 2002, 225 : 187 - 188