Development of functional chest imaging with a dynamic flat-panel detector (FPD).

被引:8
|
作者
Tanaka R. [1 ]
Sanada S. [1 ]
Fujimura M. [1 ]
Yasui M. [1 ]
Nakayama K. [1 ]
Matsui T. [1 ]
Hayashi N. [1 ]
Matsui O. [1 ]
机构
[1] Department of Radiological Technology, Graduate School of Medical Science, Kanazawa University, Kodatsuno, Kanazawa
关键词
Functional imaging; Dynamic chest radiography; Flat-panel detector; Blood flow; Visualization; Image subtraction;
D O I
10.1007/s12194-008-0020-7
中图分类号
学科分类号
摘要
Dynamic FPD permits the acquisition of distortion-free radiographs with a large field of view and high image quality. In the present study, we investigated the feasibility of functional imaging for evaluating the pulmonary sequential blood distribution with an FPD, based on changes in pixel values during cardiac pumping. Dynamic chest radiographs of seven normal subjects were obtained in the expiratory phase by use of an FPD system. We measured the average pixel value in each region of interest that was located manually in the heart and lung areas. Subsequently, inter-frame differences and differences from a minimum-intensity projection image, which was created from one cardiac cycle, were calculated. These difference values were then superimposed on dynamic chest radiographs in the form of a color display, and sequential blood distribution images and a blood distribution map were created. The results were compared to typical data on normal cardiac physiology. The clinical effectiveness of our method was evaluated in a patient who had abnormal pulmonary blood flow. In normal cases, there was a strong correlation between the cardiac cycle and changes in pixel value. Sequential blood distribution images showed a normal pattern at determined by the physiology of pulmonary blood flow, with a symmetric distribution and no blood flow defects throughout the entire lung region. These findings indicated that pulmonary blood flow was reflected on dynamic chest radiographs. In an abnormal case, a defect in blood flow was shown as defective in color in a blood distribution map. The present method has the potential for evaluation of local blood flow as an optional application in general chest radiography.
引用
收藏
页码:137 / 143
页数:6
相关论文
共 50 条
  • [1] Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging
    Tanaka R.
    [J]. Radiological Physics and Technology, 2016, 9 (2) : 139 - 153
  • [2] Dynamic chest radiography with a flat-panel detector (FPD): Ventilation-perfusion study
    Tanaka, R.
    Sanada, S.
    Fujimura, M.
    Yasui, M.
    Tsuji, S.
    Hayashi, N.
    Okamoto, H.
    Nanbu, Y.
    Matsui, O.
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [3] Quantitative analysis of respiratory kinetics in chest screening radiography by dynamic flat-panel detector (FPD) system
    Tanaka, R
    Sanada, S
    Suzuki, M
    Kobayashi, T
    Matsui, T
    Inoue, H
    [J]. RADIOLOGY, 2002, 225 : 187 - 188
  • [4] Computerized Methods for Determining Respiratory Phase on Dynamic Chest Radiographs Obtained by a Dynamic Flat-Panel Detector (FPD) System
    Rie Tanaka
    Shigeru Sanada
    Takeshi Kobayashi
    Masayuki Suzuki
    Takeshi Matsui
    Osamu Matsui
    [J]. Journal of Digital Imaging, 2006, 19 : 41 - 51
  • [5] Computerized methods for determining respiratory phase on dynamic chest radiographs obtained by a dynamic flat-panel detector (FPD) system
    Tanaka, R
    Sanada, S
    Kobayashi, T
    Suzuki, M
    Matsui, T
    Inoue, H
    Nanbu, Y
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1735 - 1735
  • [6] Computerized methods for determining respiratory phase on dynamic chest radiographs obtained by a dynamic flat-panel detector (FPD) system
    Tanaka, R
    Sanada, S
    Kobayashi, T
    Suzuki, M
    Matsui, T
    Matsui, O
    [J]. JOURNAL OF DIGITAL IMAGING, 2006, 19 (01) : 41 - 51
  • [7] Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography
    Floyd, CE
    Warp, RJ
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Vargas-Voracek, R
    Ravin, CE
    [J]. RADIOLOGY, 2001, 218 (03) : 683 - 688
  • [8] Breathing chest radiography using a dynamic flat-panel detector combined with computer analysis
    Tanaka, R
    Sanada, S
    Suzuki, M
    Kobayashi, T
    Matsui, T
    Inoue, H
    Yoshihisa, N
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2254 - 2262
  • [9] Portal imaging with flat-panel detector and CCD camera
    Roehrig, H
    Tang, CK
    Cheng, CW
    Dallas, WJ
    [J]. HARD X-RAY AND GAMMA-RAY DETECTOR PHYSICS, OPTICS, AND APPLICATIONS, 1997, 3115 : 323 - 333
  • [10] Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications
    Hata, Akinori
    Yamada, Yoshitake
    Tanaka, Rie
    Nishino, Mizuki
    Hida, Tomoyuki
    Hino, Takuya
    Ueyama, Masako
    Yanagawa, Masahiro
    Kamitani, Takeshi
    Kurosaki, Atsuko
    Sanada, Shigeru
    Jinzaki, Masahiro
    Ishigami, Kousei
    Tomiyama, Noriyuki
    Honda, Hiroshi
    Kudoh, Shoji
    Hatabu, Hiroto
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (04) : 634 - 651