Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications

被引:18
|
作者
Hata, Akinori [1 ]
Yamada, Yoshitake [2 ]
Tanaka, Rie [3 ]
Nishino, Mizuki [1 ]
Hida, Tomoyuki [4 ]
Hino, Takuya [1 ]
Ueyama, Masako [5 ]
Yanagawa, Masahiro [7 ]
Kamitani, Takeshi [4 ]
Kurosaki, Atsuko [6 ]
Sanada, Shigeru [8 ]
Jinzaki, Masahiro [2 ]
Ishigami, Kousei [4 ]
Tomiyama, Noriyuki [7 ]
Honda, Hiroshi [4 ]
Kudoh, Shoji [9 ]
Hatabu, Hiroto [1 ]
机构
[1] Harvard Med Sch, Brigham & Womens Hosp, Dept Radiol, Ctr Pulm Funct Imaging, 75 Francis St, Boston, MA 02115 USA
[2] Keio Univ, Dept Diagnost Radiol, Sch Med, Tokyo, Japan
[3] Kanazawa Univ, Sch Hlth Sci, Dept Radiol Technol, Coll Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
[4] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Fukuoka, Japan
[5] Japan AntiTB Assoc, Fukujuji Hosp, Dept Hlth Care, Tokyo, Japan
[6] Japan AntiTB Assoc, Fukujuji Hosp, Dept Diagnost Radiol, Tokyo, Japan
[7] Osaka Univ, Grad Sch Med, Dept Diagnost & Intervent Radiol, Osaka, Japan
[8] Komatsu Univ, Clin Engn, Komatsu, Ishikawa, Japan
[9] Japan AntiTB Assoc, Tokyo, Japan
关键词
Dynamic X-ray; Flat-panel detector; Functional imaging; Diaphragmatic motion; Ventilation; Perfusion; OBSTRUCTIVE PULMONARY-DISEASE; RESOLVED QUANTITATIVE-EVALUATION; DIAPHRAGMATIC MOTION; IMAGE INTENSIFIER; STANDING POSITION; LUNG VENTILATION; RADIATION-THERAPY; COPD PATIENTS; BLOOD-VOLUME; RADIOGRAPHY;
D O I
10.3348/kjr.2020.1136
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dynamic X-ray (DXR) is a functional imaging technique that uses sequential images obtained by a flat-panel detector (FPD). This article aims to describe the mechanism of DXR and the analysis methods used as well as review the clinical evidence for its use. DXR analyzes dynamic changes on the basis of X-ray translucency and can be used for analysis of diaphragmatic kinetics, ventilation, and lung perfusion. It offers many advantages such as a high temporal resolution and flexibility in body positioning. Many clinical studies have reported the feasibility of DXR and its characteristic findings in pulmonary diseases. DXR may serve as an alternative to pulmonary function tests in patients requiring contact inhibition, including patients with suspected or confirmed coronavirus disease 2019 or other infectious diseases. Thus, DXR has a great potential to play an important role in the clinical setting. Further investigations are needed to utilize DXR more effectively and to establish it as a valuable diagnostic tool.
引用
收藏
页码:634 / 651
页数:18
相关论文
共 50 条
  • [1] Dynamic chest radiography: flat-panel detector (FPD) based functional X-ray imaging
    Tanaka R.
    [J]. Radiological Physics and Technology, 2016, 9 (2) : 139 - 153
  • [2] A LabVIEW driver for X-ray flat-panel detector
    Bi, Kun
    Liu, Qian
    Lv, Xiaohua
    Luo, Qingming
    Zeng, Shaoqun
    [J]. JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2008, 16 (04) : 261 - 268
  • [3] Measurement of the properties of a flat-panel gas X-ray detector
    Yun, Min-seok
    Cho, Sung-ho
    Oh, Kyung-min
    Kim, Min-woo
    Jung, Suk-hee
    Jang, Gi-won
    Heo, Seung-uk
    Kwon, Chul
    Nam, Sang-Hee
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 162 - 165
  • [4] X-ray scatter data for flat-panel detector CT
    Kyriakou, Yiannis
    Kalender, Willi A.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2007, 23 (01): : 3 - 15
  • [5] Physical Characteristics of a New Flat-Panel Digital X-Ray Detector
    Cho, H.
    Kim, H.
    Park, H.
    Lee, C.
    Yu, A.
    Kim, D.
    Lee, Y.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [6] High resolution flat-panel X-ray detector for digital radiography
    Park, JK
    Kang, SS
    Cha, BY
    Kim, JY
    Kim, SY
    Choi, HK
    Nam, SH
    [J]. Healthcom 2005: 7th International Workshop on Enterprise Networking and Computing in Healthcare Industry, Proceedings, 2005, : 359 - 363
  • [7] Optimum radiographic technique for chest radiography using a flat-panel digital detector
    Samei, E
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Floyd, CE
    Ravin, CE
    [J]. RADIOLOGY, 2002, 225 : 642 - 643
  • [8] Prospects for x-ray exposure reduction using digital radiography with a flat-panel detector
    Okusako, K
    Hatagawa, M
    Kishimoto, K
    Tanaka, K
    Kudo, H
    Yamada, R
    [J]. RADIOLOGY, 2001, 221 : 158 - 158
  • [9] Chest radiography: Optimization of X-ray spectrum for cesium iodide-amorphous silicon flat-panel detector
    Dobbins, JT
    Samei, E
    Chotas, HG
    Warp, RJ
    Baydush, AH
    Floyd, CE
    Ravin, CE
    [J]. RADIOLOGY, 2003, 226 (01) : 221 - 230
  • [10] Automated analysis for the respiratory kinetics with the screening dynamic chest radiography using a flat-panel detector system
    Tanaka, R
    Sanada, S
    Kobayashi, T
    Suzuki, M
    Matsui, T
    Inoue, H
    [J]. CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 179 - 186