Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications

被引:18
|
作者
Hata, Akinori [1 ]
Yamada, Yoshitake [2 ]
Tanaka, Rie [3 ]
Nishino, Mizuki [1 ]
Hida, Tomoyuki [4 ]
Hino, Takuya [1 ]
Ueyama, Masako [5 ]
Yanagawa, Masahiro [7 ]
Kamitani, Takeshi [4 ]
Kurosaki, Atsuko [6 ]
Sanada, Shigeru [8 ]
Jinzaki, Masahiro [2 ]
Ishigami, Kousei [4 ]
Tomiyama, Noriyuki [7 ]
Honda, Hiroshi [4 ]
Kudoh, Shoji [9 ]
Hatabu, Hiroto [1 ]
机构
[1] Harvard Med Sch, Brigham & Womens Hosp, Dept Radiol, Ctr Pulm Funct Imaging, 75 Francis St, Boston, MA 02115 USA
[2] Keio Univ, Dept Diagnost Radiol, Sch Med, Tokyo, Japan
[3] Kanazawa Univ, Sch Hlth Sci, Dept Radiol Technol, Coll Med Pharmaceut & Hlth Sci, Kanazawa, Ishikawa, Japan
[4] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Fukuoka, Japan
[5] Japan AntiTB Assoc, Fukujuji Hosp, Dept Hlth Care, Tokyo, Japan
[6] Japan AntiTB Assoc, Fukujuji Hosp, Dept Diagnost Radiol, Tokyo, Japan
[7] Osaka Univ, Grad Sch Med, Dept Diagnost & Intervent Radiol, Osaka, Japan
[8] Komatsu Univ, Clin Engn, Komatsu, Ishikawa, Japan
[9] Japan AntiTB Assoc, Tokyo, Japan
关键词
Dynamic X-ray; Flat-panel detector; Functional imaging; Diaphragmatic motion; Ventilation; Perfusion; OBSTRUCTIVE PULMONARY-DISEASE; RESOLVED QUANTITATIVE-EVALUATION; DIAPHRAGMATIC MOTION; IMAGE INTENSIFIER; STANDING POSITION; LUNG VENTILATION; RADIATION-THERAPY; COPD PATIENTS; BLOOD-VOLUME; RADIOGRAPHY;
D O I
10.3348/kjr.2020.1136
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dynamic X-ray (DXR) is a functional imaging technique that uses sequential images obtained by a flat-panel detector (FPD). This article aims to describe the mechanism of DXR and the analysis methods used as well as review the clinical evidence for its use. DXR analyzes dynamic changes on the basis of X-ray translucency and can be used for analysis of diaphragmatic kinetics, ventilation, and lung perfusion. It offers many advantages such as a high temporal resolution and flexibility in body positioning. Many clinical studies have reported the feasibility of DXR and its characteristic findings in pulmonary diseases. DXR may serve as an alternative to pulmonary function tests in patients requiring contact inhibition, including patients with suspected or confirmed coronavirus disease 2019 or other infectious diseases. Thus, DXR has a great potential to play an important role in the clinical setting. Further investigations are needed to utilize DXR more effectively and to establish it as a valuable diagnostic tool.
引用
收藏
页码:634 / 651
页数:18
相关论文
共 50 条
  • [21] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Kim, JY
    Park, JK
    Choi, JY
    Cha, BY
    Kang, SS
    An, SH
    Nam, SH
    Choi, HK
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 4048 - 4052
  • [22] Experimental evaluation of a-Se flat-panel X-ray detector for digital radiography
    Choi, JY
    Park, JK
    Lee, DG
    Kang, SS
    Nam, SH
    [J]. NEW APPLICATIONS FOR WIDE-BANDGAP SEMICONDUCTORS, 2003, 764 : 265 - 270
  • [23] Addressable flat-panel x-ray sources for medical, security and industrial applications
    Travish, Gil
    Rangel, Felix. J.
    Evans, Mark Andrew
    Hollister, Ben
    Schmiedehausen, Kristin
    [J]. ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS VII, 2012, 8502
  • [24] Unfolding X-ray spectra using a flat panel detector
    Gallardo, Sergio
    Juste, Belen
    Pozuelo, Fausto
    Rodenas, Jose
    Querol, Andrea
    Verdu, Gumersindo
    [J]. 2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 2384 - 2387
  • [25] Optimization of X-ray image acquisition and reconstruction for a C-arm CBCT system with a flat-panel detector
    Cha, Bo Kyung
    Jeon, Seongchae
    Seo, Chang-Woo
    Back, Jongduck
    Choi, Shinkook
    Lee, Changwoo
    Ahn, Miseob
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 924 : 343 - 349
  • [26] Digital radiography system with a full-size, flat-panel X-ray detector: Evaluation of imaging performance
    Neitzel, U
    Maack, I
    Rindt, K
    Spiess, K
    [J]. RADIOLOGY, 1998, 209P : 161 - 161
  • [27] Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
    Hennigs, SP
    Garmer, M
    Jaeger, HJ
    Classen, R
    Jacobs, A
    Gissler, HM
    Christmann, A
    Mathias, K
    [J]. EUROPEAN RADIOLOGY, 2001, 11 (09) : 1688 - 1696
  • [28] Digital radiography with a large-area, amorphous-silicon, flat-panel X-ray detector system
    Spahn, M
    Strotzer, M
    Völk, M
    Böhm, S
    Geiger, B
    Hahm, G
    Feuerbach, S
    [J]. INVESTIGATIVE RADIOLOGY, 2000, 35 (04) : 260 - 266
  • [29] Digital chest radiography with a large-area flat-panel silicon X-ray detector: clinical comparison with conventional radiography
    Svenja P. Hennigs
    Marietta Garmer
    Horst J. Jaeger
    Reinhard Classen
    Andreas Jacobs
    Hans M. Gissler
    Andreas Christmann
    Klaus Mathias
    [J]. European Radiology, 2001, 11 : 1688 - 1696
  • [30] Evaluation of image lag in a flat-panel, detector-equipped cardiovascular X-ray machine using a newly developed dynamic phantom
    Sato, Hisaya
    Kondo, Keisuke
    Kato, Kyoichi
    Nakazawa, Yasuo
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (02): : 366 - 375