Automated analysis for the respiratory kinetics with the screening dynamic chest radiography using a flat-panel detector system

被引:2
|
作者
Tanaka, R [1 ]
Sanada, S [1 ]
Kobayashi, T [1 ]
Suzuki, M [1 ]
Matsui, T [1 ]
Inoue, H [1 ]
机构
[1] Kanazawa Univ, Fac Med, Sch Hlth Sci, Dept Radiol Technol, Kanazawa, Ishikawa 9200942, Japan
关键词
respiratory kinetics; automated analysis; dynamic chest radiography;
D O I
10.1016/S0531-5131(03)00359-5
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
We have developed a new method for analyzing respiratory kinetics, such as the movement of the diaphragm, the movement of the chest wall, and the respiratory change in X-ray translucency in local lung fields on dynamic chest radiographs. Our approach could provide some respiratory kinetic information as well as severity of disease on image findings. In addition, the results of the movement analysis of the diaphragm well correlated with respiratory functional tests. It was concluded that dynamic chest radiography and our analysis method may be an effective aid for the evaluation of chronic obstructive pulmonary disease, pulmonary fibrosis, pneumonia, and other pulmonary diseases. (C) 2003 Published by Elsevier Science B.V.
引用
收藏
页码:179 / 186
页数:8
相关论文
共 50 条
  • [1] Quantitative analysis of respiratory kinetics in chest screening radiography by dynamic flat-panel detector (FPD) system
    Tanaka, R
    Sanada, S
    Suzuki, M
    Kobayashi, T
    Matsui, T
    Inoue, H
    [J]. RADIOLOGY, 2002, 225 : 187 - 188
  • [2] Breathing chest radiography using a dynamic flat-panel detector combined with computer analysis
    Tanaka, R
    Sanada, S
    Suzuki, M
    Kobayashi, T
    Matsui, T
    Inoue, H
    Yoshihisa, N
    [J]. MEDICAL PHYSICS, 2004, 31 (08) : 2254 - 2262
  • [3] Optimum radiographic technique for chest radiography using a flat-panel digital detector
    Samei, E
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Floyd, CE
    Ravin, CE
    [J]. RADIOLOGY, 2002, 225 : 642 - 643
  • [4] Dynamic chest radiography with a flat-panel detector (FPD): Ventilation-perfusion study
    Tanaka, R.
    Sanada, S.
    Fujimura, M.
    Yasui, M.
    Tsuji, S.
    Hayashi, N.
    Okamoto, H.
    Nanbu, Y.
    Matsui, O.
    [J]. MEDICAL IMAGING 2011: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2011, 7965
  • [5] Radiation dose reduction in chest radiography using a flat-panel amorphous silicon detector
    Hosch, WP
    Fink, C
    Radeleff, B
    Kampschulte, A
    Kauffmann, GW
    Hansmann, J
    [J]. CLINICAL RADIOLOGY, 2002, 57 (10) : 902 - 907
  • [6] Chest radiography with a digital flat-panel detector: Experimental receiver operating characteristic analysis
    Metz, S
    Damoser, P
    Hollweck, R
    Roggel, R
    Engelke, C
    Woertler, K
    Renger, B
    Rummeny, EJ
    Link, TM
    [J]. RADIOLOGY, 2005, 234 (03) : 776 - 784
  • [7] Dynamic Chest X-Ray Using a Flat-Panel Detector System: Technique and Applications
    Hata, Akinori
    Yamada, Yoshitake
    Tanaka, Rie
    Nishino, Mizuki
    Hida, Tomoyuki
    Hino, Takuya
    Ueyama, Masako
    Yanagawa, Masahiro
    Kamitani, Takeshi
    Kurosaki, Atsuko
    Sanada, Shigeru
    Jinzaki, Masahiro
    Ishigami, Kousei
    Tomiyama, Noriyuki
    Honda, Hiroshi
    Kudoh, Shoji
    Hatabu, Hiroto
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2021, 22 (04) : 634 - 651
  • [8] Computerized Methods for Determining Respiratory Phase on Dynamic Chest Radiographs Obtained by a Dynamic Flat-Panel Detector (FPD) System
    Rie Tanaka
    Shigeru Sanada
    Takeshi Kobayashi
    Masayuki Suzuki
    Takeshi Matsui
    Osamu Matsui
    [J]. Journal of Digital Imaging, 2006, 19 : 41 - 51
  • [9] Computerized methods for determining respiratory phase on dynamic chest radiographs obtained by a dynamic flat-panel detector (FPD) system
    Tanaka, R
    Sanada, S
    Kobayashi, T
    Suzuki, M
    Matsui, T
    Matsui, O
    [J]. JOURNAL OF DIGITAL IMAGING, 2006, 19 (01) : 41 - 51
  • [10] Computerized methods for determining respiratory phase on dynamic chest radiographs obtained by a dynamic flat-panel detector (FPD) system
    Tanaka, R
    Sanada, S
    Kobayashi, T
    Suzuki, M
    Matsui, T
    Inoue, H
    Nanbu, Y