Development of functional chest imaging with a dynamic flat-panel detector (FPD).

被引:8
|
作者
Tanaka R. [1 ]
Sanada S. [1 ]
Fujimura M. [1 ]
Yasui M. [1 ]
Nakayama K. [1 ]
Matsui T. [1 ]
Hayashi N. [1 ]
Matsui O. [1 ]
机构
[1] Department of Radiological Technology, Graduate School of Medical Science, Kanazawa University, Kodatsuno, Kanazawa
关键词
Functional imaging; Dynamic chest radiography; Flat-panel detector; Blood flow; Visualization; Image subtraction;
D O I
10.1007/s12194-008-0020-7
中图分类号
学科分类号
摘要
Dynamic FPD permits the acquisition of distortion-free radiographs with a large field of view and high image quality. In the present study, we investigated the feasibility of functional imaging for evaluating the pulmonary sequential blood distribution with an FPD, based on changes in pixel values during cardiac pumping. Dynamic chest radiographs of seven normal subjects were obtained in the expiratory phase by use of an FPD system. We measured the average pixel value in each region of interest that was located manually in the heart and lung areas. Subsequently, inter-frame differences and differences from a minimum-intensity projection image, which was created from one cardiac cycle, were calculated. These difference values were then superimposed on dynamic chest radiographs in the form of a color display, and sequential blood distribution images and a blood distribution map were created. The results were compared to typical data on normal cardiac physiology. The clinical effectiveness of our method was evaluated in a patient who had abnormal pulmonary blood flow. In normal cases, there was a strong correlation between the cardiac cycle and changes in pixel value. Sequential blood distribution images showed a normal pattern at determined by the physiology of pulmonary blood flow, with a symmetric distribution and no blood flow defects throughout the entire lung region. These findings indicated that pulmonary blood flow was reflected on dynamic chest radiographs. In an abnormal case, a defect in blood flow was shown as defective in color in a blood distribution map. The present method has the potential for evaluation of local blood flow as an optional application in general chest radiography.
引用
下载
收藏
页码:137 / 143
页数:6
相关论文
共 50 条
  • [11] Characteristics of a Neutron Imaging Flat Panel Detector (FPD) for Proton Therapy
    Cheng, C.
    Lee, S.
    Yuan, J.
    Lu, M.
    MEDICAL PHYSICS, 2017, 44 (06) : 3021 - 3021
  • [12] Development of a cardiac evaluation method using a dynamic flat-panel detector (FPD) system: a feasibility study using a cardiac motion phantom.
    Tanaka R.
    Sanada S.
    Tsujioka K.
    Matsui T.
    Takata T.
    Matsui O.
    Radiological Physics and Technology, 2008, 1 (1) : 27 - 32
  • [13] Imaging performance of a direct digital flat-panel radiographic detector
    Kengyelics, SM
    Davies, AG
    Launders, JH
    Cowen, AR
    Richardson, DL
    Wilson, P
    RADIOLOGY, 1998, 209P : 358 - 358
  • [14] Automated analysis for the respiratory kinetics with the screening dynamic chest radiography using a flat-panel detector system
    Tanaka, R
    Sanada, S
    Kobayashi, T
    Suzuki, M
    Matsui, T
    Inoue, H
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 179 - 186
  • [15] Investigation on Effect of Image Lag in Fluoroscopic Images Obtained with a Dynamic Flat-panel Detector (FPD) on Accuracy of Target Tracking in Radiotherapy
    Tanaka, Rie
    Ichikawa, Katsuhiro
    Mori, Shinichiro
    Dobashi, Suguru
    Kumagai, Motoki
    Kawashima, Hiroki
    Minohara, Shinichi
    Sanada, Sigeru
    JOURNAL OF RADIATION RESEARCH, 2010, 51 (06) : 723 - 731
  • [16] Optimum radiographic technique for chest radiography using a flat-panel digital detector
    Samei, E
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Floyd, CE
    Ravin, CE
    RADIOLOGY, 2002, 225 : 642 - 643
  • [17] Chest imaging with flat-panel detector at low and standard doses:: comparison with storage phosphor technology in normal patients
    Herrmann, KA
    Bonél, H
    Stäbler, A
    Kulinna, C
    Glaser, C
    Holzknecht, N
    Geiger, B
    Schätzl, M
    Reiser, MF
    EUROPEAN RADIOLOGY, 2002, 12 (02) : 385 - 390
  • [18] Imaging performance of amorphous selenium flat-panel detector for digital fluoroscopy
    Hunt, DC
    Tousignanth, O
    Demers, Y
    Laperrière, L
    Rowlands, JA
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 226 - 234
  • [19] Chest imaging with flat-panel detector at low and standard doses: comparison with storage phosphor technology in normal patients
    K. Herrmann
    H. Bonél
    A. Stäbler
    C. Kulinna
    C. Glaser
    N. Holzknecht
    B. Geiger
    M. Schätzl
    M. Reiser
    European Radiology, 2002, 12 : 385 - 390
  • [20] Dual-energy chest radiography with a flat-panel digital detector:: Revealing calcified chest abnormalities
    Fischbach, F
    Freund, T
    Röttgen, R
    Engert, U
    Felix, R
    Ricke, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (06) : 1519 - 1524