GE a-Si flat-panel detector performance in industrial digital radiography

被引:0
|
作者
Mohr, GA [1 ]
Bueno, C
机构
[1] GE Inspect Technol, Cincinnati, OH 45215 USA
[2] GE Global Res, Niskayuna, NY 12309 USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The General Electric (GE) Revolution(TM) family of a-Si flat-panel digital X-ray detectors demonstrate outstanding sensitivity and resolution. The DXR-500 version, with 100-micron pixel pitch, has sufficient resolution to provide MTF over 20% at 5 lp/mm in a variety of industrial digital radiography applications. This detector exhibits linear performance over a wide range of exposure, from much less than 1 mR to over 60 mR incident dose at 80 W with 0.322 cm of A1 beam filtration. Noise performance is dominated by photon counting statistics, allowing effective frame averaging in challenging applications. The available image contrast from the new detectors depends on the X-ray energy selected, the dose captured, and the number of frames averaged. In practice, the desired image quality is balanced against the throughput requirements of the application. However, the total exposure time required with the detector typically is much less than that employed for industrial film applications, and can be as little as 10-20% that of the film exposure while maintaining comparable or improved image quality Thus, in film replacement applications, the dose efficiency of the detectors allows for extremely short exposure times and correspondingly high throughput in high-volume applications. This efficiency makes microfocus radiography practical when higher spatial resolution is required. These features enable inspection systems using these devices to provide excellent return on in vestment rates and short payback periods in a wide range of industrial applications.
引用
收藏
页码:631 / 633
页数:3
相关论文
共 50 条
  • [1] GE a-Si flat-panel detector performance in industrial digital radiography
    Mohr, Gregory A.
    Bueno, Clifford
    [J]. Insight: Non-Destructive Testing and Condition Monitoring, 2002, 44 (10): : 631 - 633
  • [2] Scan equalization digital radiography (SEDR) - Implementation with a flat-panel detector
    Liu, XM
    Shaw, CC
    Altunbas, MC
    Wang, TP
    [J]. Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1112 - 1120
  • [3] Digital thorax radiography: flat-panel detector or storage phosphor plates
    Schaefer-Prokop, C
    Uffmann, M
    Sailer, J
    Kabalan, N
    Herold, C
    Prokop, M
    [J]. RADIOLOGE, 2003, 43 (05): : 351 - 361
  • [4] A flat-panel detector digital radiography and a storage phosphor computed radiography: Screening for pneumoconioses
    Takashima, Yoshihiro
    Suganuma, Narufumi
    Sakurazawa, Hirofumi
    Itoh, Harumi
    Hirano, Harukazu
    Shida, Hisao
    Kusaka, Yukinori
    [J]. JOURNAL OF OCCUPATIONAL HEALTH, 2007, 49 (01) : 39 - 45
  • [5] Clinical comparison of imaging performance of a digital radiography system with a new flat-panel detector vs computed radiography
    Mildenberger, P
    Vogel, N
    Herber, SS
    Kaemmerer, M
    Thelen, M
    [J]. RADIOLOGY, 2000, 217 : 518 - 518
  • [6] Imaging characteristics of an amorphous silicon flat-panel detector for digital chest radiography
    Floyd, CE
    Warp, RJ
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Vargas-Voracek, R
    Ravin, CE
    [J]. RADIOLOGY, 2001, 218 (03) : 683 - 688
  • [7] High resolution flat-panel X-ray detector for digital radiography
    Park, JK
    Kang, SS
    Cha, BY
    Kim, JY
    Kim, SY
    Choi, HK
    Nam, SH
    [J]. Healthcom 2005: 7th International Workshop on Enterprise Networking and Computing in Healthcare Industry, Proceedings, 2005, : 359 - 363
  • [8] Optimum radiographic technique for chest radiography using a flat-panel digital detector
    Samei, E
    Dobbins, JT
    Chotas, HG
    Baydush, AH
    Floyd, CE
    Ravin, CE
    [J]. RADIOLOGY, 2002, 225 : 642 - 643
  • [9] Imaging performance of a direct digital flat-panel radiographic detector
    Kengyelics, SM
    Davies, AG
    Launders, JH
    Cowen, AR
    Richardson, DL
    Wilson, P
    [J]. RADIOLOGY, 1998, 209P : 358 - 358
  • [10] Chest radiography with a digital flat-panel detector: Experimental receiver operating characteristic analysis
    Metz, S
    Damoser, P
    Hollweck, R
    Roggel, R
    Engelke, C
    Woertler, K
    Renger, B
    Rummeny, EJ
    Link, TM
    [J]. RADIOLOGY, 2005, 234 (03) : 776 - 784