Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection

被引:57
|
作者
Kim, Ki-Seong [1 ,2 ]
Lim, Young-Jun [1 ,2 ]
Kim, Myung-Joo [1 ,2 ]
Kwon, Ho-Beom [1 ,2 ]
Yang, Jae-Ho [1 ,2 ]
Lee, Jai-Bong [1 ,2 ]
Yim, Soon-Ho [3 ]
机构
[1] Seoul Natl Univ, Dept Prosthodont, Sch Dent, Seoul 110749, South Korea
[2] Seoul Natl Univ, Dent Res Inst, Sch Dent, Seoul 110749, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Prosthodont,Inst Oral Hlth Sci, Seoul, South Korea
关键词
dental implants; implant-abutment interface; repeated tightening; settling effect; tightening torque; SCREW JOINT STABILITY; OSSEOINTEGRATED IMPLANTS; COMPLICATIONS; MISFIT;
D O I
10.1111/j.1600-0501.2010.02063.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Settling (embedment relaxation), which is the main cause for screw loosening, is developed by microroughness between implant and abutment metal surface. The objective of this study was to evaluate and compare the relationship between the level of applied torque and the settling of abutments into implants in external and internal implant-abutment connection. Material and methods: Five different implant-abutment connections were used (Ext, External butt joint + two-piece abutment; Int-H2, Internal hexagon + two-piece abutment; Int-H1, Internal hexagon + one-piece abutment; Int-O2, Internal octagon + two-piece abutment; Int-O1, Internal octagon + one-piece abutment). All abutments of each group were assembled and tightened with corresponding implants by a digital torque gauge. The total lengths of implant-abutment samples were measured at each torque (5, 10, 30 N cm and repeated 30 N cm with 10-min interval) by an electronic digital micrometer. The settling values were calculated by changes between the total lengths of implant-abutment samples. Results: All groups developed settling with repeated tightening. The Int-H2 group showed markedly higher settling for all instances of tightening torque and the Ext group was the lowest. Statistically significant differences were found in settling values between the groups and statistically significant increases were observed within each group at different tightening torques (P<0.05). After the second tightening of 30 N cm, repeated tightening showed almost constant settling values. Conclusions: Results from the present study suggested that to minimize the settling effect, abutment screws should be retightened at least twice at 30 N cm torque at a 10-min interval in all laboratory and clinical procedures.
引用
收藏
页码:834 / 839
页数:6
相关论文
共 50 条
  • [31] The survival of dental implants with different implant-abutment connection systems
    Szpak, Piotr
    Szymanska, Jolanta
    CURRENT ISSUES IN PHARMACY AND MEDICAL SCIENCES, 2016, 29 (01) : 11 - 13
  • [32] Bacterial Composition at the Implant-Abutment Connection under Loading in vivo
    Romanos, Georgios E.
    Biltucci, Mary Therese
    Kokaras, Alexis
    Paster, Bruce J.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 138 - 145
  • [33] THE ROLE OF IMPLANT-ABUTMENT CONNECTION IN PREVENTING BACTERIAL LEAKAGE: A REVIEW
    Candotto, V
    Gabrione, F.
    Oberti, L.
    Lento, D.
    Severino, M.
    JOURNAL OF BIOLOGICAL REGULATORS AND HOMEOSTATIC AGENTS, 2019, 33 (03): : 129 - 134
  • [34] Correlation between microleakage and screw loosening at implant-abutment connection
    Sahin, Cem
    Ayyildiz, Simel
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (01): : 35 - 38
  • [35] Comparative study of torque resistance and microgaps between a combined Octatorx-cone connection and an internal hexagon implant-abutment connection
    Khongkhunthian, Pathawee
    Khongkhunthian, Sakornratana
    Weerawatprachya, Winai
    Pongpat, Kanuengnit
    Aunmeungtong, Weerapan
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (05): : 420 - 424
  • [36] Micro-CT Evaluation of Microgaps at Implant-Abutment Connection
    Kowalski, Jakub
    Puszkarz, Adam K.
    Radwanski, Mateusz
    Sokolowski, Jerzy
    Cichomski, Michal
    Bourgi, Rim
    Hardan, Louis
    Sauro, Salvatore
    Lukomska-Szymanska, Monika
    MATERIALS, 2023, 16 (12)
  • [37] Longitudinal Observation of Micromotion upon Loading of Implant-Abutment Connection
    Yamashita, Kohei
    Kataoka, Yu
    Munakata, Motohiro
    Yamaguchi, Kikue
    Hayashi, Myu
    Baba, Daisuke
    BIOENGINEERING-BASEL, 2024, 11 (06):
  • [38] MICROSCOPE EVALUATION OF MICRO-GAPS AT IMPLANT-ABUTMENT CONNECTION
    Tartea, Daniel Adrian
    Popescu, Sanda Mihaela
    Manolea, Horia Octavian
    Ionescu, Mihaela
    Amarascu, Olimpia Marina
    Marasescu, Petre Costin
    Gingu, Oana
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2024, 16 (02): : 411 - 423
  • [39] Influence of connection geometry on dynamic micromotion at the implant-abutment interface
    Meng, Joe C.
    Everts, Joshua E.
    Qian, Fang
    Gratton, David G.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2007, 20 (06) : 623 - 625
  • [40] In Vitro Study of the Influence of the Type of Connection on the Fracture Load of Zirconia Abutments with Internal and External Implant-Abutment Connections
    Sailer, Irena
    Sailer, Thomas
    Stawarczyk, Bogna
    Jung, Ronald Ernst
    Haemmerle, Christoph Hans Franz
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2009, 24 (05) : 850 - 858