Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection

被引:57
|
作者
Kim, Ki-Seong [1 ,2 ]
Lim, Young-Jun [1 ,2 ]
Kim, Myung-Joo [1 ,2 ]
Kwon, Ho-Beom [1 ,2 ]
Yang, Jae-Ho [1 ,2 ]
Lee, Jai-Bong [1 ,2 ]
Yim, Soon-Ho [3 ]
机构
[1] Seoul Natl Univ, Dept Prosthodont, Sch Dent, Seoul 110749, South Korea
[2] Seoul Natl Univ, Dent Res Inst, Sch Dent, Seoul 110749, South Korea
[3] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Prosthodont,Inst Oral Hlth Sci, Seoul, South Korea
关键词
dental implants; implant-abutment interface; repeated tightening; settling effect; tightening torque; SCREW JOINT STABILITY; OSSEOINTEGRATED IMPLANTS; COMPLICATIONS; MISFIT;
D O I
10.1111/j.1600-0501.2010.02063.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: Settling (embedment relaxation), which is the main cause for screw loosening, is developed by microroughness between implant and abutment metal surface. The objective of this study was to evaluate and compare the relationship between the level of applied torque and the settling of abutments into implants in external and internal implant-abutment connection. Material and methods: Five different implant-abutment connections were used (Ext, External butt joint + two-piece abutment; Int-H2, Internal hexagon + two-piece abutment; Int-H1, Internal hexagon + one-piece abutment; Int-O2, Internal octagon + two-piece abutment; Int-O1, Internal octagon + one-piece abutment). All abutments of each group were assembled and tightened with corresponding implants by a digital torque gauge. The total lengths of implant-abutment samples were measured at each torque (5, 10, 30 N cm and repeated 30 N cm with 10-min interval) by an electronic digital micrometer. The settling values were calculated by changes between the total lengths of implant-abutment samples. Results: All groups developed settling with repeated tightening. The Int-H2 group showed markedly higher settling for all instances of tightening torque and the Ext group was the lowest. Statistically significant differences were found in settling values between the groups and statistically significant increases were observed within each group at different tightening torques (P<0.05). After the second tightening of 30 N cm, repeated tightening showed almost constant settling values. Conclusions: Results from the present study suggested that to minimize the settling effect, abutment screws should be retightened at least twice at 30 N cm torque at a 10-min interval in all laboratory and clinical procedures.
引用
收藏
页码:834 / 839
页数:6
相关论文
共 50 条
  • [21] The influence of implant-abutment connection on the screw loosening and microleakage
    Tsuruta, Katsuhiro
    Ayukawa, Yasunori
    Matsuzaki, Tatsuya
    Kihara, Masafumi
    Koyano, Kiyoshi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [22] Effects of tightening torque on screw stress and formation of implant-abutment microgaps: A finite element analysis
    Tonin, Bruna Santos Honorio
    He, Yiting
    Ye, Ning
    Chew, Hooi Pin
    Fok, Alex
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (06): : 882 - 889
  • [23] In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
    Kose, Onur Dincer
    Karatasli, Burcin
    Demircan, Sabit
    Kose, Taha Emre
    Cene, Erhan
    Aya, Serhan Aydjn
    Erdem, Mehmet Ali
    Cankaya, Abdulkadir Burak
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [24] Effect of fluid contamination on the reverse torque values of abutment screws at implant-abutment connections
    Koosha, Sara
    Toraji, Sedigheh
    Mostafavi, Azam S.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 123 (04): : 618 - 621
  • [25] Tightening torque of implant abutment using hand drivers against torque wrench and its effect on the internal surface of implant
    Sameera, Y.
    Rai, Rathika
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2020, 20 (02): : 180 - 185
  • [26] Influence of Abutment Fabrication Method on 3D Fit at the Implant-Abutment Connection
    Ramalho, Ilana
    Witek, Lukasz
    Coelho, Paulo G.
    Bergamo, Edmara
    Pegoraro, Luiz Fernando
    Bonfante, Estevam A.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2020, 33 (06) : 641 - 647
  • [27] Microleakage of bacteria in different implant-abutment assemblies: an in vitro study
    D'Ercole, Simonetta
    Tripodi, Domenico
    Marzo, Giuseppe
    Bernardi, Sara
    Continenza, Maria Adelaide
    Piattelli, Adriano
    Iaculli, Flavia
    Mummolo, Stefano
    JOURNAL OF APPLIED BIOMATERIALS & FUNCTIONAL MATERIALS, 2015, 13 (02): : E174 - E180
  • [28] The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study
    Bagegni, Aimen
    Spies, Benedikt C.
    Kern, Matthias
    Hazard, Derek
    Kohal, Ralf
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 113
  • [29] The influence of prosthetic crown height and implant-abutment connection design selection on the long-term implant-abutment stability: A laboratory study
    Bagegni, Aimen
    Spies, Benedikt C.
    Kern, Matthias
    Hazard, Derek
    Kohal, Ralf
    Journal of the Mechanical Behavior of Biomedical Materials, 2021, 113
  • [30] Essay 3: Biologic and mechanical principals of the implant-abutment connection
    不详
    INTERNATIONAL JOURNAL OF ESTHETIC DENTISTRY, 2011, 6 (02): : 246 - 251