Micro-CT Evaluation of Microgaps at Implant-Abutment Connection

被引:1
|
作者
Kowalski, Jakub [1 ]
Puszkarz, Adam K. [2 ]
Radwanski, Mateusz [3 ]
Sokolowski, Jerzy [1 ]
Cichomski, Michal [4 ]
Bourgi, Rim [5 ]
Hardan, Louis [5 ]
Sauro, Salvatore [6 ,7 ]
Lukomska-Szymanska, Monika [1 ]
机构
[1] Med Univ Lodz, Dept Gen Dent, PL-92213 Lodz, Poland
[2] Lodz Univ Technol, Inst Mat Sci Text & Polymer Composites, Fac Mat Technol & Text Design, 116 Zeromskiego St, PL-90924 Lodz, Poland
[3] Med Univ Lodz, Dept Endodont, PL-92213 Lodz, Poland
[4] Univ Lodz, Fac Chem, Dept Mat Technol & Chem, Pomorska 163, PL-90236 Lodz, Poland
[5] St Joseph Univ, Sch Dent, Dept Restorat Dent, Beirut 11072180, Lebanon
[6] Univ CEU Cardenal Herrera, Fac Cienciasde Salud, Dept Odontol, Dent Biomat & Minimally Invas Dent, C-Del Pozo SS-N, Valencia 46115, Spain
[7] I M Sechenov First Moscow State Med Univ, Dept Therapeut Dent, Moscow 119146, Russia
关键词
dental implant; microgap; micro-computed tomography; abutment; IN-VITRO ANALYSIS; DENTAL IMPLANTS; VERTICAL MISFIT; MARGINAL FIT; INTERFACE; TITANIUM; FATIGUE; LEAKAGE; DESIGN; ACCURACY;
D O I
10.3390/ma16124491
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The assessment of microgaps at the implant-abutment interface is an important factor that may influence clinical success. Thus, the aim of this study was to evaluate the size of microgaps between prefabricated and customised abutments (Astra Tech, Dentsply, York, PA, USA; Apollo Implants Components, Pabianice, Poland) mounted on a standard implant. The measurement of the microgap was performed using micro-computed tomography (MCT). Due to 15-degree rotation of samples, 24 microsections were obtained. Scans were performed at four levels established at the interface between the abutment and the implant neck. Moreover, the volume of the microgap was evaluated. The size of the microgap at all measured levels varied from 0.1 to 3.7 & mu;m for Astra and from 0.1 to 4.9 & mu;m for Apollo (p > 0.05). Moreover, 90% of the Astra specimens and 70% of the Apollo specimens did not exhibit any microgaps. The highest mean values of microgap size for both groups were detected at the lowest portion of the abutment (p > 0.05). Additionally, the average microgap volume was greater for Apollo than for Astra (p > 0.05). It can be concluded that most samples did not exhibit any microgaps. Furthermore, the linear and volumetric dimensions of microgaps observed at the interface between Apollo or Astra abutments and Astra implants were comparable. Additionally, all tested components presented microgaps (if any) that were clinically acceptable. However, the microgap size of the Apollo abutment was higher and more variable than that of the Astra one.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] MICROSCOPE EVALUATION OF MICRO-GAPS AT IMPLANT-ABUTMENT CONNECTION
    Tartea, Daniel Adrian
    Popescu, Sanda Mihaela
    Manolea, Horia Octavian
    Ionescu, Mihaela
    Amarascu, Olimpia Marina
    Marasescu, Petre Costin
    Gingu, Oana
    ROMANIAN JOURNAL OF ORAL REHABILITATION, 2024, 16 (02): : 411 - 423
  • [2] 3D EVALUATION OF MICROGAPS AT THE IMPLANT-ABUTMENT CONNECTION BEFORE AND AFTER THERMODYNAMIC CYCLING
    Cetin, Tugce
    Asian, Y. Umut
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (03) : e99 - e111
  • [3] The implant-abutment connection
    Nelson, Katja
    Zabler, Simon
    Wiest, Wolfram
    Schmelzeisen, Rainer
    Semper-Hogg, Wiebke
    IMPLANTOLOGIE, 2013, 21 (04): : 355 - 363
  • [4] Comparative study of torque resistance and microgaps between a combined Octatorx-cone connection and an internal hexagon implant-abutment connection
    Khongkhunthian, Pathawee
    Khongkhunthian, Sakornratana
    Weerawatprachya, Winai
    Pongpat, Kanuengnit
    Aunmeungtong, Weerapan
    JOURNAL OF PROSTHETIC DENTISTRY, 2015, 113 (05): : 420 - 424
  • [5] Influence of abutment and connection type on implant-abutment connection rigidity: an in vitro study
    Mendes, Teresa Almeida
    Vilhena, Luis Miguel
    Portugal, Jaime
    Carames, Joao
    Ramalho, Amilcar Lopes
    Lopes, Luis Pires
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2022, 63 (03): : 134 - 140
  • [6] Histology of a dental implant with a platform switched implant-abutment connection
    Degidi, Marco
    Perrotti, Vittoria
    Piattelli, Adriano
    Shibli, Jamil A.
    Iezzi, Giovanna
    JOURNAL OF OSSEOINTEGRATION, 2011, 3 (03) : 56 - 60
  • [7] Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
    Velez, Jorge
    Pelaez, Jesus
    Lopez-Suarez, Carlos
    Agustin-Panadero, Ruben
    Tobar, Celia
    Suarez, Maria J.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 13
  • [8] Marginal fit and microgaps of implant-abutment interface with internal anti-rotation configuration
    Tsuge, Takuma
    Hagiwara, Yoshiyuki
    Matsumura, Hideo
    DENTAL MATERIALS JOURNAL, 2008, 27 (01) : 29 - 34
  • [9] Evaluation of UCLA Implant-Abutment Sealing
    Ramos, Marcelo B.
    Pegoraro, Luiz F.
    Takamori, Esther
    Coelho, Paulo G.
    Silva, Thelma L.
    Bonfante, Estevam A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 113 - 120
  • [10] The influence of implant-abutment connection on the screw loosening and microleakage
    Tsuruta, Katsuhiro
    Ayukawa, Yasunori
    Matsuzaki, Tatsuya
    Kihara, Masafumi
    Koyano, Kiyoshi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4