Micro-CT Evaluation of Microgaps at Implant-Abutment Connection

被引:1
|
作者
Kowalski, Jakub [1 ]
Puszkarz, Adam K. [2 ]
Radwanski, Mateusz [3 ]
Sokolowski, Jerzy [1 ]
Cichomski, Michal [4 ]
Bourgi, Rim [5 ]
Hardan, Louis [5 ]
Sauro, Salvatore [6 ,7 ]
Lukomska-Szymanska, Monika [1 ]
机构
[1] Med Univ Lodz, Dept Gen Dent, PL-92213 Lodz, Poland
[2] Lodz Univ Technol, Inst Mat Sci Text & Polymer Composites, Fac Mat Technol & Text Design, 116 Zeromskiego St, PL-90924 Lodz, Poland
[3] Med Univ Lodz, Dept Endodont, PL-92213 Lodz, Poland
[4] Univ Lodz, Fac Chem, Dept Mat Technol & Chem, Pomorska 163, PL-90236 Lodz, Poland
[5] St Joseph Univ, Sch Dent, Dept Restorat Dent, Beirut 11072180, Lebanon
[6] Univ CEU Cardenal Herrera, Fac Cienciasde Salud, Dept Odontol, Dent Biomat & Minimally Invas Dent, C-Del Pozo SS-N, Valencia 46115, Spain
[7] I M Sechenov First Moscow State Med Univ, Dept Therapeut Dent, Moscow 119146, Russia
关键词
dental implant; microgap; micro-computed tomography; abutment; IN-VITRO ANALYSIS; DENTAL IMPLANTS; VERTICAL MISFIT; MARGINAL FIT; INTERFACE; TITANIUM; FATIGUE; LEAKAGE; DESIGN; ACCURACY;
D O I
10.3390/ma16124491
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The assessment of microgaps at the implant-abutment interface is an important factor that may influence clinical success. Thus, the aim of this study was to evaluate the size of microgaps between prefabricated and customised abutments (Astra Tech, Dentsply, York, PA, USA; Apollo Implants Components, Pabianice, Poland) mounted on a standard implant. The measurement of the microgap was performed using micro-computed tomography (MCT). Due to 15-degree rotation of samples, 24 microsections were obtained. Scans were performed at four levels established at the interface between the abutment and the implant neck. Moreover, the volume of the microgap was evaluated. The size of the microgap at all measured levels varied from 0.1 to 3.7 & mu;m for Astra and from 0.1 to 4.9 & mu;m for Apollo (p > 0.05). Moreover, 90% of the Astra specimens and 70% of the Apollo specimens did not exhibit any microgaps. The highest mean values of microgap size for both groups were detected at the lowest portion of the abutment (p > 0.05). Additionally, the average microgap volume was greater for Apollo than for Astra (p > 0.05). It can be concluded that most samples did not exhibit any microgaps. Furthermore, the linear and volumetric dimensions of microgaps observed at the interface between Apollo or Astra abutments and Astra implants were comparable. Additionally, all tested components presented microgaps (if any) that were clinically acceptable. However, the microgap size of the Apollo abutment was higher and more variable than that of the Astra one.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Fatigue Failure of Narrow Implants with Different Implant-Abutment Connection Designs
    Bordin, Dimorvan
    Witek, Lukasz
    Fardin, Vinicius P.
    Bonfante, Estevam A.
    Coelho, Paulo G.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (07): : 659 - 664
  • [32] In vitro assessment of connection strength and stability of internal implant-abutment connections
    Kofron, Michelle D.
    Carstens, Matthew
    Fu, Cong
    Wen, Hai Bo
    CLINICAL BIOMECHANICS, 2019, 65 : 92 - 99
  • [33] Implant-Abutment Connection Deformation After Prosthetic Procedures: An In Vitro Study
    Micarelli, Costanza
    Canullo, Luigi
    Iannello, Giuliano
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (03) : 282 - 286
  • [34] Bacterial Leakage and Microgap along Implant-Abutment Connection in Three Different Implant Systems
    Bajoghli, Farshad
    Amjadi, Mehrak
    Akouchekian, Mohadese
    Narimani, Tahmineh
    INTERNATIONAL JOURNAL OF ADVANCED BIOTECHNOLOGY AND RESEARCH, 2016, 7 (04): : 1284 - 1290
  • [35] Fracture resistance after implantoplasty in three implant-abutment connection designs
    Camps-Font, Octavi
    Gonzalez-Barnadas, Albert
    Mir-Mari, Javier
    Figueiredo, Rui
    Gay-Escoda, Cosme
    Valmaseda-Castellon, Eduard
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2020, 25 (05): : E691 - E699
  • [36] Influence of the implant-abutment connection design and diameter on the screw joint stability
    Shin, Hyon-Mo
    Huh, Jung-Bo
    Yun, Mi-Jeong
    Jeon, Young-Chan
    Chang, Brian Myung
    Jeong, Chang-Mo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (02): : 126 - 132
  • [37] Implant-Abutment Connection Designs for Anterior Crowns: Reliability and Failure Modes
    Machado, Lucas S.
    Bonfante, Estevam A.
    Anchieta, Rodolfo B.
    Yamaguchi, Satoshi
    Coelho, Paulo G.
    IMPLANT DENTISTRY, 2013, 22 (05) : 540 - 545
  • [38] Stability of implant-abutment connection in three different systems after fatigue test
    Bajoghli, Farshad
    Sabouhi, Mohmoud
    Pourali, Mohamad
    Davoudi, Amin
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (04) : 338 - 342
  • [39] Pull-off resistance of a screwless implant-abutment connection and surface evaluation after cyclic loading
    Alevizakos, Vasilios
    Mosch, Richard
    Mitov, Gergo
    Othman, Ahmed
    von See, Constantin
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (03): : 152 - 159
  • [40] The Impact of Implant-Abutment Connection on Clinical Outcomes and Microbial Colonization: A Narrative Review
    Lauritano, Dorina
    Moreo, Giulia
    Lucchese, Alberta
    Viganoni, Chiara
    Limongelli, Luisa
    Carinci, Francesco
    MATERIALS, 2020, 13 (05)