MICROSCOPE EVALUATION OF MICRO-GAPS AT IMPLANT-ABUTMENT CONNECTION

被引:1
|
作者
Tartea, Daniel Adrian [1 ]
Popescu, Sanda Mihaela [2 ]
Manolea, Horia Octavian [3 ]
Ionescu, Mihaela [4 ]
Amarascu, Olimpia Marina [5 ]
Marasescu, Petre Costin [6 ]
Gingu, Oana [7 ]
机构
[1] Univ Med & Pharm Craiova, Craiova, Romania
[2] Univ Med & Pharm Craiova, Fac Dent Med, Dept Oral Rehabil, Craiova, Romania
[3] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Mat, Craiova, Romania
[4] Univ Med & Pharm Craiova, Fac Dent Med, Dept Med Informat & Biostat, Craiova, Romania
[5] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Morphol, Craiova, Romania
[6] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Technol, Craiova, Romania
[7] Univ Craiova, Fac Mech, Dept Engn & Management Technol Syst, Craiova, Romania
来源
关键词
dental implant custom abutments; CAD/CAM; dental technology; micro-gap; implant-abutment interface; vertical fit; IN-VITRO EVALUATION; INTERNAL HEXAGON; DENTAL IMPLANTS; ZIRCONIA; TITANIUM; FIT; ACCURACY;
D O I
10.6261/RJOR.2024.2.16.36
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The use of custom CAD/CAM abutments in implant restorations has become a reality, but there are questions about the existence of micro-gaps at the implant-abutment junction larger than those of the original standard stock abutments. The purpose of this study was to compare dimensions of the micro-gaps between four types of implant abutments (original dental implant stock abutments, compatible dental implant stock abutments, and two types of customized CAD/CAM dental implant abutments) all with the same connection of Bredent Sky system mounted on a standard implant. Material and Method: Micro-gap measurements were made on four groups of Titanium abutments: 1) original dental implant stock abutments - industrial machined, 2) compatible dental implant stock abutments - industrial machined and 3) and 4) compatible customized CAD/CAM dental implant abutments - non-industrial milled with two different parameters in hyperDENT CAM software and Paragon Tools. The Nikon SMZ745T stereomicroscope was used to measure the micro-gaps of each dental implant abutment and results were statistically analyzed. Results: The micro-gaps measured on implant-abutments junction did not show significant differences between original abutment, and the three types of compatible abutments. Conclusions: No significant differences of the micro-gap at the implant-abutment junction were observed between the original implant abutments and compatible abutments, and customized abutments. Micro-gap dimensions were within the clinically accepted limit and the use of custom CAD/CAM dental implant abutments is reliable .
引用
收藏
页码:411 / 423
页数:13
相关论文
共 50 条
  • [1] Micro-CT Evaluation of Microgaps at Implant-Abutment Connection
    Kowalski, Jakub
    Puszkarz, Adam K.
    Radwanski, Mateusz
    Sokolowski, Jerzy
    Cichomski, Michal
    Bourgi, Rim
    Hardan, Louis
    Sauro, Salvatore
    Lukomska-Szymanska, Monika
    MATERIALS, 2023, 16 (12)
  • [2] The implant-abutment connection
    Nelson, Katja
    Zabler, Simon
    Wiest, Wolfram
    Schmelzeisen, Rainer
    Semper-Hogg, Wiebke
    IMPLANTOLOGIE, 2013, 21 (04): : 355 - 363
  • [3] Influence of abutment and connection type on implant-abutment connection rigidity: an in vitro study
    Mendes, Teresa Almeida
    Vilhena, Luis Miguel
    Portugal, Jaime
    Carames, Joao
    Ramalho, Amilcar Lopes
    Lopes, Luis Pires
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2022, 63 (03): : 134 - 140
  • [4] Histology of a dental implant with a platform switched implant-abutment connection
    Degidi, Marco
    Perrotti, Vittoria
    Piattelli, Adriano
    Shibli, Jamil A.
    Iezzi, Giovanna
    JOURNAL OF OSSEOINTEGRATION, 2011, 3 (03) : 56 - 60
  • [5] Influence of Implant Connection, Abutment Design and Screw Insertion Torque on Implant-Abutment Misfit
    Velez, Jorge
    Pelaez, Jesus
    Lopez-Suarez, Carlos
    Agustin-Panadero, Ruben
    Tobar, Celia
    Suarez, Maria J.
    JOURNAL OF CLINICAL MEDICINE, 2020, 9 (08) : 1 - 13
  • [6] Evaluation of UCLA Implant-Abutment Sealing
    Ramos, Marcelo B.
    Pegoraro, Luiz F.
    Takamori, Esther
    Coelho, Paulo G.
    Silva, Thelma L.
    Bonfante, Estevam A.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 113 - 120
  • [7] The influence of implant-abutment connection on the screw loosening and microleakage
    Tsuruta, Katsuhiro
    Ayukawa, Yasunori
    Matsuzaki, Tatsuya
    Kihara, Masafumi
    Koyano, Kiyoshi
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2018, 4
  • [8] Axial displacements in external and internal implant-abutment connection
    Lee, Ji-Hye
    Kim, Dae-Gon
    Park, Chan-Jin
    Cho, Lee-Ra
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (02) : E83 - E89
  • [9] Digital evaluation of axial displacement by implant-abutment connection type: An in vitro study
    Kim, Sung-Jun
    Son, KeunBaDa
    Lee, Kyu-Bok
    JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (05): : 388 - 394
  • [10] Implant-abutment connection as contributing factor to peri-implant diseases
    Koutouzis, Theofilos
    PERIODONTOLOGY 2000, 2019, 81 (01) : 152 - 166