MICROSCOPE EVALUATION OF MICRO-GAPS AT IMPLANT-ABUTMENT CONNECTION

被引:1
|
作者
Tartea, Daniel Adrian [1 ]
Popescu, Sanda Mihaela [2 ]
Manolea, Horia Octavian [3 ]
Ionescu, Mihaela [4 ]
Amarascu, Olimpia Marina [5 ]
Marasescu, Petre Costin [6 ]
Gingu, Oana [7 ]
机构
[1] Univ Med & Pharm Craiova, Craiova, Romania
[2] Univ Med & Pharm Craiova, Fac Dent Med, Dept Oral Rehabil, Craiova, Romania
[3] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Mat, Craiova, Romania
[4] Univ Med & Pharm Craiova, Fac Dent Med, Dept Med Informat & Biostat, Craiova, Romania
[5] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Morphol, Craiova, Romania
[6] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Technol, Craiova, Romania
[7] Univ Craiova, Fac Mech, Dept Engn & Management Technol Syst, Craiova, Romania
来源
关键词
dental implant custom abutments; CAD/CAM; dental technology; micro-gap; implant-abutment interface; vertical fit; IN-VITRO EVALUATION; INTERNAL HEXAGON; DENTAL IMPLANTS; ZIRCONIA; TITANIUM; FIT; ACCURACY;
D O I
10.6261/RJOR.2024.2.16.36
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The use of custom CAD/CAM abutments in implant restorations has become a reality, but there are questions about the existence of micro-gaps at the implant-abutment junction larger than those of the original standard stock abutments. The purpose of this study was to compare dimensions of the micro-gaps between four types of implant abutments (original dental implant stock abutments, compatible dental implant stock abutments, and two types of customized CAD/CAM dental implant abutments) all with the same connection of Bredent Sky system mounted on a standard implant. Material and Method: Micro-gap measurements were made on four groups of Titanium abutments: 1) original dental implant stock abutments - industrial machined, 2) compatible dental implant stock abutments - industrial machined and 3) and 4) compatible customized CAD/CAM dental implant abutments - non-industrial milled with two different parameters in hyperDENT CAM software and Paragon Tools. The Nikon SMZ745T stereomicroscope was used to measure the micro-gaps of each dental implant abutment and results were statistically analyzed. Results: The micro-gaps measured on implant-abutments junction did not show significant differences between original abutment, and the three types of compatible abutments. Conclusions: No significant differences of the micro-gap at the implant-abutment junction were observed between the original implant abutments and compatible abutments, and customized abutments. Micro-gap dimensions were within the clinically accepted limit and the use of custom CAD/CAM dental implant abutments is reliable .
引用
收藏
页码:411 / 423
页数:13
相关论文
共 50 条
  • [41] Analysis of Implant Strength After Implantoplasty in Three Implant-Abutment Connection Designs: An In Vitro Study
    Alexandre Gehrke, Sergio
    Aramburu Junior, Jaime Sarda
    Dedavid, Berenice Anina
    Shibli, Jamil Awad
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (03) : E65 - E70
  • [42] Effect of Different Implant-Abutment Connection Materials on the Fracture Resistance of Zirconia Abutments
    AlAmar, Mohammed
    Alqahtani, Fawaz
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (02) : 88 - 92
  • [43] The Mechanical Behavior of a Screwless Morse Taper Implant-Abutment Connection: An In Vitro Study
    Bagegni, Aimen
    Weihrauch, Vincent
    Vach, Kirstin
    Kohal, Ralf
    MATERIALS, 2022, 15 (09)
  • [44] Stability of Implant-Abutment Connection After Using the Rescue Kit: An In Vitro Study
    Sprenger, Achim
    Gutauskas, Kristupas
    Filippi, Andreas
    Rosentritt, Martin
    Kuehl, Sebastian
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2018, 33 (06) : 1274 - 1278
  • [45] Effect of Serrating Abutment-Implant Mating Surface on Torque Stability of Implant-Abutment Connection, Before and After Cyclic Loading
    Rezayani, Vida
    Alikhasi, Marzieh
    Monzavi, Abbas
    JOURNAL OF ORAL IMPLANTOLOGY, 2020, 46 (06) : 555 - 561
  • [46] Evaluation of different debridement strategies for implant-abutment connections: An in vitro
    Lang, Lilly K.
    Karl, Matthias
    Klaer, Virgilia
    JOURNAL OF PROSTHETIC DENTISTRY, 2023, 130 (05): : 738.e1 - 738.e8
  • [47] Comparison of Ss penetration through various implant-abutment connection mechanisms.
    Muftu, A
    Mulcahy, HL
    Chapman, RJ
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 585 - 585
  • [48] Effects of different torque levels on the implant-abutment interface in a conical internal connection
    Alexandre Gehrke, Sergio
    Shibli, Jamil Awad
    Aramburu Junior, Jaime Sarda
    Mate Sanchez de Val, Jose Eduardo
    Luis Calvo-Girardo, Jose
    Dedavid, Berenice Anina
    BRAZILIAN ORAL RESEARCH, 2016, 30 (01):
  • [49] Adaptation of different types of implant-abutment connection: a retrospective histological study.
    Pompa, G
    Iezzi, G
    Petrone, G
    Ripari, F
    Scarano, A
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B261 - B261
  • [50] In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection
    Khorshidi, Hooman
    Raoofi, Saeed
    Moattari, Afagh
    Bagheri, Atoosa
    Kalantari, Mohammad Hassan
    INTERNATIONAL JOURNAL OF BIOMATERIALS, 2016, 2016