The Mechanical Behavior of a Screwless Morse Taper Implant-Abutment Connection: An In Vitro Study

被引:7
|
作者
Bagegni, Aimen [1 ]
Weihrauch, Vincent [1 ]
Vach, Kirstin [2 ]
Kohal, Ralf [1 ]
机构
[1] Univ Freiburg, Med Ctr, Ctr Dent Med, Dept Prosthet Dent,Fac Med, Hugstetter Str 55, D-79106 Freiburg, Germany
[2] Univ Freiburg, Med Ctr, Inst Med Biometry & Stat, Fac Med, D-79106 Freiburg, Germany
关键词
screwless; implant-abutment connection; conical; Morse taper; pull-off force; CROWN HEIGHT; STRESS-DISTRIBUTION; RESTORATIONS; COMPLICATIONS; PERFORMANCE; RESISTANCE; FORCE; RATIO;
D O I
10.3390/ma15093381
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The use of screwless Morse taper implant-abutment connections (IAC) might facilitate the clinician's work by eliminating the mechanical complications associated with the retention screw. The aim of this study is to evaluate the effect of artificial chewing on the long-term stability of screwless Morse taper IACs. Thirty-two implant abutments restored with an upper central incisor zirconia crown were used and divided into four groups according to the implant-abutment assembling manner (C1,H: screw retained (20 Ncm); C2: tapped; or C3: torqued (20 Ncm; the screws were removed before the dynamic loading)). All specimens were subjected to a cyclic loading (98 N) for 10 million chewing cycles. The survived samples were exposed to a pull-off force until failure/disassembling of the connection. All the samples revealed a 100% survival. Regarding the pull-off test, the screw-retained internal hexagonal IAC revealed significantly higher resistance to failure/disassembling (769.6 N) than screwless conical IACs (171.6 N-246 N) (p < 0.0001). The retention forces in the Morse taper groups were not significantly different (p > 0.05). The screw-retained hexagonal IAC showed the highest retention stability. The screw preload/retention in the conical IAC was lost over time in the group where the screws were kept in place during loading. Nevertheless, the screwless Morse taper IACs were stable for an extended service time and might represent a valid form of treatment for single-tooth replacement.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Mechanical resistance of screwless morse taper and screw-retained implant-abutment connections
    Ugurel, Cihan Sadi
    Steiner, Martin
    Isik-Ozkol, Gul
    Kutay, Omer
    Kern, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (02) : 137 - 142
  • [2] The Bacterial Sealing Capacity of Morse Taper Implant-Abutment Systems in Vitro
    Ranieri, Rogerio
    Ferreira, Andreia
    Souza, Emmanuel
    Arcoverde, Joao
    Dametto, Fabio
    Gade-Neto, Cicero
    Seabra, Flavio
    Sarmento, Carlos
    JOURNAL OF PERIODONTOLOGY, 2015, 86 (05) : 696 - 702
  • [3] Mechanical Resistance of a 2.9-mm-Diameter Dental Implant With a Morse-Taper Implant-Abutment Connection
    Alberti, Alice
    Corbella, Stefano
    Francetti, Luca
    JOURNAL OF ORAL IMPLANTOLOGY, 2023, 49 (03) : 323 - 329
  • [4] The mechanical and clinical influences of prosthetic index structure in Morse taper implant-abutment connection: a scoping review
    Liheng Shen
    Chengzhi Dong
    Jianping Chen
    Xiaolei Bai
    Fan Yang
    Linhong Wang
    BMC Oral Health, 23
  • [5] The mechanical and clinical influences of prosthetic index structure in Morse taper implant-abutment connection: a scoping review
    Shen, Liheng
    Dong, Chengzhi
    Chen, Jianping
    Bai, Xiaolei
    Yang, Fan
    Wang, Linhong
    BMC ORAL HEALTH, 2023, 23 (01)
  • [6] Sealing efficacy of Morse-taper implant-abutment connection: an in vitro study using RT-PCR and turbidometry
    Alberti, Alice
    Corbella, Stefano
    Conti, Ilaria
    Taschieri, Silvio
    Francetti, Luca
    DENTAL CADMOS, 2022, 90 (06) : 450 - 456
  • [7] Microbial leakage through the implant-abutment interface of morse taper implants in vitro
    Aloise, Joao Pedro
    Curcio, Ricardo
    Laporta, Marcia Zorello
    Rossi, Liliane
    Alvares da Silva, Adriana Madeira
    Rapoport, Abrao
    CLINICAL ORAL IMPLANTS RESEARCH, 2010, 21 (03) : 328 - 335
  • [8] In Vitro Evaluation of Bacterial Leakage at Implant-Abutment Connection: An 11-Degree Morse Taper Compared to a Butt Joint Connection
    Khorshidi, Hooman
    Raoofi, Saeed
    Moattari, Afagh
    Bagheri, Atoosa
    Kalantari, Mohammad Hassan
    INTERNATIONAL JOURNAL OF BIOMATERIALS, 2016, 2016
  • [9] Influence of abutment and connection type on implant-abutment connection rigidity: an in vitro study
    Mendes, Teresa Almeida
    Vilhena, Luis Miguel
    Portugal, Jaime
    Carames, Joao
    Ramalho, Amilcar Lopes
    Lopes, Luis Pires
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2022, 63 (03): : 134 - 140
  • [10] Clinical Comparison of Screw-Retained and Screwless Morse Taper Implant-Abutment Connections: One-Year Postloading Results
    Geckili, Esma
    Geckili, Onur
    Bilhan, Hakan
    Kutay, Omer
    Bilgin, Tayfun
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (05) : 1123 - 1131