MICROSCOPE EVALUATION OF MICRO-GAPS AT IMPLANT-ABUTMENT CONNECTION

被引:1
|
作者
Tartea, Daniel Adrian [1 ]
Popescu, Sanda Mihaela [2 ]
Manolea, Horia Octavian [3 ]
Ionescu, Mihaela [4 ]
Amarascu, Olimpia Marina [5 ]
Marasescu, Petre Costin [6 ]
Gingu, Oana [7 ]
机构
[1] Univ Med & Pharm Craiova, Craiova, Romania
[2] Univ Med & Pharm Craiova, Fac Dent Med, Dept Oral Rehabil, Craiova, Romania
[3] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Mat, Craiova, Romania
[4] Univ Med & Pharm Craiova, Fac Dent Med, Dept Med Informat & Biostat, Craiova, Romania
[5] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Morphol, Craiova, Romania
[6] Univ Med & Pharm Craiova, Fac Dent Med, Dept Dent Technol, Craiova, Romania
[7] Univ Craiova, Fac Mech, Dept Engn & Management Technol Syst, Craiova, Romania
来源
关键词
dental implant custom abutments; CAD/CAM; dental technology; micro-gap; implant-abutment interface; vertical fit; IN-VITRO EVALUATION; INTERNAL HEXAGON; DENTAL IMPLANTS; ZIRCONIA; TITANIUM; FIT; ACCURACY;
D O I
10.6261/RJOR.2024.2.16.36
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The use of custom CAD/CAM abutments in implant restorations has become a reality, but there are questions about the existence of micro-gaps at the implant-abutment junction larger than those of the original standard stock abutments. The purpose of this study was to compare dimensions of the micro-gaps between four types of implant abutments (original dental implant stock abutments, compatible dental implant stock abutments, and two types of customized CAD/CAM dental implant abutments) all with the same connection of Bredent Sky system mounted on a standard implant. Material and Method: Micro-gap measurements were made on four groups of Titanium abutments: 1) original dental implant stock abutments - industrial machined, 2) compatible dental implant stock abutments - industrial machined and 3) and 4) compatible customized CAD/CAM dental implant abutments - non-industrial milled with two different parameters in hyperDENT CAM software and Paragon Tools. The Nikon SMZ745T stereomicroscope was used to measure the micro-gaps of each dental implant abutment and results were statistically analyzed. Results: The micro-gaps measured on implant-abutments junction did not show significant differences between original abutment, and the three types of compatible abutments. Conclusions: No significant differences of the micro-gap at the implant-abutment junction were observed between the original implant abutments and compatible abutments, and customized abutments. Micro-gap dimensions were within the clinically accepted limit and the use of custom CAD/CAM dental implant abutments is reliable .
引用
收藏
页码:411 / 423
页数:13
相关论文
共 50 条
  • [31] Fracture resistance after implantoplasty in three implant-abutment connection designs
    Camps-Font, Octavi
    Gonzalez-Barnadas, Albert
    Mir-Mari, Javier
    Figueiredo, Rui
    Gay-Escoda, Cosme
    Valmaseda-Castellon, Eduard
    MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2020, 25 (05): : E691 - E699
  • [32] Influence of the implant-abutment connection design and diameter on the screw joint stability
    Shin, Hyon-Mo
    Huh, Jung-Bo
    Yun, Mi-Jeong
    Jeon, Young-Chan
    Chang, Brian Myung
    Jeong, Chang-Mo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (02): : 126 - 132
  • [33] Implant-Abutment Connection Designs for Anterior Crowns: Reliability and Failure Modes
    Machado, Lucas S.
    Bonfante, Estevam A.
    Anchieta, Rodolfo B.
    Yamaguchi, Satoshi
    Coelho, Paulo G.
    IMPLANT DENTISTRY, 2013, 22 (05) : 540 - 545
  • [34] Stability of implant-abutment connection in three different systems after fatigue test
    Bajoghli, Farshad
    Sabouhi, Mohmoud
    Pourali, Mohamad
    Davoudi, Amin
    THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (04) : 338 - 342
  • [35] Pull-off resistance of a screwless implant-abutment connection and surface evaluation after cyclic loading
    Alevizakos, Vasilios
    Mosch, Richard
    Mitov, Gergo
    Othman, Ahmed
    von See, Constantin
    JOURNAL OF ADVANCED PROSTHODONTICS, 2021, 13 (03): : 152 - 159
  • [36] The Impact of Implant-Abutment Connection on Clinical Outcomes and Microbial Colonization: A Narrative Review
    Lauritano, Dorina
    Moreo, Giulia
    Lucchese, Alberta
    Viganoni, Chiara
    Limongelli, Luisa
    Carinci, Francesco
    MATERIALS, 2020, 13 (05)
  • [37] In Vitro Analysis of the Implant-Abutment Interface Connection and Bacterial Infiltration in Two Extraoral Implant Models
    de Souza, Ricardo Salgado
    Suffredini, Ivana Barbosa
    Cortizo, Daniela Lattuf
    Larsson, Anna
    Nannmark, Ulf
    Dib, Luciano Lauria
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (01) : 63 - 69
  • [38] COMMENTARY. radiographical evaluation of the gap at the implant-abutment interface
    Tarnow, Dennis
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2010, 22 (04) : 251 - 251
  • [39] Assessment of Leakage at the Implant-Abutment Connection Using a New Gas Flow Method
    Fauroux, Marie-Alix
    Levallois, Bernard
    Yachouh, Jacques
    Torres, Jacques-Henri
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2012, 27 (06) : 1409 - 1412
  • [40] Mechanics of the implant-abutment connection: An 8-degree taper compared to a butt joint connection
    Merz, BR
    Hunenbart, S
    Belser, UC
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2000, 15 (04) : 519 - 526