Longitudinal Observation of Micromotion upon Loading of Implant-Abutment Connection

被引:0
|
作者
Yamashita, Kohei [1 ]
Kataoka, Yu [2 ,3 ]
Munakata, Motohiro [4 ]
Yamaguchi, Kikue [4 ]
Hayashi, Myu [5 ]
Baba, Daisuke [6 ]
机构
[1] Showa Univ, Grad Sch Dent, Dept Implant Dent, 2-1-1 Kita Senzoku,Ota Ku, Tokyo 1458515, Japan
[2] Showa Univ, Sch Dent, Dept Dent Educ, 1-5-8 Hatanodai,Shinagawa Ku, Tokyo 1428555, Japan
[3] Showa Univ, Dept Biomat & Engn, Sch Dent, 1-5-8 Hatanodai,Shinagawa Ku, Tokyo 1428555, Japan
[4] Showa Univ, Sch Dent, Dept Implant Dent, 2-1-1 Kita Senzoku,Ohta Ku, Tokyo 1458515, Japan
[5] Showa Univ, Sch Dent, Dept Oral Hlth Management, Div Oral Funct Management, 2-1-1 Kita Senzoku,Ota Ku, Tokyo 1458515, Japan
[6] Showa Univ, Sch Dent, Dept Dent Lab, 2-1-1 Kita Senzoku,Ota Ku, Tokyo 1458515, Japan
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 06期
关键词
implant loading; micromotion; peri-implantitis; implant-abutment connection; removal torque;
D O I
10.3390/bioengineering11060582
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
While technological advances have made implants a good treatment option with a good long-term prognosis, peri-implantitis, which results in alveolar bone resorption around implants, has been observed in some cases. Micromotion at the implant abutment connection can cause peri-implantitis. However, the temporal progression of micromotion upon loading remains unclear. Therefore, we aimed to longitudinally measure micromotion upon loading application on an implant. Implants with Morse-tapered connections were prepared. Custom titanium abutments were fabricated and tightened onto implant bodies at 35 N. A 100 N vertical load was applied for 200,000 cycles. Micromotion was measured when the load was applied, as was the total implant length and removal torque before and after loading. The micromotion was measured from the position data of the jig of the testing machine during loading. The average removal torque was 30.67 N after 10 min of tightening and 27.95 N after loading, indicating a decrease due to loading. The implant length reduced by 3.6 mu m under the load. The average micromotion was 0.018 mm at 2 cycles, 0.016 mm at 100,000 cycles, and 0.0157 mm at 200,000 cycles, indicating implant length reduction under the load but not reaching 0. The micromotion between the implant and abutment under a cyclic load decreased over time but did not completely cease. These results highlight the relationship between micromotion and loading, underscoring the importance of careful monitoring and management to mitigate potential complications, such as peri-implantitis, and ensure optimal performance and durability of the implant.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Effect of Cyclic Loading on Micromotion at the Implant-Abutment Interface
    Karl, Matthias
    Taylor, Thomas D.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (06) : 1292 - 1302
  • [2] Influence of connection geometry on dynamic micromotion at the implant-abutment interface
    Meng, Joe C.
    Everts, Joshua E.
    Qian, Fang
    Gratton, David G.
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2007, 20 (06) : 623 - 625
  • [3] The implant-abutment connection
    Nelson, Katja
    Zabler, Simon
    Wiest, Wolfram
    Schmelzeisen, Rainer
    Semper-Hogg, Wiebke
    IMPLANTOLOGIE, 2013, 21 (04): : 355 - 363
  • [4] Parameters Determining Micromotion at the Implant-Abutment Interface
    Karl, Matthias
    Taylor, Thomas D.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (06) : 1338 - 1347
  • [5] Bacterial Composition at the Implant-Abutment Connection under Loading in vivo
    Romanos, Georgios E.
    Biltucci, Mary Therese
    Kokaras, Alexis
    Paster, Bruce J.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (01) : 138 - 145
  • [6] Correlation Between Micromotion and Gap Formation at the Implant-Abutment Interface
    Grobecker-Karl, Tanja
    Karl, Matthias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2017, 30 (02) : 150 - 152
  • [7] Micromotion and dynamic fatigue properties of the denial implant-abutment interface
    Gratton, DG
    Aquilino, SA
    Stanford, CM
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (01): : 47 - 52
  • [8] Influence of abutment and connection type on implant-abutment connection rigidity: an in vitro study
    Mendes, Teresa Almeida
    Vilhena, Luis Miguel
    Portugal, Jaime
    Carames, Joao
    Ramalho, Amilcar Lopes
    Lopes, Luis Pires
    REVISTA PORTUGUESA DE ESTOMATOLOGIA MEDICINA DENTARIA E CIRURGIA MAXILOFACIAL, 2022, 63 (03): : 134 - 140
  • [9] Micromotion of implant-abutment interfaces (IAI) after loading: correlation of finite element analysis with in vitro performances
    Li, Zhi
    Gao, Shanshan
    Chen, Hongyu
    Ma, Ruiyang
    Wu, Tingting
    Yu, Haiyang
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2019, 57 (05) : 1133 - 1144
  • [10] Micromotion of implant-abutment interfaces (IAI) after loading: correlation of finite element analysis with in vitro performances
    Zhi Li
    Shanshan Gao
    Hongyu Chen
    Ruiyang Ma
    Tingting Wu
    Haiyang Yu
    Medical & Biological Engineering & Computing, 2019, 57 : 1133 - 1144