Effect of anode/filter combination on the dose and image quality of a digital mammography system based on an amorphous selenium detector

被引:0
|
作者
Baldelli, Paola [1 ]
Phelan, Niall [1 ]
Egan, Gillian [1 ]
机构
[1] Breastcheck, Dublin, Ireland
来源
关键词
digital mammography; image quality; contrast-to-noise ratio;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A comparison of image quality and glandular breast dose was carried out on two digital mammography systems using alpha-Se flat panel detectors. The two digital mammography systems currently available from Hologic were compared. The original system utilises Mo /Mo and Mo/Rh as target/filter combinations, while the new system uses W/Rh and W/Ag. Images of mammography phantoms with different simulated breast thickness and various glandular compositions, was calculated and the AGD needed to visualize a detail with a CNR of 5 was estimated. For each phantom thickness and target/filter combination, there is an optimum voltage which maximizes the AGD. Using the Tungsten tube system there is a dose redcution of 16% at 4cm and 5cm, and 35% for 6 cm compared with the dose needed with the Mo/Mo combination.
引用
下载
收藏
页码:716 / 723
页数:8
相关论文
共 50 条
  • [1] Investigation of the effect of anode/filter materials on the dose and image quality of a digital mammography system based on an amorphous selenium flat panel detector
    Baldelli, P.
    Phelan, N.
    Egan, G.
    BRITISH JOURNAL OF RADIOLOGY, 2010, 83 (988): : 290 - 295
  • [2] Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system
    Paula Toroi
    Federica Zanca
    Kenneth C. Young
    Chantal van Ongeval
    Guy Marchal
    Hilde Bosmans
    European Radiology, 2007, 17 : 2368 - 2375
  • [3] Experimental investigation on the choice of the tungsten/rhodium anode/filter combination for an amorphous selenium-based digital mammography system
    Toroi, Paula
    Zanca, Federica
    Young, Kenneth C.
    van Ongeval, Chantal
    Marchal, Guy
    Bosmans, Hilde
    EUROPEAN RADIOLOGY, 2007, 17 (09) : 2368 - 2375
  • [4] Optimizing the anode-filter combination in the sense of image quality and average glandular dose in digital mammography
    Varjonen, Mari
    Stroemmer, Pekka
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [5] Effect of filter on average glandular dose and image quality in digital mammography
    Songsaeng, C.
    Krisanachinda, A.
    Theerakul, K.
    13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [6] Effect of anode/filter combination on average glandular dose in mammography
    Biegala, Michal
    Jakubowska, Teresa
    Markowska, Karolina
    JOURNAL OF MEDICAL PHYSICS, 2015, 40 (01) : 45 - 51
  • [7] Radiographic techniques for digital mammography with an amorphous selenium detector
    Peck, D
    Flynn, M
    Dodge, C
    Swinford, A
    MEDICAL PHYSICS, 2003, 30 (06) : 1406 - 1406
  • [8] Detector evaluation of a prototype amorphous selenium-based full field digital mammography system
    Jesneck, JL
    Saunders, RS
    Samei, E
    Xia, JQ
    Lo, JY
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 478 - 485
  • [9] IMAGE QUALITY OF A DIGITAL CHEST RADIOGRAPHY SYSTEM BASED ON A SELENIUM DETECTOR
    NEITZEL, U
    MAACK, I
    GUNTHERKOHFAHL, S
    MEDICAL PHYSICS, 1994, 21 (04) : 509 - 516
  • [10] IMAGE QUALITY OF A DIGITAL CHEST RADIOGRAPHY SYSTEM BASED ON A SELENIUM DETECTOR
    NEITZEL, U
    MAACK, I
    GUENTHERKOHFAHL, S
    RADIOLOGY, 1992, 185 : 158 - 159