Effect of anode/filter combination on the dose and image quality of a digital mammography system based on an amorphous selenium detector

被引:0
|
作者
Baldelli, Paola [1 ]
Phelan, Niall [1 ]
Egan, Gillian [1 ]
机构
[1] Breastcheck, Dublin, Ireland
来源
关键词
digital mammography; image quality; contrast-to-noise ratio;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A comparison of image quality and glandular breast dose was carried out on two digital mammography systems using alpha-Se flat panel detectors. The two digital mammography systems currently available from Hologic were compared. The original system utilises Mo /Mo and Mo/Rh as target/filter combinations, while the new system uses W/Rh and W/Ag. Images of mammography phantoms with different simulated breast thickness and various glandular compositions, was calculated and the AGD needed to visualize a detail with a CNR of 5 was estimated. For each phantom thickness and target/filter combination, there is an optimum voltage which maximizes the AGD. Using the Tungsten tube system there is a dose redcution of 16% at 4cm and 5cm, and 35% for 6 cm compared with the dose needed with the Mo/Mo combination.
引用
收藏
页码:716 / 723
页数:8
相关论文
共 50 条
  • [11] Imaging performance of an amorphous selenium digital mammography detector in a breast tomosynthesis system
    Zhao, Bo
    Zhao, Wei
    MEDICAL PHYSICS, 2008, 35 (05) : 1978 - 1987
  • [12] Optimizing the target-filter combination in digital mammography in the sense of image quality and average glandular dose
    Varjonen, Mari
    Strommer, Pekka
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 570 - 576
  • [13] Optimization of Image Quality in Digital Mammography with the Response of a Selenium Detector by Monte Carlo Simulation
    Szewczuk, Marek
    Konefal, Adam
    APPLIED SCIENCES-BASEL, 2023, 13 (01):
  • [14] Image Quality and Radiation Dose Assessment of a Digital Mammography System
    Isa, N. M.
    Hassan, W. M. S. W.
    Abdullah, W. A. K. W.
    Othman, F.
    Ramli, A. A. M.
    PROGRESS OF PHYSICS RESEARCH IN MALAYSIA, PERFIK2009, 2010, 1250 : 397 - +
  • [15] INFLUENCE OF ANODE AND FILTER MATERIAL ON IMAGE QUALITY AND GLANDULAR DOSE FOR SCREEN FILM MAMMOGRAPHY
    DESPONDS, L
    DEPEURSINGE, C
    GRECESCU, M
    HESSLER, C
    SAMIRI, A
    VALLEY, JF
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (09): : 1165 - 1182
  • [16] Performance of the New Double Layer Amorphous Selenium Detector for Digital Mammography Compared to the FDA Approved CR System for Digital Mammography
    Salvador, Rafael
    Salvador-Izquierdo, Rafael
    Romero, Leonardo
    Salvador-Izquierdo, Xavier
    Salvador, Manuel
    DIGITAL MAMMOGRAPHY, 2010, 6136 : 659 - 663
  • [17] Optimization of Image Quality and Dose in Digital Mammography
    Fausto, Agnes M. F.
    Lopes, M. C.
    de Sousa, M. C.
    Furquim, Tania A. C.
    Mol, Anderson W.
    Velasco, Fermin G.
    JOURNAL OF DIGITAL IMAGING, 2017, 30 (02) : 185 - 196
  • [18] Optimization of Image Quality and Dose in Digital Mammography
    Agnes M. F. Fausto
    M. C. Lopes
    M. C. de Sousa
    Tânia A. C. Furquim
    Anderson W. Mol
    Fermin G. Velasco
    Journal of Digital Imaging, 2017, 30 : 185 - 196
  • [19] A case study into the effect of radiographic factors on image quality and dose for a selenium based digital chest radiography system
    Launders, JH
    Cowen, AR
    Bury, RF
    Hawkridge, P
    RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 279 - 282
  • [20] An Evaluation of Image Quality and Dose for a Hologic Selenia Digital Mammography System with a Tungsten Anode X-Ray Tube
    Schueler, B.
    Fetterly, K.
    MEDICAL PHYSICS, 2008, 35 (06) : 2672 - +