Effect of anode/filter combination on the dose and image quality of a digital mammography system based on an amorphous selenium detector

被引:0
|
作者
Baldelli, Paola [1 ]
Phelan, Niall [1 ]
Egan, Gillian [1 ]
机构
[1] Breastcheck, Dublin, Ireland
来源
关键词
digital mammography; image quality; contrast-to-noise ratio;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
A comparison of image quality and glandular breast dose was carried out on two digital mammography systems using alpha-Se flat panel detectors. The two digital mammography systems currently available from Hologic were compared. The original system utilises Mo /Mo and Mo/Rh as target/filter combinations, while the new system uses W/Rh and W/Ag. Images of mammography phantoms with different simulated breast thickness and various glandular compositions, was calculated and the AGD needed to visualize a detail with a CNR of 5 was estimated. For each phantom thickness and target/filter combination, there is an optimum voltage which maximizes the AGD. Using the Tungsten tube system there is a dose redcution of 16% at 4cm and 5cm, and 35% for 6 cm compared with the dose needed with the Mo/Mo combination.
引用
收藏
页码:716 / 723
页数:8
相关论文
共 50 条
  • [21] Influence of anode-filter combinations on image quality and radiation dose in 965 women undergoing mammography
    ThilanderKlang, AC
    Ackerholm, PHR
    Berlin, IC
    Bjurstam, NG
    Mattsson, SLJ
    Mansson, LG
    vonScheele, C
    Thunberg, ST
    RADIOLOGY, 1997, 203 (02) : 348 - 354
  • [22] Evaluation based on breast tomosynthesis of amorphous selenium full field digital mammography system
    Varjonen, M
    Strommer, P
    MEDICAL PHYSICS, 2005, 32 (06) : 1897 - 1897
  • [23] Image quality of a photon-counting mammography system compared to digital mammography based on amorphous silicon with CsI-scintillator
    Fischmann, Arne
    Steidle, Guenther
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2006, 4046 : 441 - 446
  • [24] Experimental investigation of the dose and image quality characteristics of a digital mammography imaging system
    Huda, W
    Sajewicz, AM
    Ogden, KM
    MEDICAL PHYSICS, 2003, 30 (03) : 442 - 448
  • [25] Image quality of a prototype direct conversion detector for digital mammography
    Mainprize, JG
    Ford, NL
    Yin, S
    Tümer, T
    Yaffe, MJ
    MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 1999, 3659 : 398 - 406
  • [26] Comparison of Anode/Filter Combinations in Digital Mammography with Respect to the Average Glandular Dose
    Uhlenbrock, D. F.
    Mertelmeier, T.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (03): : 249 - 254
  • [27] Dose and image quality in mammography with an automatic beam quality system
    Young, KC
    Ramsdale, ML
    Rust, A
    BRITISH JOURNAL OF RADIOLOGY, 1996, 69 (822): : 555 - 562
  • [28] Effect of using tungsten-anode X-ray tubes on dose and image quality in full-field digital mammography
    Oduko, Jennifer M.
    Young, Kenneth C.
    Gundogdu, Ozcan
    Alsager, Abdulaziz
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 522 - +
  • [29] Effect of image quality on calcification detection in digital mammography
    Warren, Lucy M.
    Mackenzie, Alistair
    Cooke, Julie
    Given-Wilson, Rosalind M.
    Wallis, Matthew G.
    Chakraborty, Dev P.
    Dance, David R.
    Bosmans, Hilde
    Young, Kenneth C.
    MEDICAL PHYSICS, 2012, 39 (06) : 3202 - 3213
  • [30] System Comparison of Dose and Image Quality Trade-off for Thicker Breast in Digital Mammography
    Yang, Chang-Ying Joseph
    MEDICAL PHYSICS, 2019, 46 (11) : 5384 - 5384