Influence of anode-filter combinations on image quality and radiation dose in 965 women undergoing mammography

被引:39
|
作者
ThilanderKlang, AC
Ackerholm, PHR
Berlin, IC
Bjurstam, NG
Mattsson, SLJ
Mansson, LG
vonScheele, C
Thunberg, ST
机构
[1] SAHLGRENS UNIV HOSP,DEPT DIAGNOST RADIOL,S-41345 GOTHENBURG,SWEDEN
[2] MALMO UNIV HOSP,DEPT RADIAT PHYS,MALMO,SWEDEN
[3] SIEMENS ELEMA,SOLNA,SWEDEN
关键词
breast radiography; quality assurance; radiation dose; images; quality;
D O I
10.1148/radiology.203.2.9114087
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To evaluate how anode-filter combinations influence image quality in and mean glandular dose to breasts of different thicknesses and compositions. MATERIALS AND METHODS: Mammograms were obtained with a molybdenum (Mo) anode and a Mo filter at 26 kVp, a Mo anode and a rhodium (Rh) filter at 27 kVp, or a tungsten (W) anode and a Rh filter at 26 kVp in 965 women. One anode-filter-tube voltage combination was used in the right breast and another in the left. The mean glandular dose to each breast was calculated. RESULTS: Image contrast was highest in the Mo-Mo mammograms. However, depiction of the glandular tissue, pectoral muscle, and skin and subcutis was significantly (P < .001) better with the Mo-Rh and the W-Rh than with the Mo-Mo combination. The average mean absorbed doses to the glandular tissue for W-Rh and Mo-Rh were 50% and 75%, respectively, of that for Mo-Mo. CONCLUSION: Breast thickness is the most important parameter in selection of an anode-filter-tube voltage combination. Compared with Mo-Mo, both Mo-Rh and W-Rh gave good image quality of the mammary gland and a considerably lower absorbed dose. Mo-Rh-27 kVp is recommended for breast thicknesses of 60 mm or less; W-Rh-26 kVp, for breast thicknesses of greater than 60 mm.
引用
收藏
页码:348 / 354
页数:7
相关论文
共 50 条
  • [1] Optimizing the anode-filter combination in the sense of image quality and average glandular dose in digital mammography
    Varjonen, Mari
    Stroemmer, Pekka
    [J]. MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [2] Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code
    Gholamkar, Lida
    Mowlavi, Ali Asghar
    Sadeghi, Mahdi
    Athari, Mitra
    [J]. IRANIAN JOURNAL OF RADIOLOGY, 2016, 13 (04)
  • [3] INFLUENCE OF ANODE AND FILTER MATERIAL ON IMAGE QUALITY AND GLANDULAR DOSE FOR SCREEN FILM MAMMOGRAPHY
    DESPONDS, L
    DEPEURSINGE, C
    GRECESCU, M
    HESSLER, C
    SAMIRI, A
    VALLEY, JF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (09): : 1165 - 1182
  • [4] Image Quality and Radiation Dose for Fibrofatty Breast using Target/filter Combinations in Two Digital Mammography Systems
    Alkhalifah, Khaled
    Asbeutah, Akram
    Brindhaban, Ajit
    [J]. JOURNAL OF CLINICAL IMAGING SCIENCE, 2020, 10
  • [5] INFLUENCE OF ANODE/FILTER MATERIAL AND TUBE VOLTAGE ON IMAGE QUALITY AND AVERAGE GLANDULAR BREAST DOSE FOR 1,000 WOMEN AT MAMMOGRAPHY
    THILANDERKLANG, AC
    ACKERHOLM, P
    BERLIN, I
    BJURSTAM, N
    MATTSSON, S
    MANSSON, LG
    [J]. RADIOLOGY, 1995, 197 : 243 - 243
  • [6] Evaluation of dose and image quality of a mammography unit with varying target-filter combinations
    deParedes, ESS
    Fatouros, PP
    Cousins, J
    Garris, EM
    [J]. RADIOLOGY, 1996, 201 : 1516 - 1516
  • [7] Mammography radiation dose and image quality
    Jacobson, DR
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 295 - 297
  • [8] Comparison of Anode/Filter Combinations in Digital Mammography with Respect to the Average Glandular Dose
    Uhlenbrock, D. F.
    Mertelmeier, T.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (03): : 249 - 254
  • [9] MAMMOGRAPHY IN SERBIA: IMAGE QUALITY AND RADIATION DOSE
    Rafajlovic, Stefan
    Arandjic, Danijela
    Bozovic, Predrag
    Ceklic, Sandra
    Lazarevic, Djordje
    Ciraj-Bjelac, Olivera
    [J]. FOURTH INTERNATIONAL CONFERENCE ON RADIATION AND APPLICATIONS IN VARIOUS FIELDS OF RESEARCH (RAD 2016), 2016, : 29 - 32
  • [10] Calculation of the X-ray spectrum of a mammography system with various voltages and different anode-filter combinations using MCNP code
    Gholamkar, Lida
    Sadeghi, Mahdi
    Mowlavi, Ali Asghar
    Athari, Mitra
    [J]. Iranian Journal of Medical Physics, 2016, 13 (03) : 154 - 162