Optimizing the anode-filter combination in the sense of image quality and average glandular dose in digital mammography

被引:2
|
作者
Varjonen, Mari [1 ]
Stroemmer, Pekka [1 ]
机构
[1] Planmed Oy, FIN-00880 Helsinki, Finland
关键词
digital mammography (DM); average glandular dose (AGD); amorphous selenium (a-Se);
D O I
10.1117/12.768083
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents the optimized image quality and average glandular dose in digital mammography, and provides recommendations concerning anode-filter combinations in digital mammography, which is based on amorphous selenium (a-Se) detector technology. The full field digital mammography (FFDM) system based on a-Se technology, which is also a platform of tomosynthesis prototype, was used in this study. X-ray tube anode-filter combinations, which we studied, were tungsten (W) - rhodium (Rh) and tungsten (W) - silver (Ag). Anatomically adaptable fully automatic exposure control (AAEC) was used. The average glandular doses (AGD) were calculated using a specific program developed by Planmed, which automates the method described by Dance et al. Image quality was evaluated in two different ways: a subjective image quality evaluation, and contrast and noise analysis. By using W-Rh and W-Ag anode-filter combinations can be achieved a significantly lower average glandular dose compared with molybdenum (Mo) - molybdenum (Mo) or Mo-Rh. The average glandular dose reduction was achieved from 25 % to 60 %. In the future, the evaluation will concentrate to study more filter combinations and the effect of higher W (>35 W) values, which seems be useful while optimizing the dose in digital mammography.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Optimizing the target-filter combination in digital mammography in the sense of image quality and average glandular dose
    Varjonen, Mari
    Strommer, Pekka
    [J]. DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 570 - 576
  • [2] Effect of filter on average glandular dose and image quality in digital mammography
    Songsaeng, C.
    Krisanachinda, A.
    Theerakul, K.
    [J]. 13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [3] Effect of anode/filter combination on average glandular dose in mammography
    Biegala, Michal
    Jakubowska, Teresa
    Markowska, Karolina
    [J]. JOURNAL OF MEDICAL PHYSICS, 2015, 40 (01) : 45 - 51
  • [4] Comparison of Anode/Filter Combinations in Digital Mammography with Respect to the Average Glandular Dose
    Uhlenbrock, D. F.
    Mertelmeier, T.
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2009, 181 (03): : 249 - 254
  • [5] Influence of anode-filter combinations on image quality and radiation dose in 965 women undergoing mammography
    ThilanderKlang, AC
    Ackerholm, PHR
    Berlin, IC
    Bjurstam, NG
    Mattsson, SLJ
    Mansson, LG
    vonScheele, C
    Thunberg, ST
    [J]. RADIOLOGY, 1997, 203 (02) : 348 - 354
  • [6] Average glandular dose and phantom image quality in mammography
    Oliveira, M.
    Noguelra, M. S.
    Guedes, E.
    Andrade, M. C.
    Peixoto, J. E.
    Joana, G. S.
    Castro, J. G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 574 - 577
  • [7] INFLUENCE OF ANODE AND FILTER MATERIAL ON IMAGE QUALITY AND GLANDULAR DOSE FOR SCREEN FILM MAMMOGRAPHY
    DESPONDS, L
    DEPEURSINGE, C
    GRECESCU, M
    HESSLER, C
    SAMIRI, A
    VALLEY, JF
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (09): : 1165 - 1182
  • [8] Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code
    Gholamkar, Lida
    Mowlavi, Ali Asghar
    Sadeghi, Mahdi
    Athari, Mitra
    [J]. IRANIAN JOURNAL OF RADIOLOGY, 2016, 13 (04)
  • [9] Optimization of image quality and average glandular dose in CR mammography
    Satoh, Kimihiko
    Kuwabara, Takao
    Yasuda, Hiroaki
    Arakawa, Satoshi
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [10] INFLUENCE OF ANODE/FILTER MATERIAL AND TUBE VOLTAGE ON IMAGE QUALITY AND AVERAGE GLANDULAR BREAST DOSE FOR 1,000 WOMEN AT MAMMOGRAPHY
    THILANDERKLANG, AC
    ACKERHOLM, P
    BERLIN, I
    BJURSTAM, N
    MATTSSON, S
    MANSSON, LG
    [J]. RADIOLOGY, 1995, 197 : 243 - 243