Effect of using tungsten-anode X-ray tubes on dose and image quality in full-field digital mammography

被引:0
|
作者
Oduko, Jennifer M. [1 ]
Young, Kenneth C. [1 ,2 ]
Gundogdu, Ozcan [1 ]
Alsager, Abdulaziz [2 ]
机构
[1] Royal Surrey Cty Hosp, Natl Coordinating Ctr Phys Mammog, Guildford GU2 7XX, Surrey, England
[2] Univ Surrey, Dept Phys, Guildford GU2 5XH, Surrey, England
来源
关键词
dose; image quality; digital mammography; FFDM; tungsten;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Dose and image quality have been evaluated for two types of digital mammography system which have X-ray tubes with tungsten anodes, the Siemens Novation and the Hologic Selenia. For each system, contrast-to-noise ratio and threshold contrast measurements were made. The results were used to determine the optimum exposure settings for each system to meet the achievable image quality standard of the European Guidelines. For the Selenia systems, dose savings between 9% and 52% were achieved by using a tungsten-target tube, for PMMA thickness ranging from 20 to 70mm. For the Novation, for the same range of PMMA thickness simulating breasts, the dose saving was 10% to 50% when using a W/Rh rather than Mo/Mo target-filter combination. When comparing W/Rh with Mo/Rh for the Novation, a more modest dose reduction ranging from 4% to 18% was achieved.
引用
收藏
页码:522 / +
页数:2
相关论文
共 50 条
  • [1] Adaptive image interpolation for full-field digital x-ray mammography
    Liu, H
    Wang, G
    Xu, F
    Fajardo, LL
    [J]. APPLIED OPTICS, 1999, 38 (01) : 253 - 257
  • [2] X-ray scattering in full-field digital mammography
    Nykänen, K
    Siltanen, S
    [J]. MEDICAL PHYSICS, 2003, 30 (07) : 1864 - 1873
  • [3] An Evaluation of Image Quality and Dose for a Hologic Selenia Digital Mammography System with a Tungsten Anode X-Ray Tube
    Schueler, B.
    Fetterly, K.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2672 - +
  • [4] Effect of area x-ray beam equalization on image quality and dose in digital mammography
    Wong, J
    Xu, T
    Husain, A
    Le, H
    Molloi, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (16): : 3539 - 3557
  • [5] Effect of area x-ray beam equalization on image quality and dose in digital mammography
    Wong, J
    Xu, T
    Husain, A
    Le, H
    Molloi, S
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1712 - 1712
  • [6] X-ray spectrum optimization of full-field digital mammography: Simulation and phantom study
    Bernhardt, Philipp
    Mertelmeier, Thomas
    Hoheisel, Martin
    [J]. MEDICAL PHYSICS, 2006, 33 (11) : 4337 - 4349
  • [7] X-RAY MAMMOGRAPHY - IMAGE QUALITY AND PATIENT DOSE
    MASTERSON, ME
    [J]. MEDICAL PHYSICS, 1985, 12 (04) : 555 - 555
  • [8] Monoenergetic X-ray beam in digital full field mammography
    Diekmann, F
    Diekmann, SD
    Fischer, T
    Arkadiev, V
    Lawaczeck, R
    Hamm, BK
    [J]. RADIOLOGY, 2002, 225 : 417 - 417
  • [9] The first trial of phase contrast imaging for digital full-field mammography using a practical molybdenum X-ray tube
    Tanaka, T
    Honda, C
    Matsuo, S
    Noma, K
    Oohara, H
    Nitta, N
    Ota, S
    Tsuchiya, K
    Sakashita, Y
    Yamada, A
    Yamasaki, M
    Furukawa, A
    Takahashi, M
    Murata, K
    [J]. INVESTIGATIVE RADIOLOGY, 2005, 40 (07) : 385 - 396
  • [10] Experimental evaluation of the image quality and dose in digital mammography: Influence of x-ray spectrum
    Tomal, A.
    Perez, A. M. M. M.
    Silva, M. C.
    Poletti, M. E.
    [J]. RADIATION PHYSICS AND CHEMISTRY, 2015, 116 : 282 - 286