Effect of using tungsten-anode X-ray tubes on dose and image quality in full-field digital mammography

被引:0
|
作者
Oduko, Jennifer M. [1 ]
Young, Kenneth C. [1 ,2 ]
Gundogdu, Ozcan [1 ]
Alsager, Abdulaziz [2 ]
机构
[1] Royal Surrey Cty Hosp, Natl Coordinating Ctr Phys Mammog, Guildford GU2 7XX, Surrey, England
[2] Univ Surrey, Dept Phys, Guildford GU2 5XH, Surrey, England
来源
关键词
dose; image quality; digital mammography; FFDM; tungsten;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Dose and image quality have been evaluated for two types of digital mammography system which have X-ray tubes with tungsten anodes, the Siemens Novation and the Hologic Selenia. For each system, contrast-to-noise ratio and threshold contrast measurements were made. The results were used to determine the optimum exposure settings for each system to meet the achievable image quality standard of the European Guidelines. For the Selenia systems, dose savings between 9% and 52% were achieved by using a tungsten-target tube, for PMMA thickness ranging from 20 to 70mm. For the Novation, for the same range of PMMA thickness simulating breasts, the dose saving was 10% to 50% when using a W/Rh rather than Mo/Mo target-filter combination. When comparing W/Rh with Mo/Rh for the Novation, a more modest dose reduction ranging from 4% to 18% was achieved.
引用
收藏
页码:522 / +
页数:2
相关论文
共 50 条
  • [21] Development of a quality control system for full-field digital mammography
    Yaffe, MJ
    Williams, MB
    Niklason, LT
    Mawdsley, GE
    Maidment, AD
    RADIOLOGY, 1998, 209P : 160 - 160
  • [22] SCREEN-FILM VERSUS FULL-FIELD DIGITAL MAMMOGRAPHY: RADIATION DOSE AND IMAGE QUALITY IN A LARGE TEACHING HOSPITAL
    Stantic, Tomislav J.
    Ciraj-Bjelac, Olivera E.
    Stojanovic, Saida S.
    Basta-Nikolic, Marijana D.
    Arandjic, Danijela D.
    Stoiljkovic, Dragana S.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2013, 28 (04): : 398 - 405
  • [23] Determination of dose delivery accuracy and image quality in full - Field digital mammography
    Sosu, E. K.
    Boadu, M.
    Mensah, S. Y.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2018, 11 (03) : 232 - 236
  • [24] X-ray spectral measurements for tungsten-anode from 20 to 49 kVp on a digital breast tomosynthesis system
    Zhang, Da
    Li, Xinhua
    Liu, Bob
    MEDICAL PHYSICS, 2012, 39 (06) : 3493 - 3500
  • [25] Dose comparison between screen/film and full-field digital mammography
    Gennaro, Gisella
    di Maggio, Cosimo
    EUROPEAN RADIOLOGY, 2006, 16 (11) : 2559 - 2566
  • [26] Evaluation of the exposure dose reduction in full-field digital mammography system
    Tanigoshi, M
    Kobayashi, H
    Uchiyama, N
    Suzuki, T
    Kumazaki, T
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 149 - 151
  • [27] Dose reduction through gridless technique in digital full-field mammography
    Diekmann, F
    Diekmann, S
    Berzeg, S
    Bick, U
    Fischer, T
    Hamm, B
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2003, 175 (06): : 769 - 774
  • [28] Indices for the evaluation of glandular dose heterogeneity in full-field digital mammography
    Shinohara, Sae
    Araki, Fujio
    Maeda, Megumi
    Okamoto, Rumi
    Nakamura, Mai
    Higashida, Yoshiharu
    JOURNAL OF RADIOLOGICAL PROTECTION, 2020, 40 (04) : 1429 - 1443
  • [29] Average glandular dose with full-field digital mammography - Clinical results
    Hermann, KP
    Kehbel, S
    Obenauer, S
    Fischer, U
    Grabbe, E
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2003, : 502 - 504
  • [30] Grid removal and impact on population dose in full-field digital mammography
    Gennaro, Gisella
    Katz, Luc
    Souchay, Henri
    Klausz, Remy
    Alberelli, Claudio
    di Maggio, Cosimo
    MEDICAL PHYSICS, 2007, 34 (02) : 547 - 555