Optimization of Image Quality and Dose in Digital Mammography

被引:0
|
作者
Agnes M. F. Fausto
M. C. Lopes
M. C. de Sousa
Tânia A. C. Furquim
Anderson W. Mol
Fermin G. Velasco
机构
[1] Universidade Estadual de Santa Cruz,Departamento de Ciências Exatas e Tecnológicas—DCET/CPqCTR
[2] IPOCFG,Departamento de Física, I3N
[3] E.P.E.,Instituto de Física, Laboratório de Dosimetria
[4] Serviço de Física Médica,undefined
[5] Universidade de Aveiro,undefined
[6] Universidade de São Paulo—USP,undefined
来源
关键词
Digital mammography; Image quality; Contrast-detail analysis; Figure of merit; Optimization; CDMAM; TORMAM;
D O I
暂无
中图分类号
学科分类号
摘要
Nowadays, the optimization in digital mammography is one of the most important challenges in diagnostic radiology. The new digital technology has introduced additional elements to be considered in this scenario. A major goal of mammography is related to the detection of structures on the order of micrometers (μm) and the need to distinguish the different types of tissues, with very close density values. The diagnosis in mammography faces the difficulty that the breast tissues and pathological findings have very close linear attenuation coefficients within the energy range used in mammography. The aim of this study was to develop a methodology for optimizing exposure parameters of digital mammography based on a new Figure of Merit: FOM ≡ (IQFinv)2/AGD, considering the image quality and dose. The study was conducted using the digital mammography Senographe DS/GE, and CDMAM and TORMAM phantoms. The characterization of clinical practice, carried out in the mammography system under study, was performed considering different breast thicknesses, the technical parameters of exposure, and processing options of images used by the equipment’s automatic exposure system. The results showed a difference between the values of the optimized parameters and those ones chosen by the automatic system of the mammography unit, specifically for small breast. The optimized exposure parameters showed better results than those obtained by the automatic system of the mammography, for the image quality parameters and its impact on detection of breast structures when analyzed by radiologists.
引用
收藏
页码:185 / 196
页数:11
相关论文
共 50 条
  • [1] Optimization of Image Quality and Dose in Digital Mammography
    Fausto, Agnes M. F.
    Lopes, M. C.
    de Sousa, M. C.
    Furquim, Tania A. C.
    Mol, Anderson W.
    Velasco, Fermin G.
    [J]. JOURNAL OF DIGITAL IMAGING, 2017, 30 (02) : 185 - 196
  • [2] Image Quality and Radiation Dose Assessment of a Digital Mammography System
    Isa, N. M.
    Hassan, W. M. S. W.
    Abdullah, W. A. K. W.
    Othman, F.
    Ramli, A. A. M.
    [J]. PROGRESS OF PHYSICS RESEARCH IN MALAYSIA, PERFIK2009, 2010, 1250 : 397 - +
  • [3] Optimization of image quality and average glandular dose in CR mammography
    Satoh, Kimihiko
    Kuwabara, Takao
    Yasuda, Hiroaki
    Arakawa, Satoshi
    [J]. MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [4] Historical trends in image quality and mean glandular dose in digital mammography
    Mackenzie, Alistair
    Khan, Riyad
    Young, Kenneth C.
    [J]. 15TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI2020), 2020, 11513
  • [5] Dose sensitivity of three methods of image quality assessment in digital mammography
    Hummel, Johann
    Kaar, Marcus
    Hoffmann, Rainer
    Kaldarar, Heinrich
    Semturs, Friedrich
    Homolka, Peter
    Figl, Michael
    [J]. MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [6] Effect of filter on average glandular dose and image quality in digital mammography
    Songsaeng, C.
    Krisanachinda, A.
    Theerakul, K.
    [J]. 13TH SOUTH-EAST ASIAN CONGRESS OF MEDICAL PHYSICS 2015 (SEACOMP), 2016, 694
  • [7] OPTIMIZATION OF IMAGE QUALITY IN MAMMOGRAPHY
    ROBSON, KJ
    KOTRE, CJ
    FAULKNER, K
    [J]. RADIATION PROTECTION DOSIMETRY, 1995, 57 (1-4) : 151 - 154
  • [8] Decreased patient dose and improved image quality in digital mammography with Bayesian image estimation
    Baydush, AH
    Floyd, CE
    [J]. RADIOLOGY, 2000, 217 : 347 - 347
  • [9] Optimizing mammography image quality and dose
    Berns, E.
    [J]. MEDICAL PHYSICS, 2006, 33 (06) : 2260 - 2260
  • [10] Mammography radiation dose and image quality
    Jacobson, DR
    [J]. RADIATION PROTECTION DOSIMETRY, 1998, 80 (1-3) : 295 - 297