Optimization of Image Quality and Dose in Digital Mammography

被引:0
|
作者
Agnes M. F. Fausto
M. C. Lopes
M. C. de Sousa
Tânia A. C. Furquim
Anderson W. Mol
Fermin G. Velasco
机构
[1] Universidade Estadual de Santa Cruz,Departamento de Ciências Exatas e Tecnológicas—DCET/CPqCTR
[2] IPOCFG,Departamento de Física, I3N
[3] E.P.E.,Instituto de Física, Laboratório de Dosimetria
[4] Serviço de Física Médica,undefined
[5] Universidade de Aveiro,undefined
[6] Universidade de São Paulo—USP,undefined
来源
关键词
Digital mammography; Image quality; Contrast-detail analysis; Figure of merit; Optimization; CDMAM; TORMAM;
D O I
暂无
中图分类号
学科分类号
摘要
Nowadays, the optimization in digital mammography is one of the most important challenges in diagnostic radiology. The new digital technology has introduced additional elements to be considered in this scenario. A major goal of mammography is related to the detection of structures on the order of micrometers (μm) and the need to distinguish the different types of tissues, with very close density values. The diagnosis in mammography faces the difficulty that the breast tissues and pathological findings have very close linear attenuation coefficients within the energy range used in mammography. The aim of this study was to develop a methodology for optimizing exposure parameters of digital mammography based on a new Figure of Merit: FOM ≡ (IQFinv)2/AGD, considering the image quality and dose. The study was conducted using the digital mammography Senographe DS/GE, and CDMAM and TORMAM phantoms. The characterization of clinical practice, carried out in the mammography system under study, was performed considering different breast thicknesses, the technical parameters of exposure, and processing options of images used by the equipment’s automatic exposure system. The results showed a difference between the values of the optimized parameters and those ones chosen by the automatic system of the mammography unit, specifically for small breast. The optimized exposure parameters showed better results than those obtained by the automatic system of the mammography, for the image quality parameters and its impact on detection of breast structures when analyzed by radiologists.
引用
收藏
页码:185 / 196
页数:11
相关论文
共 50 条
  • [31] Effect of area x-ray beam equalization on image quality and dose in digital mammography
    Wong, J
    Xu, T
    Husain, A
    Le, H
    Molloi, S
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (16): : 3539 - 3557
  • [32] System Comparison of Dose and Image Quality Trade-off for Thicker Breast in Digital Mammography
    Yang, Chang-Ying Joseph
    [J]. MEDICAL PHYSICS, 2019, 46 (11) : 5384 - 5384
  • [33] SIMULTANEOUS OBJECTIVE MEASUREMENTS OF DOSE AND IMAGE QUALITY IN MAMMOGRAPHY
    POCHON, Y
    DEPEURSINGE, CH
    HESSLER, C
    RAIMONDI, S
    VALLEY, JF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (02) : 429 - 429
  • [34] IMAGE QUALITY FACTORS AND RADIATION-DOSE IN MAMMOGRAPHY
    HAUS, AG
    ERICKSON, L
    [J]. JOURNAL OF IMAGING TECHNOLOGY, 1984, 10 (01): : 29 - 35
  • [35] STANDARDIZATION OF IMAGE QUALITY AND RADIATION-DOSE IN MAMMOGRAPHY
    HENDRICK, RE
    [J]. RADIOLOGY, 1990, 174 (03) : 648 - 654
  • [36] IMAGE QUALITY FACTORS AND RADIATION DOSE IN MAMMOGRAPHY.
    Haus, Arthur G.
    Erickson, Leland
    [J]. 1600, (10):
  • [37] Average glandular dose and phantom image quality in mammography
    Oliveira, M.
    Noguelra, M. S.
    Guedes, E.
    Andrade, M. C.
    Peixoto, J. E.
    Joana, G. S.
    Castro, J. G.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 574 - 577
  • [38] DETERMINATION OF IMAGE QUALITY IN RELATION TO ABSORBED DOSE IN MAMMOGRAPHY
    ZOETELIEF, J
    JANSEN, JTM
    DEWIT, NJP
    [J]. RADIATION PROTECTION DOSIMETRY, 1993, 49 (1-3) : 157 - 161
  • [39] SIMULTANEOUS OBJECTIVE MEASUREMENTS OF DOSE AND IMAGE QUALITY IN MAMMOGRAPHY
    POCHON, Y
    DEPEURSINGE, C
    HESSLER, C
    RAIMONDI, S
    VALLEY, JF
    [J]. PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1982, 347 : 238 - 245
  • [40] Influence of the Acquisition Parameters on the Image Quality in Digital Mammography
    Al Kattar, Zeina
    El Balaa, Hanna
    Harb, Huda
    Raad, Nisrine
    Hodroj, Noor
    Sleiman, Fatina
    Omayrat, Samia
    [J]. 2015 INTERNATIONAL CONFERENCE ON ADVANCES IN BIOMEDICAL ENGINEERING (ICABME), 2015, : 33 - 36