Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE

被引:6
|
作者
Almansa, Julio F. [1 ]
Guerrero, Rafael [1 ]
Torres, Javier [2 ]
Lallena, Antonio M. [3 ]
机构
[1] Complejo Hosp Univ Granada, Serv Fis & Protecc Radiol, Granada, Spain
[2] Hosp Gen Univ Ciudad Real, Serv Radiofis & Protecc Radiol, Ciudad Real, Spain
[3] Univ Granada, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain
关键词
Monte Carlo dosimetry; Brachytherapy; (CO)-C-60; HDR; PENELOPE; TECHNICAL NOTE; AAPM; PARAMETERS;
D O I
10.1016/j.brachy.2017.04.245
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Co-60 sources have been commercialized as an alternative to Ir-192 sources for high dose-rate (HDR) brachytherapy. One of them is the Flexisource Co-60 HDR source manufactured by Elekta. The only available dosimetric characterization of this source is that of Vijande et al. [J Contemp Brachytherapy 2012; 4:34-44], whose results were not included in the AAPM/ESTRO consensus document. In that work, the dosimetric quantities were calculated as averages of the results obtained with the Geant4 and PENELOPE Monte Carlo (MC) codes, though for other sources, significant differences have been quoted between the values obtained with these two codes. The aim of this work is to perform the dosimetric characterization of the Flexisource Co-60 HDR source using PENELOPE. METHODS AND MATERIALS: The MC simulation code PENELOPE (v. 2014) has been used. Following the recommendations of the AAPM/ESTRO report, the radial dose function, the anisotropy function, the air-kerma strength, the dose rate constant, and the absorbed dose rate in water have been calculated. RESULTS: The results we have obtained exceed those of Vijande et al. In particular, the absorbed dose rate constant is similar to 0.85% larger. A similar difference is also found in the other dosimetric quantities. The effect of the electrons emitted in the decay of Co-60, usually neglected in this kind of simulations, is significant up to the distances of 0.25 cm from the source. CONCLUSIONS: The systematic and significant differences we have found between PENELOPE results and the average values found by Vijande et al. point out that the dosimetric characterizations carried out with the various MC codes should be provided independently. (C) 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1073 / 1080
页数:8
相关论文
共 50 条
  • [1] Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source
    Vijande, Javier
    Granero, Domingo
    Perez-Calatayud, Jose
    Ballester, Facundo
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2012, 4 (01) : 34 - 44
  • [2] Monte Carlo Dosimetric Study of the New Flexisource Co-60 High Dose Rate Source
    Vijande, J.
    Granero, D.
    Perez-Calatayud, J.
    Ballester, F.
    MEDICAL PHYSICS, 2012, 39 (06) : 3812 - 3812
  • [3] Dosimetric characterization of the 60Co BEBIG Co0.A86 high dose rate brachytherapy source using PENELOPE
    Guerrero, Rafael
    Almansa, Julio F.
    Torres, Javier
    Lallena, Antonio M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (08): : 960 - 967
  • [4] Characterization of a high-dose-rate 90Sr-90Y source for intravascular brachytherapy by using the Monte Carlo code PENELOPE
    Asenjo, J
    Fernández-Varea, JM
    Sánchez-Reyes, A
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (05): : 697 - 711
  • [5] An analytic approach to the dosimetry of a new BEBIG Co-60 high-dose-rate brachytherapy source
    Bhola, Subhalaxmi
    Selvam, T. Palani
    Sridhar, Sahoo
    Vishwakarma, Ramkrishna S.
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (03) : 129 - 137
  • [6] Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
    Campos, L. T.
    de Almeida, C. E. V.
    MEDICAL PHYSICS, 2016, 43 (06) : 3464 - 3464
  • [7] Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE
    Javier Casado, Francisco
    Garcia-Pareja, Salvador
    Cenizo, Elena
    Mateo, Beatriz
    Bodineau, Coral
    Galan, Pedro
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2010, 26 (03): : 132 - 139
  • [8] Monte Carlo characterization of 169Yb as a high-dose-rate source for brachytherapy application by FLUKA code
    Anjomrouz, Marzieh
    Sadeghi, Mahdi
    Haddadi, Asghar
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (04): : 196 - 205
  • [9] Measurements and Monte Carlo calculation of radial dose and anisotropy functions of BEBIG 60Co high-dose-rate brachytherapy source in a bounded water phantom
    Reddy, Buchapudi Rekha
    Chamberland, Marc J. P.
    Ravikumar, Manickam
    Varatharaj, Chandraraj
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (06) : 563 - 572
  • [10] Dosimetric Evaluation of Treatment Planing System on High-Dose-Rate (HDR) Brachytherapy Using Monte Carlo Method and Radiochomic Film
    Pavan, G.
    Martins, M.
    Salmon, H.
    Anderson, E.
    Nardi, S.
    Fairbanks, L.
    Silva, D.
    Cursino, F.
    Junior, J.
    Silva, A.
    Santos, D.
    Werner, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S743 - S743