Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE

被引:6
|
作者
Almansa, Julio F. [1 ]
Guerrero, Rafael [1 ]
Torres, Javier [2 ]
Lallena, Antonio M. [3 ]
机构
[1] Complejo Hosp Univ Granada, Serv Fis & Protecc Radiol, Granada, Spain
[2] Hosp Gen Univ Ciudad Real, Serv Radiofis & Protecc Radiol, Ciudad Real, Spain
[3] Univ Granada, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain
关键词
Monte Carlo dosimetry; Brachytherapy; (CO)-C-60; HDR; PENELOPE; TECHNICAL NOTE; AAPM; PARAMETERS;
D O I
10.1016/j.brachy.2017.04.245
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Co-60 sources have been commercialized as an alternative to Ir-192 sources for high dose-rate (HDR) brachytherapy. One of them is the Flexisource Co-60 HDR source manufactured by Elekta. The only available dosimetric characterization of this source is that of Vijande et al. [J Contemp Brachytherapy 2012; 4:34-44], whose results were not included in the AAPM/ESTRO consensus document. In that work, the dosimetric quantities were calculated as averages of the results obtained with the Geant4 and PENELOPE Monte Carlo (MC) codes, though for other sources, significant differences have been quoted between the values obtained with these two codes. The aim of this work is to perform the dosimetric characterization of the Flexisource Co-60 HDR source using PENELOPE. METHODS AND MATERIALS: The MC simulation code PENELOPE (v. 2014) has been used. Following the recommendations of the AAPM/ESTRO report, the radial dose function, the anisotropy function, the air-kerma strength, the dose rate constant, and the absorbed dose rate in water have been calculated. RESULTS: The results we have obtained exceed those of Vijande et al. In particular, the absorbed dose rate constant is similar to 0.85% larger. A similar difference is also found in the other dosimetric quantities. The effect of the electrons emitted in the decay of Co-60, usually neglected in this kind of simulations, is significant up to the distances of 0.25 cm from the source. CONCLUSIONS: The systematic and significant differences we have found between PENELOPE results and the average values found by Vijande et al. point out that the dosimetric characterizations carried out with the various MC codes should be provided independently. (C) 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1073 / 1080
页数:8
相关论文
共 50 条
  • [31] Monte Carlo characterization of a new Yb-169 high dose rate source for brachytherapy application
    Cazeca, Mario J.
    Medich, David C.
    Munro, John J., III
    MEDICAL PHYSICS, 2010, 37 (03) : 1129 - 1136
  • [32] Dosimetric comparison between microSelectron iridium-192 and flexi cobalt-60 sources in high-dose-rate brachytherapy using Geant4 Monte Carlo code
    Gebremariam, Tsige Yhidego
    Geraily, Ghazale
    Jassim, Hussam Hameed
    Gholami, Somayeh
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2023, 15 (02) : 141 - 147
  • [33] Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism
    Minh-Tri Ho Thanh
    Munro, John J., III
    Medich, David C.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (03): : 305 - 317
  • [34] Monte Carlo Dosimetric Study of the GZP 60Co Brachytherapy Source with Stainless Steel Applicator
    Wu, J.
    Wang, P.
    Wang, X.
    Kang, S.
    Li, J.
    Tang, B.
    Orlandini, L. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E564 - E564
  • [35] Quality Assurance Tool for Determination of Position and Transit Time of a Co-60 Source in High Dose Rate Brachytherapy
    Piriz, G.
    Ortega, H.
    Gonzalez-Sprinberg, G.
    MEDICAL PHYSICS, 2020, 47 (06) : E836 - E836
  • [36] Quality assurance tool for determination of position and transit time of a Co-60 source in high dose rate brachytherapy
    Piriz, Gustavo H.
    Ortega-Spina, Henry G.
    Gonzalez-Sprinberg, Gabriel A.
    APPLIED RADIATION AND ISOTOPES, 2021, 178
  • [37] A dosimetric comparison of MammoSite high-dose-rate brachytherapy and Xoft Axxent electronic brachytherapy
    Dickler, Adam
    Kirk, Michael C.
    Seif, Neil
    Griem, Katherine
    Dowlatshahi, Kambiz
    Francescatti, Darius
    Abrams, Ross A.
    BRACHYTHERAPY, 2007, 6 (02) : 164 - 168
  • [38] THUBrachy: fast Monte Carlo dose calculation tool accelerated by heterogeneous hardware for high-dose-rate brachytherapy
    Hu, An-Kang
    Qiu, Rui
    Liu, Huan
    Wu, Zhen
    Li, Chun-Yan
    Zhang, Hui
    Li, Jun-Li
    Yang, Rui-Jie
    NUCLEAR SCIENCE AND TECHNIQUES, 2021, 32 (03)
  • [39] THUBrachy: fast Monte Carlo dose calculation tool accelerated by heterogeneous hardware for high-dose-rate brachytherapy
    An-Kang Hu
    Rui Qiu
    Huan Liu
    Zhen Wu
    Chun-Yan Li
    Hui Zhang
    Jun-Li Li
    Rui-Jie Yang
    Nuclear Science and Techniques, 2021, 32 (03) : 109 - 121
  • [40] THUBrachy: fast Monte Carlo dose calculation tool accelerated by heterogeneous hardware for high-dose-rate brachytherapy
    An-Kang Hu
    Rui Qiu
    Huan Liu
    Zhen Wu
    Chun-Yan Li
    Hui Zhang
    Jun-Li Li
    Rui-Jie Yang
    Nuclear Science and Techniques, 2021, 32