Quality assurance tool for determination of position and transit time of a Co-60 source in high dose rate brachytherapy

被引:0
|
作者
Piriz, Gustavo H. [1 ]
Ortega-Spina, Henry G. [1 ]
Gonzalez-Sprinberg, Gabriel A. [1 ]
机构
[1] Univ Republica, Fac Ciencias, Montevideo 11400, Uruguay
关键词
Brachytherapy; Cobalt-60; Quality assurance; hdr; IR-192; BRACHYTHERAPY;
D O I
10.1016/j.apradiso.2021.109971
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, three holders were designed, constructed and characterized to perform quality assurance on the source position and transit time in remote afterloading systems with Co-60 sources for high dose rate brachytherapy. The holders design focused on achieving accuracy, low cost, and a time efficient tool for use in clinical settings. Sensitivities greater than 0.6%/mm and maximum precisions better than 0.14 mm for the source position were obtained. The transit time was determined for the holders with a relative precision better than 19%.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Quality Assurance Tool for Determination of Position and Transit Time of a Co-60 Source in High Dose Rate Brachytherapy
    Piriz, G.
    Ortega, H.
    Gonzalez-Sprinberg, G.
    MEDICAL PHYSICS, 2020, 47 (06) : E836 - E836
  • [2] A quality assurance tool for high-dose-rate brachytherapy
    Rickey, Daniel W.
    Sasaki, David
    Bews, Jeff
    MEDICAL PHYSICS, 2010, 37 (06) : 2525 - 2532
  • [3] QUALITY ASSURANCE TOOL FOR HIGH-DOSE-RATE BRACHYTHERAPY
    DEWERD, LA
    JURSINIC, P
    KITCHEN, R
    THOMADSEN, BR
    MEDICAL PHYSICS, 1995, 22 (04) : 435 - 440
  • [4] High dose-rate brachytherapy source position quality assurance using radiochromic film
    Evans, M. D. C.
    Devic, S.
    Podgorsak, E. B.
    MEDICAL DOSIMETRY, 2007, 32 (01) : 13 - 15
  • [5] A Study of Computed Radiography for High Dose-Rate Brachytherapy Source Position Quality Assurance
    Piriyasang, D.
    Tangboonduangjit, P.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [6] An analytic approach to the dosimetry of a new BEBIG Co-60 high-dose-rate brachytherapy source
    Bhola, Subhalaxmi
    Selvam, T. Palani
    Sridhar, Sahoo
    Vishwakarma, Ramkrishna S.
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (03) : 129 - 137
  • [7] Determination of Changes in Dosimetric Parameters with Co-60 and Ir-192 Source in High Dose Rate Brachytherapy of Cervical Carcinoma
    Srivastava, S.
    Moirangthem, N.
    Singh, N.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [8] Implementation of the Sievert integral for the calculation of dose distribution around the BEBIG Co-60 high dose rate brachytherapy source
    Dumenya, Castrol
    Hasford, Francis
    Tagoe, Samuel Nii Adu
    Sasu, Evans
    Pokoo-Aikins, Mark
    Asamanyuah, Belinda Buermle
    Amuasi, John Humphrey
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2022, 28 (02): : 90 - 98
  • [9] Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE
    Almansa, Julio F.
    Guerrero, Rafael
    Torres, Javier
    Lallena, Antonio M.
    BRACHYTHERAPY, 2017, 16 (05) : 1073 - 1080
  • [10] A quality assurance device for measuring afterloader performance and transit dose for nasobiliary high-dose-rate brachytherapy
    Deufel, Christopher L.
    Mullins, John P.
    Zakhary, Mark J.
    BRACHYTHERAPY, 2018, 17 (04) : 726 - 731