Quality assurance tool for determination of position and transit time of a Co-60 source in high dose rate brachytherapy

被引:0
|
作者
Piriz, Gustavo H. [1 ]
Ortega-Spina, Henry G. [1 ]
Gonzalez-Sprinberg, Gabriel A. [1 ]
机构
[1] Univ Republica, Fac Ciencias, Montevideo 11400, Uruguay
关键词
Brachytherapy; Cobalt-60; Quality assurance; hdr; IR-192; BRACHYTHERAPY;
D O I
10.1016/j.apradiso.2021.109971
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, three holders were designed, constructed and characterized to perform quality assurance on the source position and transit time in remote afterloading systems with Co-60 sources for high dose rate brachytherapy. The holders design focused on achieving accuracy, low cost, and a time efficient tool for use in clinical settings. Sensitivities greater than 0.6%/mm and maximum precisions better than 0.14 mm for the source position were obtained. The transit time was determined for the holders with a relative precision better than 19%.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Measurement of transit time of a remote after-loading high dose rate brachytherapy source
    Sahoo, N
    MEDICAL PHYSICS, 2001, 28 (08) : 1786 - 1790
  • [22] Monte Carlo Dosimetric Study of the New Flexisource Co-60 High Dose Rate Source
    Vijande, J.
    Granero, D.
    Perez-Calatayud, J.
    Ballester, F.
    MEDICAL PHYSICS, 2012, 39 (06) : 3812 - 3812
  • [23] "Magic phantom" - a quality assurance system for high dose rate brachytherapy
    Espinoza, A.
    Petasecca, M.
    Fuduli, I.
    Howie, A.
    Corde, S.
    Bucci, J.
    Jackson, M.
    Lerch, M. L. F.
    Rosenfeld, A. B.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S139 - S140
  • [24] A Quality Assurance System with a Web Camera for High Dose Rate Brachytherapy
    Ueda, Y.
    Hirose, A.
    Oohira, S.
    Isono, M.
    Tsujii, K.
    Miyazaki, M.
    Kawaguchi, Y.
    Konishi, K.
    Teshima, T.
    MEDICAL PHYSICS, 2015, 42 (06) : 3346 - 3346
  • [25] Transit dose of an Ir-192 high dose rate brachytherapy stepping source
    Wong, TPY
    Fernando, W
    Johnston, PN
    Bubb, IF
    PHYSICS IN MEDICINE AND BIOLOGY, 2001, 46 (02): : 323 - 331
  • [26] Dosimetric analysis of Co-60 source based high dose rate (HDR) brachytherapy: A case series of ten patients with carcinoma of the uterine cervix
    Gurjar, Om Prakash
    Batra, Manika
    Bagdare, Priyusha
    Kaushik, Sandeep
    Tyagi, Atul
    Naik, Ayush
    Bhandari, Virendra
    Gupta, Krishna Lal
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2016, 21 (03) : 201 - 206
  • [27] Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
    Campos, L. T.
    de Almeida, C. E. V.
    MEDICAL PHYSICS, 2016, 43 (06) : 3464 - 3464
  • [28] Measurement of Transit Time of a Gammamed-Plus Remote Afterloading High Dose Rate Brachytherapy Source
    Supe, Sanjay S.
    Shwetha, B.
    Bijina, T. K.
    Varatharaj, C.
    Sathiyan, S.
    Ganesh, K. M.
    Arunkumar, T.
    Ravikumar, M.
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2007, 13 (02) : 55 - 63
  • [29] THEORETICAL EVALUATION OF DOSE-RATE FOR A CO-60 SOURCE IN A POOL IRRADIATOR
    CURZIO, OA
    QUARANTA, HO
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1981, 32 (04): : 256 - 257
  • [30] Determination of variation in dosimetric parameters of treatment planning with Co-60 and Ir-192 sources in high dose rate brachytherapy of cervical carcinoma
    Srivastava, Shraddha
    Singh, Navin
    Varghese, Misha
    RADIATION PHYSICS AND CHEMISTRY, 2022, 196