Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy

被引:0
|
作者
Campos, L. T.
de Almeida, C. E. V.
机构
关键词
D O I
10.1118/1.4956146
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-F-T-12
引用
收藏
页码:3464 / 3464
页数:1
相关论文
共 50 条
  • [1] Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy
    Campos, Luciana Tourinho
    Veloso de Almeida, Carlos Eduardo
    [J]. PLOS ONE, 2015, 10 (09):
  • [2] Measurements and Monte Carlo calculation of radial dose and anisotropy functions of BEBIG 60Co high-dose-rate brachytherapy source in a bounded water phantom
    Reddy, Buchapudi Rekha
    Chamberland, Marc J. P.
    Ravikumar, Manickam
    Varatharaj, Chandraraj
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (06) : 563 - 572
  • [3] A Monte Carlo investigation of the dose distribution for 60Co high dose rate brachytherapy source in water and in different media
    Badry, Hamza
    Oufni, Lhoucine
    Ouabi, Hmad
    Hirayama, Hideo
    [J]. APPLIED RADIATION AND ISOTOPES, 2018, 136 : 104 - 110
  • [4] An analytic approach to the dosimetry of a new BEBIG Co-60 high-dose-rate brachytherapy source
    Bhola, Subhalaxmi
    Selvam, T. Palani
    Sridhar, Sahoo
    Vishwakarma, Ramkrishna S.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2012, 37 (03) : 129 - 137
  • [5] Monte Carlo dosimetry of 60Co HDR brachytherapy sources
    Papagiannis, P
    Angelopoulos, A
    Pantelis, E
    Sakelliou, L
    Karaiskos, P
    Shimizu, Y
    [J]. MEDICAL PHYSICS, 2003, 30 (04) : 712 - 721
  • [6] EGSnrc Monte Carlo-aided dosimetric studies of the new BEBIG 60Co HDR brachytherapy source
    Anwarul, Islam Mohammad
    Akramuzzaman, Mir Md
    Abu Zakaria, Golam
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (03) : 148 - 156
  • [7] Dosimetric characterization of the 60Co BEBIG Co0.A86 high dose rate brachytherapy source using PENELOPE
    Guerrero, Rafael
    Almansa, Julio F.
    Torres, Javier
    Lallena, Antonio M.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2014, 30 (08): : 960 - 967
  • [8] Borosilicate glass 60Co high dose rate brachytherapy thermoluminescence dosimetry
    Nazeri, A. A. Z. Ahmad
    Sani, S. F. Abdul
    Ung, N. M.
    Almugren, K. S.
    Alkallas, F. H.
    Bradley, D. A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2021, 176
  • [9] Monte Carlo dosimetry for BEBIG Cobalt-60 brachytherapy source with gynecological applicator in the presence of inhomogeneities
    Moradi, Farhad
    Sani, Siti Fairus Abdul
    Mahyuddin, Azman
    Ung, Ngie Min
    Bradley, David Andrew
    Almugren, Kholoud
    Rashid, Hairul Azhar Abdul
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2024, 30 (03): : 145 - 151
  • [10] Monte Carlo dosimetry of the IRAsource high dose rate 192Ir brachytherapy source
    Sarabiasl, Akbar
    Ayoobian, Navid
    Jabbari, Iraj
    Poorbaygi, Hossein
    Javanshir, Mohammad Reza
    [J]. Australasian Physical and Engineering Sciences in Medicine, 2016, 39 (02): : 413 - 422