Monte Carlo dosimetry for BEBIG Cobalt-60 brachytherapy source with gynecological applicator in the presence of inhomogeneities

被引:0
|
作者
Moradi, Farhad [1 ]
Sani, Siti Fairus Abdul [2 ]
Mahyuddin, Azman [2 ]
Ung, Ngie Min [3 ]
Bradley, David Andrew [4 ,5 ]
Almugren, Kholoud [6 ]
Rashid, Hairul Azhar Abdul [1 ]
机构
[1] Multimedia Univ, Fac Engn, Jalan Multimedia, Cyberjaya 63100, Malaysia
[2] Univ Malaya, Dept Phys, Kuala Lumpur, Malaysia
[3] Univ Malaya, Fac Med, Clin Oncol Unit, Kuala Lumpur 50603, Malaysia
[4] Sunway Univ, Appl Phys & Radiat Technol Grp, CCDCU, PJ 46150, Malaysia
[5] Univ Surrey, Dept Phys, Guildford, England
[6] Princess Nourah Bint Abdulrahman Univ, Dept Phys, Riyadh, Saudi Arabia
来源
关键词
brachytherapy; Monte Carlo simulation; dosimetry; HDR; BEBIG; Co-60; DOSE-RATE BRACHYTHERAPY; TECHNICAL NOTE;
D O I
10.2478/pjmpe-2024-0017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction: High-dose-rate (HDR) Co-60 brachytherapy necessitates accurate dose calculations to minimize normal tissue toxicity and late malignancy risks. Conventionally, the American Association of Physicists in Medicine (AAPM) Task Group 43 (TG-43) formalism, utilizing table-based dose superposition, has been employed for dose calculations, overlooking tissue inhomogeneity effects. Material and methods: This study focuses on characterizing the high-dose-rate BEBIG Co-60 brachytherapy source, in combination with a gynecological applicator, using Monte Carlo simulations. The investigation is based on the model of the modified BEBIG Co-60 source (Co0.A86) implemented at the University of Malaya Medical Center. Dosimetric properties are evaluated according to AAPM TG-43 formalism, with validation against existing published data. Results: Our investigation presents comprehensive MC dosimetric properties of the high-dose-rate BEBIG Co-60 brachytherapy source, highlighting its accuracy in dose calculations compared to established data. The study also examined the impact of the applicator on depth dose calculations within a Krieger phantom and explored the influence of various tissue inhomogeneities on the depth dose. Conclusions: Our findings revealed that the applicator had a relatively minimal effect on the delivered dose, with only marginal differences observed. Furthermore, we investigated the depth doses along the central axis of the applicator, within a segment characterized by various tissue inhomogeneities where dose differences of up to 12% were observed, with the lowest and highest doses recorded within bone and adipose tissues, respectively. This study underscores the valuable role of MC simulations in estimating doses at locations where physical measurements are unfeasible, such as the intra-uterine tube surface, as well as in scenarios featuring tissue inhomogeneities.
引用
收藏
页码:145 / 151
页数:7
相关论文
共 50 条
  • [1] Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
    Campos, L. T.
    de Almeida, C. E. V.
    MEDICAL PHYSICS, 2016, 43 (06) : 3464 - 3464
  • [2] Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy
    Campos, Luciana Tourinho
    Veloso de Almeida, Carlos Eduardo
    PLOS ONE, 2015, 10 (09):
  • [3] DOSIMETRY OF A KILOCURIE COBALT-60 SOURCE
    DAVISON, S
    GOLDBLITH, SA
    PROCTOR, BE
    KAREL, M
    KAN, B
    BATES, CJ
    NUCLEONICS, 1953, 11 (07): : 22 - 26
  • [4] Dosimetry studies for an optimized reloading of a panoramic Cobalt-60 source using FLUKA Monte Carlo code
    Hammami, Imen
    Bouabidi, Ammar
    Ayadi, Asma
    Ounalli, Leila
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1064
  • [5] Independent assessment of source transit time for the BEBIG SagiNova® cobalt-60 high dose rate brachytherapy afterloader
    Abolfazl Kanani
    Sareh Karbasi
    Mohammad Amin Mosleh-Shirazi
    Australasian Physical & Engineering Sciences in Medicine, 2019, 42 : 913 - 919
  • [6] Independent assessment of source transit time for the BEBIG SagiNova® cobalt-60 high dose rate brachytherapy afterloader
    Kanani, Abolfazl
    Karbasi, Sareh
    Mosleh-Shirazi, Mohammad Amin
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2019, 42 (04) : 913 - 919
  • [7] A Monte Carlo dosimetry study using Henschke applicator for cervical brachytherapy
    Yu, Pei-Chieh
    Chao, Tsi-Chian
    Lee, Chung-Chi
    Wu, Ching-Jung
    Tung, Chuan-Jong
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 411 - 414
  • [8] Dosimetric investigation for the new BEBIG cobalt 60 source used in brachytherapy using Monte Carlo N-Particles eXtended code (MCNPX)
    Elboukhari, S.
    Yamni, K.
    Ouabi, H.
    Bouassa, T.
    Mlouk, L. A.
    INTERNATIONAL CONFERENCE ON ADVANCED MATERIALS, MICROSCOPY AND ENERGY (ICAMME) 2019, 2020, 783
  • [9] Monte Carlo calculation of dosimetry parameters for a brachytherapy source
    A. V. Belousov
    A. A. Kalachev
    A. S. Osipov
    Moscow University Physics Bulletin, 2014, 69 : 535 - 541
  • [10] Uncertainties of Monte Carlo simulation for brachytherapy source dosimetry
    Rachabatthula, V
    Meigooni, A
    MEDICAL PHYSICS, 2004, 31 (06) : 1732 - 1732