Dosimetric characterization of the 60Co BEBIG Co0.A86 high dose rate brachytherapy source using PENELOPE

被引:16
|
作者
Guerrero, Rafael [1 ]
Almansa, Julio F. [2 ]
Torres, Javier [3 ]
Lallena, Antonio M. [4 ]
机构
[1] Hosp Univ San Cecilio, Serv Radiofis & Protecc Radiol, E-18012 Granada, Spain
[2] Hosp Reg Univ Virgen de las Nieves, Serv Fis & Protecc Radiol, E-18014 Granada, Spain
[3] Hosp Gen Univ Ciudad Real, Serv Radiofis & Protecc Radiol, E-13005 Ciudad Real, Spain
[4] Univ Granada, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain
来源
关键词
Monte Carlo dosimetry; Co-60; HDR; PENELOPE; TECHNICAL NOTE; AAPM;
D O I
10.1016/j.ejmp.2014.06.039
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Co-60 sources are being used as an alternative to Ir-192 sources in high dose rate brachytherapy treatments. In a recent document from AAPM and ESTRO, a consensus dataset for the Co-60 BEBIG (model Co0.A86) high dose rate source was prepared by using results taken from different publications due to discrepancies observed among them. The aim of the present work is to provide a new calculation of the dosimetric characteristics of that Co-60 source according to the recommendations of the AAPM and ESTRO report. Radial dose function, anisotropy function, air-kerma strength, dose rate constant and absorbed dose rate in water have been calculated and compared to the results of previous works. Simulations using the two different geometries considered by other authors have been carried out and the effect of the cable density and length has been studied. (C) 2014 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:960 / 967
页数:8
相关论文
共 50 条
  • [1] Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
    Campos, L. T.
    de Almeida, C. E. V.
    MEDICAL PHYSICS, 2016, 43 (06) : 3464 - 3464
  • [2] Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy
    Campos, Luciana Tourinho
    Veloso de Almeida, Carlos Eduardo
    PLOS ONE, 2015, 10 (09):
  • [3] Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE
    Almansa, Julio F.
    Guerrero, Rafael
    Torres, Javier
    Lallena, Antonio M.
    BRACHYTHERAPY, 2017, 16 (05) : 1073 - 1080
  • [4] Dosimetric study of GZP6 60Co high dose rate brachytherapy source
    Lei, Qin
    Xu, Anjian
    Gou, Chengjun
    Wen, Yumei
    He, Donglin
    Wu, Junxiang
    Hou, Qing
    Wu, Zhangwen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 313 - 318
  • [5] A revised dosimetric characterization of 60Co BEBIG source: From single-source data to clinical dose distribution
    Abdollahi, Sara
    Dayyani, Mahdieh
    Hoseinian-Azghadi, Elie
    Miri-Hakimabad, Hashem
    Rafat-Motavalli, Laleh
    BRACHYTHERAPY, 2018, 17 (06) : 1011 - 1022
  • [6] EGSnrc Monte Carlo-aided dosimetric studies of the new BEBIG 60Co HDR brachytherapy source
    Anwarul, Islam Mohammad
    Akramuzzaman, Mir Md
    Abu Zakaria, Golam
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (03) : 148 - 156
  • [7] An analytic approach to the dosimetry of a new BEBIG Co-60 high-dose-rate brachytherapy source
    Bhola, Subhalaxmi
    Selvam, T. Palani
    Sridhar, Sahoo
    Vishwakarma, Ramkrishna S.
    JOURNAL OF MEDICAL PHYSICS, 2012, 37 (03) : 129 - 137
  • [8] BEBIG 60Co HDR brachytherapy source dosimetric parameters validation using GATE Geant4-based simulation code
    Joya, Musa
    Geraily, Ghazale
    Ghorbani, Mahdi
    Sheikhzadeh, Peyman
    Nedaie, Hassan Ali
    Arani, Mahmud Naraqi
    HELIYON, 2022, 8 (03)
  • [9] Measurements and Monte Carlo calculation of radial dose and anisotropy functions of BEBIG 60Co high-dose-rate brachytherapy source in a bounded water phantom
    Reddy, Buchapudi Rekha
    Chamberland, Marc J. P.
    Ravikumar, Manickam
    Varatharaj, Chandraraj
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (06) : 563 - 572
  • [10] Dosimetric optimization of a colpostat in a 60Co high-dose-rate brachytherapy unit for bladder sparing
    Zakariaee, Seyed Salman
    Mandavi, Seied Rabi
    BRACHYTHERAPY, 2015, 14 (01) : 37 - 45