Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy

被引:0
|
作者
Campos, L. T.
de Almeida, C. E. V.
机构
关键词
D O I
10.1118/1.4956146
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
SU-F-T-12
引用
收藏
页码:3464 / 3464
页数:1
相关论文
共 50 条
  • [21] TLD, diode and monte carlo dosimetry of an Ir-192 source for high dose-rate brachytherapy
    Kirov, AS
    Williamson, JF
    Meigooni, AS
    Zhu, Y
    PHYSICS IN MEDICINE AND BIOLOGY, 1995, 40 (12): : 2015 - 2036
  • [22] Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE
    Almansa, Julio F.
    Guerrero, Rafael
    Torres, Javier
    Lallena, Antonio M.
    BRACHYTHERAPY, 2017, 16 (05) : 1073 - 1080
  • [23] Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Pantelis, E
    Papagiannis, P
    Sakelliou, L
    Kouwenhoven, E
    Baltas, D
    MEDICAL PHYSICS, 2003, 30 (01) : 9 - 16
  • [24] Monte Carlo Dosimetric Study of the GZP 60Co Brachytherapy Source with Stainless Steel Applicator
    Wu, J.
    Wang, P.
    Wang, X.
    Kang, S.
    Li, J.
    Tang, B.
    Orlandini, L. C.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 102 (03): : E564 - E564
  • [25] Monte Carlo dosimetric study of the new BEBIG Co-60HDR source
    Ballester, F
    Granero, D
    Pérez-Calatayud, J
    Casal, E
    Agramunt, S
    Cases, R
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S138 - S138
  • [26] Monte Carlo dosimetric study of the new BEBIG Co-60HDR source
    Perez-Calatayud, J
    Granero, D
    Ballester, F
    Casal, E
    Agramunt, S
    Cases, R
    MEDICAL PHYSICS, 2005, 32 (06) : 1958 - 1958
  • [27] Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source
    Vijande, Javier
    Granero, Domingo
    Perez-Calatayud, Jose
    Ballester, Facundo
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2012, 4 (01) : 34 - 44
  • [28] Monte Carlo simulation of a typical 60Co therapy source
    Mora, GM
    Maio, A
    Rogers, DWO
    MEDICAL PHYSICS, 1999, 26 (11) : 2494 - 2502
  • [29] Monte Carlo study of a 60Co calibration field of the Dosimetry Laboratory Seibersdorf
    Hranitzky, C.
    Stadtmann, H.
    RADIATION PROTECTION DOSIMETRY, 2007, 125 (1-4) : 153 - 156
  • [30] Dosimetry of indigenously developed Ir-192 high-dose rate brachytherapy source: An EGSnrc Monte Carlo study
    Sahoo, Sridhar
    Selvam, T. Palani
    Sharma, S. D.
    Das, Trupti
    Dey, A. C.
    Patil, B. N.
    Sastri, K. V. S.
    JOURNAL OF MEDICAL PHYSICS, 2016, 41 (02) : 115 - 122