Monte Carlo dosimetric study of the new BEBIG Co-60HDR source

被引:0
|
作者
Perez-Calatayud, J
Granero, D
Ballester, F
Casal, E
Agramunt, S
Cases, R
机构
[1] ITIC, Benidorm, Spain
[2] Univ Valencia, IFIC, Valencia, Spain
关键词
D O I
10.1118/1.1997712
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The use of high dose rate brachytherapy (HDR) is a highly extended practice today, being the Ir‐192 the most widely extended isotope used for this type of practice although Co‐60 is also available for HDR. The purpose of this study is to obtain the dosimetric parameters of the Co‐60 source used by the BEBIG MultiSource remote afterloader (BEBIG GmbH, Germany) for which there is no dosimetric data available in the literature. It is recommended that accurate dose distribution data, based on a realistic geometry and on the mechanical characteristics of the source, should be obtained by an appropriate method, experimental or Monte Carlo, to be used as input in the HDR Treatment Planning System. Method and Materials: The Monte Carlo code GEANT4 has been used to obtain the TG43 parameters and the 2‐D rectangular dose rate table of the BEBIG Co‐60 HDR source. Results: The dose rate constant, radial dose function and anisotropy function have been calculated and are presented in tabular form as well as a detailed 2‐D rectangular dose rate table to check the treatment planning systems calculations. Conclusion: A Monte Carlo dosimetric study of the BEBIG [formula omitted] HDR source for which no published dosimetric data exists has been done. These dosimetric datasets can be used as input and/or to validate the TPS calculations. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:1958 / 1958
页数:1
相关论文
共 50 条
  • [1] Monte Carlo dosimetric study of the new BEBIG Co-60HDR source
    Ballester, F
    Granero, D
    Pérez-Calatayud, J
    Casal, E
    Agramunt, S
    Cases, R
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S138 - S138
  • [2] Monte Carlo dosimetric study of the BEBIG Co-60HDR source
    Ballester, F
    Granero, D
    Pérez-Calatayud, J
    Casal, E
    Agramunt, S
    Cases, R
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (21): : N309 - N316
  • [3] EGSnrc Monte Carlo-aided dosimetric studies of the new BEBIG 60Co HDR brachytherapy source
    Anwarul, Islam Mohammad
    Akramuzzaman, Mir Md
    Abu Zakaria, Golam
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2013, 5 (03) : 148 - 156
  • [4] Monte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192HDR source
    Pérez-CalatayuD, J
    Granero, D
    Ballester, F
    Casal, E
    Cases, R
    Agramunt, S
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S138 - S138
  • [5] Monte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192HDR source
    Granero, D
    Pérez-Calatayud, J
    Ballester, F
    [J]. RADIOTHERAPY AND ONCOLOGY, 2005, 76 (01) : 79 - 85
  • [6] Monte Carlo calculation of the TG-43 dosimetric parameters of a new BEBIG Ir-192HDR source
    Ballester, F
    Casal, E
    Granero, D
    Perez-Calatayud, J
    Agramunt, S
    Cases, R
    [J]. MEDICAL PHYSICS, 2005, 32 (06) : 1952 - 1952
  • [7] Technical note: Dosimetric study for the new BEBIG 60Co HDR source used in brachytherapy in water and different media using Monte Carlo N-Particle eXtended code
    Elboukhari, Said
    Yamni, Khalid
    Ouabi, Hmad
    Bouassa, Taoufiq
    Mlouk, Lahcen Ait
    [J]. APPLIED RADIATION AND ISOTOPES, 2020, 159
  • [8] Dosimetric comparison between the microSelectron HDR Ir-192 v2 source and the BEBIG Co-60 source for HDR brachytherapy using the EGSnrc Monte Carlo transport code
    Islam, M. Anwarul
    Akramuzzaman, M. M.
    Zakaria, G. A.
    [J]. JOURNAL OF MEDICAL PHYSICS, 2012, 37 (04) : 219 - 225
  • [9] Monte Carlo Dosimetric Study of the New Flexisource Co-60 High Dose Rate Source
    Vijande, J.
    Granero, D.
    Perez-Calatayud, J.
    Ballester, F.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3812 - 3812
  • [10] Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
    Campos, L. T.
    de Almeida, C. E. V.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3464 - 3464