A Monte Carlo investigation of the dose distribution for 60Co high dose rate brachytherapy source in water and in different media

被引:9
|
作者
Badry, Hamza [1 ]
Oufni, Lhoucine [1 ]
Ouabi, Hmad [2 ]
Hirayama, Hideo [3 ]
机构
[1] Sultan Moulay Slimane Univ, Fac Sci & Tech, Dept Phys, LPM ERM, BP 523, Beni Mellal 23000, Morocco
[2] Oncol Ctr Al Azhar, Rabat, Morocco
[3] High Energy Accelerator Res Org, KEK, Appl Res Lab, 1-1 Oho, Tsukuba, Ibaraki 3050801, Japan
关键词
Monte Carlo; Brachytherapy; Dose; Co-60; TECHNICAL NOTE;
D O I
10.1016/j.apradiso.2018.02.016
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, the dosimetric characterization for The BEBIG Co-60 High Dose Rate (HDR) brachytherapy source model Co0.A86 was investigated and the validity of the EGS5 Monte Carlo code to reproduce the dosimetric parameters in water phantom was checked. In addition, the dose distribution for different tissue phantoms was calculated. The BEBIG Co-60 HDR brachytherapy source was modeled using EGS5 Monte Carlo simulation code. A description of the source design, geometry and materials used in this work were provided. According to the update TG43-U1 formalism of AAPM, the air kerma strength, the dose rate constant, 2D rectangular dose distribution in water were calculated, moreover, the results of the radial dose function were obtained in water and different tissue phantoms; bone, lung, adipose tissue, breast and muscle. The obtained results were tabulated and presented in graphical formats for the comparison with available data. The calculated value of the air kerma strength of this study, 3.0419 U Bq(-1), agree well with that of the other Monte Carlo calculation. The 2D look-up along-away rectangular dose were obtained in water, the results were similar to the published data for all distances larger than 1 an, for the distances near to the source region on the transversal source axis small differences are apparent. The radial dose function were presented in graphical format for the comparison between the dose distribution in water and different tissue phantoms. The EGS5 results obtained in this study shows good consistency with the published data for the dosimetric parameters of the of the BEBIG Co-60 HDR brachytherapy source. It seems that the radial dose function calculated in water differed in tissue phantoms due to the atomic composition and densities for media that are not taken account by the TG43-U1 formalism.
引用
收藏
页码:104 / 110
页数:7
相关论文
共 50 条
  • [1] Monte Carlo Dosimetry of the 60Co Bebig High Dose Rate Source for Brachytherapy
    Campos, L. T.
    de Almeida, C. E. V.
    [J]. MEDICAL PHYSICS, 2016, 43 (06) : 3464 - 3464
  • [2] Monte Carlo Dosimetry of the 60Co BEBIG High Dose Rate for Brachytherapy
    Campos, Luciana Tourinho
    Veloso de Almeida, Carlos Eduardo
    [J]. PLOS ONE, 2015, 10 (09):
  • [3] A Monte Carlo investigation of the dose distribution for new I-125 Low Dose Rate brachytherapy source in water and in different media
    Fardi, Zeinab
    Taherparvar, Payvand
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2019, 25 (01): : 15 - 22
  • [4] Measurements and Monte Carlo calculation of radial dose and anisotropy functions of BEBIG 60Co high-dose-rate brachytherapy source in a bounded water phantom
    Reddy, Buchapudi Rekha
    Chamberland, Marc J. P.
    Ravikumar, Manickam
    Varatharaj, Chandraraj
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2019, 11 (06) : 563 - 572
  • [5] A Monte Carlo Dosimetric Parameters of the 60Co High Dose Rate Brachytherapy and Investigation of TG43 Dose Accuracy in Different Media Using GATE v8.2 Code
    Ait-Mlouk, Lahcen
    Khalis, Mohammed
    Ouabi, Hmad
    Asnaoui, Hassan
    Elboukhari, Said
    [J]. MOSCOW UNIVERSITY PHYSICS BULLETIN, 2021, 76 (SUPPL 1) : S68 - S79
  • [6] A Monte Carlo Dosimetric Parameters of the 60Co High Dose Rate Brachytherapy and Investigation of TG43 Dose Accuracy in Different Media Using GATE v8.2 Code
    Lahcen Ait-Mlouk
    Mohammed Khalis
    Hmad Ouabi
    Hassan Asnaoui
    Said Elboukhari
    [J]. Moscow University Physics Bulletin, 2021, 76 : S68 - S79
  • [7] Dosimetric study of GZP6 60Co high dose rate brachytherapy source
    Lei, Qin
    Xu, Anjian
    Gou, Chengjun
    Wen, Yumei
    He, Donglin
    Wu, Junxiang
    Hou, Qing
    Wu, Zhangwen
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 313 - 318
  • [8] Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE
    Almansa, Julio F.
    Guerrero, Rafael
    Torres, Javier
    Lallena, Antonio M.
    [J]. BRACHYTHERAPY, 2017, 16 (05) : 1073 - 1080
  • [9] Monte Carlo dosimetric study of the Flexisource Co-60 high dose rate source
    Vijande, Javier
    Granero, Domingo
    Perez-Calatayud, Jose
    Ballester, Facundo
    [J]. JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2012, 4 (01) : 34 - 44
  • [10] Borosilicate glass 60Co high dose rate brachytherapy thermoluminescence dosimetry
    Nazeri, A. A. Z. Ahmad
    Sani, S. F. Abdul
    Ung, N. M.
    Almugren, K. S.
    Alkallas, F. H.
    Bradley, D. A.
    [J]. APPLIED RADIATION AND ISOTOPES, 2021, 176