High dose-rate brachytherapy source position quality assurance using radiochromic film

被引:45
|
作者
Evans, M. D. C. [1 ]
Devic, S. [1 ]
Podgorsak, E. B. [1 ]
机构
[1] McGill Univ, Montreal Gen Hosp, Ctr Hlth, Dept Med Phys, Montreal, PQ H3G 1A4, Canada
关键词
brachytherapy; quality assurance; radiochromic film;
D O I
10.1016/j.meddos.2006.10.001
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Traditionally, radiographic film has been used to verify high-dose-rate brachytherapy source position accuracy by co-registering autoradiographic and diagnostic images of the associated applicator. Filmless PACS-based clinics that do not have access to radiographic film and wet developers may have trouble performing this quality assurance test in a simple and practical manner. We describe an alternative method for quality assurance using radiochromic-type film. In addition to being easy and practical to use, radiochromic film has some advantages in comparison with traditional radiographic film when used for HDR brachytherapy quality assurance. (C) 2007 American Association of Medical Dosimetrists.
引用
收藏
页码:13 / 15
页数:3
相关论文
共 50 条
  • [1] A Study of Computed Radiography for High Dose-Rate Brachytherapy Source Position Quality Assurance
    Piriyasang, D.
    Tangboonduangjit, P.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [2] The use of improved radiochromic film for in vivo quality assurance of high dose rate brachytherapy
    Pai, S
    Reinstein, LE
    Gluckman, G
    Xu, ZG
    Weiss, T
    [J]. MEDICAL PHYSICS, 1998, 25 (07) : 1217 - 1221
  • [3] Radiochromic film dosimetry of a high dose rate beta source for intravascular brachytherapy
    Duggan, DM
    Coffey, CW
    Lobdell, JL
    Schell, MC
    [J]. MEDICAL PHYSICS, 1999, 26 (11) : 2461 - 2464
  • [4] Radiochromic film-based quality assurance for CT-based high-dose-rate brachytherapy
    Asgharizadeh, Saeid
    Bekerat, Hamed
    Syme, Alasdair
    Aldelaijan, Saad
    DeBlois, Francois
    Te Vuong
    Evans, Michael
    Seuntjens, Jan
    Devic, Slobodan
    [J]. BRACHYTHERAPY, 2015, 14 (04) : 578 - 585
  • [5] Performance Evaluation of a Novel Quality Assurance Device for High Dose-Rate Brachytherapy
    Sensoy, L.
    Bassiri, N.
    De Jean, P.
    Benedict, S.
    [J]. MEDICAL PHYSICS, 2021, 48 (06)
  • [6] In vivo dosimetry of high dose rate brachytherapy using an improved radiochromic film
    Parsai, E
    Feldmeier, J
    Ye, S
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1206 - 1206
  • [7] A quality assurance test tool for high dose-rate remote afterloading brachytherapy units
    Li, ZF
    Mitchell, TP
    Palta, JR
    Liu, CR
    [J]. MEDICAL PHYSICS, 1998, 25 (02) : 232 - 235
  • [8] A quality assurance test tool for high dose-rate remote afterloading brachytherapy units
    Department of Radiation Oncology, University of Florida, College of Medicine, Gainesville, FL 32610, United States
    [J]. Med. Phys., 2 (232-235):
  • [9] Quality assurance measurements for high-dose-rate brachytherapy without film
    Jursinic, Paul A.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (01): : 246 - 261
  • [10] An Automated Treatment Plan Quality Assurance Program for Tandem and Ovoid High Dose-Rate Brachytherapy
    Tan, J.
    Shi, F.
    Hrycushko, B.
    Medin, P.
    Stojadinovic, S.
    Pompos, A.
    Yang, M.
    Albuquerque, K.
    Jia, X.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3594 - 3594