Monte Carlo dosimetric characterization of the Flexisource Co-60 high-dose-rate brachytherapy source using PENELOPE

被引:6
|
作者
Almansa, Julio F. [1 ]
Guerrero, Rafael [1 ]
Torres, Javier [2 ]
Lallena, Antonio M. [3 ]
机构
[1] Complejo Hosp Univ Granada, Serv Fis & Protecc Radiol, Granada, Spain
[2] Hosp Gen Univ Ciudad Real, Serv Radiofis & Protecc Radiol, Ciudad Real, Spain
[3] Univ Granada, Dept Fis Atom Mol & Nucl, E-18071 Granada, Spain
关键词
Monte Carlo dosimetry; Brachytherapy; (CO)-C-60; HDR; PENELOPE; TECHNICAL NOTE; AAPM; PARAMETERS;
D O I
10.1016/j.brachy.2017.04.245
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
PURPOSE: Co-60 sources have been commercialized as an alternative to Ir-192 sources for high dose-rate (HDR) brachytherapy. One of them is the Flexisource Co-60 HDR source manufactured by Elekta. The only available dosimetric characterization of this source is that of Vijande et al. [J Contemp Brachytherapy 2012; 4:34-44], whose results were not included in the AAPM/ESTRO consensus document. In that work, the dosimetric quantities were calculated as averages of the results obtained with the Geant4 and PENELOPE Monte Carlo (MC) codes, though for other sources, significant differences have been quoted between the values obtained with these two codes. The aim of this work is to perform the dosimetric characterization of the Flexisource Co-60 HDR source using PENELOPE. METHODS AND MATERIALS: The MC simulation code PENELOPE (v. 2014) has been used. Following the recommendations of the AAPM/ESTRO report, the radial dose function, the anisotropy function, the air-kerma strength, the dose rate constant, and the absorbed dose rate in water have been calculated. RESULTS: The results we have obtained exceed those of Vijande et al. In particular, the absorbed dose rate constant is similar to 0.85% larger. A similar difference is also found in the other dosimetric quantities. The effect of the electrons emitted in the decay of Co-60, usually neglected in this kind of simulations, is significant up to the distances of 0.25 cm from the source. CONCLUSIONS: The systematic and significant differences we have found between PENELOPE results and the average values found by Vijande et al. point out that the dosimetric characterizations carried out with the various MC codes should be provided independently. (C) 2017 American Brachytherapy Society. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:1073 / 1080
页数:8
相关论文
共 50 条
  • [21] Geometric Optimizations of a Directional High Dose Rate Brachytherapy Source Using Monte Carlo
    Heredia, A.
    Henderson, D.
    Thomadsen, B.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [22] A Monte Carlo investigation of the dosimetric characteristics of the VariSource 192Ir high dose rate brachytherapy source
    Karaiskos, P
    Angelopoulos, A
    Baras, P
    Sakelliou, L
    Sandilos, P
    Dardoufas, K
    Vlachos, L
    MEDICAL PHYSICS, 1999, 26 (08) : 1498 - 1502
  • [23] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Sadeghi, Mahdi
    Taghdiri, Fatemah
    Saidi, Pooneh
    JAPANESE JOURNAL OF RADIOLOGY, 2011, 29 (05) : 324 - 329
  • [24] Dosimetric characteristics of the 192Ir high-dose-rate afterloading brachytherapy source
    Mahdi Sadeghi
    Fatemah Taghdiri
    Pooneh Saidi
    Japanese Journal of Radiology, 2011, 29 : 324 - 329
  • [25] Dosimetric analysis of Co-60 source based high dose rate (HDR) brachytherapy: A case series of ten patients with carcinoma of the uterine cervix
    Gurjar, Om Prakash
    Batra, Manika
    Bagdare, Priyusha
    Kaushik, Sandeep
    Tyagi, Atul
    Naik, Ayush
    Bhandari, Virendra
    Gupta, Krishna Lal
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2016, 21 (03) : 201 - 206
  • [26] Dosimetric study of GZP6 60Co high dose rate brachytherapy source
    Lei, Qin
    Xu, Anjian
    Gou, Chengjun
    Wen, Yumei
    He, Donglin
    Wu, Junxiang
    Hou, Qing
    Wu, Zhangwen
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (04): : 313 - 318
  • [27] Dosimetric investigation of a new high dose rate 192Ir brachytherapy source, IRAsource, by Monte Carlo method
    Rostami, Atefeh
    Hoseini, Mahdi
    Ghorbani, Mahdi
    Knaup, Courtney
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2020, 25 (01) : 139 - 145
  • [28] PATIENT SPECIFIC MONTE CARLO DOSE CALCULATIONS OF HIGH-DOSE-RATE BRACHYTHERAPY OF PARTIAL BREAST IRRADIATION
    Terribilini, D.
    Isaak, B.
    Manser, P.
    Frei, D.
    Volken, W.
    Mini, R.
    Fix, M. K.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S517 - S517
  • [29] Monte Carlo dosimetric characterization of a new high dose rate 169Yb brachytherapy source and independent verification using a multipoint plastic scintillator detector
    Famulari, Gabriel
    Linares Rosales, Haydee M.
    Dupere, Justine
    Medich, David C.
    Beaulieu, Luc
    Enger, Shirin A.
    MEDICAL PHYSICS, 2020, 47 (09) : 4563 - 4573
  • [30] Implementation of the Sievert integral for the calculation of dose distribution around the BEBIG Co-60 high dose rate brachytherapy source
    Dumenya, Castrol
    Hasford, Francis
    Tagoe, Samuel Nii Adu
    Sasu, Evans
    Pokoo-Aikins, Mark
    Asamanyuah, Belinda Buermle
    Amuasi, John Humphrey
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2022, 28 (02): : 90 - 98