Phantom Study for Volume-of-Interest Breast Imaging using Differential Phase Contrast Cone Beam CT (DPC-CBCT)

被引:0
|
作者
Liu, Jiangkun [1 ]
Ning, Ruola [1 ,2 ]
Cai, Weixing [2 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[2] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
关键词
Differential phase contrast; Cone beam CT; Volume of interest; Breast imaging;
D O I
10.1117/12.2007159
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Differential phase contrast (DPC) imaging is reported to be able to deliver higher contrast-to-noise ratio (CNR) compared to attenuation-based x-ray imaging technologies. Due to the nature of attenuation contrast, the conventional cone beam CT (CBCT) technology has limitations in characterizing breast lesions with sufficiently high contrast and spatial resolution. As an alternative, the grating-based DPC-CBCT technology is potentially a powerful tool for breast imaging. However, limited by current grating fabrication techniques, a full field-of-view (FOV) that covers the whole breast is not practical at present. Previously by our group, a volume-of-interest (VOI) imaging method, which incorporates DPC-CBCT into a dedicated attenuation-based CBCT imaging system, was presented. In the method, the CBCT scan was performed to localize the suspicious volume and then a VOI scan by DPC-CBCT characterized the suspicious volume with higher contrast and resolution. In this work, we investigated the performance of DPC-CBCT VOI imaging by performing a phantom study using our bench-top DPC-CBCT system with a hospital-grade X-ray tube. A cylinder water phantom with a size of over twice of the FOV of our DPC-CBCT system was designed. The phantom contains four different materials and it was scanned at four different dose levels. In thick object scanning, phase wrapping errors cause artifacts for DPC-CBCT VOI imaging. A low-pass filter was designed to reduce the artifacts. In order to compare the DPC-CBCT VOI with attenuation-based CBCT, the scanning data were used to reconstruct both phase coefficient image and attenuation coefficient image. The reconstructed images will be quantitatively and visually evaluated with regards to contrast, noise level and artifacts.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Cone-beam volume CT mammographic imaging: feasibility study
    Chen, BA
    Ning, RL
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 655 - 664
  • [42] Automated planning of breast radiotherapy using cone beam CT imaging
    Amit, Guy
    Purdie, Thomas G.
    MEDICAL PHYSICS, 2015, 42 (02) : 770 - 779
  • [43] Comparing Concordance Between Contrast-Enhanced Cone Beam Breast CT and Contrast-Enhanced MR Imaging of the Breast
    Seifert, P.
    Destounis, S.
    Somerville, P.
    Murphy, P.
    Logan-Young, W.
    Arieno, A.
    Morgan, R.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (05)
  • [44] Evaluation of scattered radiation effect on breast cone-beam CT image: A phantom study
    Kwan, A
    Boone, J
    Yang, K
    Shah, N
    MEDICAL PHYSICS, 2005, 32 (06) : 2064 - 2064
  • [45] Investigation of Moire Pattern-based Phase Retrieval Approach for Differential Phase-contrast Cone Beam CT Imaging Using a Hospital-grade Tube
    Cai, Weixing
    Ning, Ruola
    Yu, Yang
    Liu, Jiangkun
    Conover, David
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [46] Evaluation of reconstruction accuracy of cone beam volume CT breast imaging for different scanning orbits
    Ning, R
    Lu, XG
    Chen, B
    Yu, Y
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 1001 - 1009
  • [47] Development of a 4D digital phantom for Cone-Beam CT (CBCT) imaging on the Varian On-Board Imager (OBI)
    Amin, Adam Tan Mohd
    Mokri, Siti Salasiah
    Ahmad, Rozilawati
    Abd Rahni, Ashrani Aizzuddin
    INTERNATIONAL JOURNAL OF INTEGRATED ENGINEERING, 2019, 11 (03): : 90 - 99
  • [48] A Phantom Study of Accuracy of Four-Dimensional Cone-Beam CT (4D-CBCT) Vs. Three-Dimensional Cone Beam CT (3D-CBCT) in Image Guided Radiotherapy
    He, R.
    Morris, B.
    Duggar, N.
    Markovich, A.
    Standford, J.
    Lu, J.
    Yang, C.
    MEDICAL PHYSICS, 2016, 43 (06) : 3365 - 3365
  • [49] Design and Construction of a Micro-focus In-line Phase-contrast Cone Beam CT (PC-CBCT) System for Soft Tissue Imaging
    Cai, Weixing
    Ning, Ruola
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [50] Patient-bounded extrapolation using low-dose priors for volume-of-interest imaging in C-arm CT
    Xia, Y.
    Bauer, S.
    Maier, A.
    Berger, M.
    Hornegger, J.
    MEDICAL PHYSICS, 2015, 42 (04) : 1787 - 1796