Phantom Study for Volume-of-Interest Breast Imaging using Differential Phase Contrast Cone Beam CT (DPC-CBCT)

被引:0
|
作者
Liu, Jiangkun [1 ]
Ning, Ruola [1 ,2 ]
Cai, Weixing [2 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[2] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
关键词
Differential phase contrast; Cone beam CT; Volume of interest; Breast imaging;
D O I
10.1117/12.2007159
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Differential phase contrast (DPC) imaging is reported to be able to deliver higher contrast-to-noise ratio (CNR) compared to attenuation-based x-ray imaging technologies. Due to the nature of attenuation contrast, the conventional cone beam CT (CBCT) technology has limitations in characterizing breast lesions with sufficiently high contrast and spatial resolution. As an alternative, the grating-based DPC-CBCT technology is potentially a powerful tool for breast imaging. However, limited by current grating fabrication techniques, a full field-of-view (FOV) that covers the whole breast is not practical at present. Previously by our group, a volume-of-interest (VOI) imaging method, which incorporates DPC-CBCT into a dedicated attenuation-based CBCT imaging system, was presented. In the method, the CBCT scan was performed to localize the suspicious volume and then a VOI scan by DPC-CBCT characterized the suspicious volume with higher contrast and resolution. In this work, we investigated the performance of DPC-CBCT VOI imaging by performing a phantom study using our bench-top DPC-CBCT system with a hospital-grade X-ray tube. A cylinder water phantom with a size of over twice of the FOV of our DPC-CBCT system was designed. The phantom contains four different materials and it was scanned at four different dose levels. In thick object scanning, phase wrapping errors cause artifacts for DPC-CBCT VOI imaging. A low-pass filter was designed to reduce the artifacts. In order to compare the DPC-CBCT VOI with attenuation-based CBCT, the scanning data were used to reconstruct both phase coefficient image and attenuation coefficient image. The reconstructed images will be quantitatively and visually evaluated with regards to contrast, noise level and artifacts.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Cone-beam volume CT breast imaging: Feasibility study
    Chen, B
    Ning, R
    MEDICAL PHYSICS, 2002, 29 (05) : 755 - 770
  • [22] Volume-of-Interest Assessment of Oncologic Response Using F-18-FDG PET/CT: A Phantom Study
    Perez-Lopez, Berenice
    Fabricio Vega-Gonzalez, Ivan
    Estrada-Lobato, Enrique
    Jesus Perez-Molina, J.
    Miriam Torres-Mendoza, Blanca
    Alberto Medina, Luis
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2011, 39 (01) : 14 - 18
  • [23] Dose saving and scatter reduction in Volume-of-Interest (VON) cone beam CT-work in progres
    Lai, Chao-Jen
    Shaw, Chris C.
    Chen, Lingyun
    Liu, Xinming
    Han, Tao
    Wang, Tianpeng
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [24] Detection performance study for cone-beam differential phase contrast CT
    Li, Ke
    Bevins, Nicholas
    Zambelli, Joseph
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [25] Iodine contrast cone beam CT imaging of breast cancer
    Partain, Larry
    Prionas, Stavros
    Seppi, Edward
    Virshup, Gary
    Roos, Gerhard
    Sutherland, Robert
    Boone, John
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [26] Quantify total activity by volume-of-interest expansion with clinical SPECT/CT systems, a phantom study
    Bian, Junguo
    James, Judy R.
    Wagner, Robert
    Halama, James
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (01):
  • [27] Dual Energy Differential Phase Contrast CT (DE-DPC-CT) Imaging
    Ji, Xu
    Zhang, Ran
    Li, Ke
    Chen, Guang-Hong
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (11) : 3278 - 3289
  • [28] An Investigation of KV CBCT Image Quality and Dose Reduction for Volume-Of-Interest Imaging Using Dynamic Collimation
    Parsons, D.
    Robar, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 542 - 542
  • [29] An investigation of kV CBCT image quality and dose reduction for volume-of-interest imaging using dynamic collimation
    Parsons, David
    Robar, James L.
    MEDICAL PHYSICS, 2015, 42 (09) : 5258 - 5269
  • [30] Real time flat panel detector-based cone beam volume CT breast imaging: phantom and specimen study
    Ning, R
    Conover, D
    Yu, Y
    Schiffhauer, L
    Lu, XH
    Cullinan, J
    Robinson, A
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 181 - 190