Phantom Study for Volume-of-Interest Breast Imaging using Differential Phase Contrast Cone Beam CT (DPC-CBCT)

被引:0
|
作者
Liu, Jiangkun [1 ]
Ning, Ruola [1 ,2 ]
Cai, Weixing [2 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[2] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
关键词
Differential phase contrast; Cone beam CT; Volume of interest; Breast imaging;
D O I
10.1117/12.2007159
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Differential phase contrast (DPC) imaging is reported to be able to deliver higher contrast-to-noise ratio (CNR) compared to attenuation-based x-ray imaging technologies. Due to the nature of attenuation contrast, the conventional cone beam CT (CBCT) technology has limitations in characterizing breast lesions with sufficiently high contrast and spatial resolution. As an alternative, the grating-based DPC-CBCT technology is potentially a powerful tool for breast imaging. However, limited by current grating fabrication techniques, a full field-of-view (FOV) that covers the whole breast is not practical at present. Previously by our group, a volume-of-interest (VOI) imaging method, which incorporates DPC-CBCT into a dedicated attenuation-based CBCT imaging system, was presented. In the method, the CBCT scan was performed to localize the suspicious volume and then a VOI scan by DPC-CBCT characterized the suspicious volume with higher contrast and resolution. In this work, we investigated the performance of DPC-CBCT VOI imaging by performing a phantom study using our bench-top DPC-CBCT system with a hospital-grade X-ray tube. A cylinder water phantom with a size of over twice of the FOV of our DPC-CBCT system was designed. The phantom contains four different materials and it was scanned at four different dose levels. In thick object scanning, phase wrapping errors cause artifacts for DPC-CBCT VOI imaging. A low-pass filter was designed to reduce the artifacts. In order to compare the DPC-CBCT VOI with attenuation-based CBCT, the scanning data were used to reconstruct both phase coefficient image and attenuation coefficient image. The reconstructed images will be quantitatively and visually evaluated with regards to contrast, noise level and artifacts.
引用
收藏
页数:8
相关论文
共 50 条
  • [11] Volume-of-interest (VOI) cone beam CT with dual resolution image acquisition
    Chen, L.
    Shaw, C.
    Meng, Y.
    Altunbas, M.
    Wang, T.
    Tu, S.
    Liu, X.
    Lai, C.
    MEDICAL PHYSICS, 2006, 33 (06) : 2000 - 2000
  • [12] Evaluation of differential phase contrast cone beam CT imaging system
    Liu, Jiangkun
    Cai, Weixing
    Ning, Ruola
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (03) : 357 - 372
  • [13] Magnitude of Scattered Radiation and Dose Efficiency in Volume-Of-Interest (VOI) Cone Beam CT
    Lai, C.
    Chen, L.
    Han, T.
    Liu, X.
    Shen, Y.
    Wang, T.
    Shaw, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [14] Flat panel detector-based cone beam volume CT breast imaging: Phantom study
    Ning, R
    Chen, B
    Conover, D
    McHugh, L
    Cullinan, JA
    Robinson, AE
    RADIOLOGY, 2001, 221 : 544 - 544
  • [15] High resolution dual detector volume-of-interest cone beam breast CT-Demonstration with a bench top system
    Shen, Youtao
    Yi, Ying
    Zhong, Yuncheng
    Lai, Chao-Jen
    Liu, Xinming
    You, Zhicheng
    Ge, Shuaiping
    Wang, Tianpeng
    Shaw, Chris C.
    MEDICAL PHYSICS, 2011, 38 (12) : 6429 - 6442
  • [16] Feasibility Study of Spectral Imaging for Differential Phase Contrast Cone Beam CT: Computer Simulations
    Cai, Weixing
    Ning, Ruola
    Liu, Jiangkun
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [17] Improving image quality and reducing dose with 2.5 MV diamond target volume-of-interest cone beam CT imaging
    Borsavage, Jennifer M.
    Cherpak, Amanda J.
    Robar, James L.
    MEDICAL PHYSICS, 2022, 49 (12) : 7661 - 7671
  • [18] Volume-of-Interest Reconstruction from Severely Truncated Data in Dental Cone-Beam CT
    Zhang, Zheng
    Kusnoto, Budi
    Han, Xiao
    Sidky, E. Y.
    Pan, Xiaochuan
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [19] Flat panel detector-based cone beam volume CT breast imaging: preliminary phantom study
    Ning, RL
    Chen, BA
    Conover, D
    McHugh, L
    Cullinan, J
    Yu, RF
    MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 : 601 - 610
  • [20] Flat panel detector-based cone beam volume CT breast imaging: phantom and specimen study
    Ning, R
    Conover, D
    Chen, B
    Schiffhauer, L
    Cullinan, J
    Ning, Y
    Robinson, A
    MEDICAL IMAGING 2002: PHYSICS OF MEDICAL IMAGING, 2002, 4682 : 218 - 227