Phantom Study for Volume-of-Interest Breast Imaging using Differential Phase Contrast Cone Beam CT (DPC-CBCT)

被引:0
|
作者
Liu, Jiangkun [1 ]
Ning, Ruola [1 ,2 ]
Cai, Weixing [2 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[2] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
关键词
Differential phase contrast; Cone beam CT; Volume of interest; Breast imaging;
D O I
10.1117/12.2007159
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Differential phase contrast (DPC) imaging is reported to be able to deliver higher contrast-to-noise ratio (CNR) compared to attenuation-based x-ray imaging technologies. Due to the nature of attenuation contrast, the conventional cone beam CT (CBCT) technology has limitations in characterizing breast lesions with sufficiently high contrast and spatial resolution. As an alternative, the grating-based DPC-CBCT technology is potentially a powerful tool for breast imaging. However, limited by current grating fabrication techniques, a full field-of-view (FOV) that covers the whole breast is not practical at present. Previously by our group, a volume-of-interest (VOI) imaging method, which incorporates DPC-CBCT into a dedicated attenuation-based CBCT imaging system, was presented. In the method, the CBCT scan was performed to localize the suspicious volume and then a VOI scan by DPC-CBCT characterized the suspicious volume with higher contrast and resolution. In this work, we investigated the performance of DPC-CBCT VOI imaging by performing a phantom study using our bench-top DPC-CBCT system with a hospital-grade X-ray tube. A cylinder water phantom with a size of over twice of the FOV of our DPC-CBCT system was designed. The phantom contains four different materials and it was scanned at four different dose levels. In thick object scanning, phase wrapping errors cause artifacts for DPC-CBCT VOI imaging. A low-pass filter was designed to reduce the artifacts. In order to compare the DPC-CBCT VOI with attenuation-based CBCT, the scanning data were used to reconstruct both phase coefficient image and attenuation coefficient image. The reconstructed images will be quantitatively and visually evaluated with regards to contrast, noise level and artifacts.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Peripheral dose sparing of volume-of-interest CBCT using a novel 2.5 MV low-Z beam
    Borsavage, J.
    Cherpak, A.
    Robar, J.
    RADIOTHERAPY AND ONCOLOGY, 2022, 170 : S1418 - S1419
  • [32] Editorial comment: cone-beam and phase contrast CT: new horizons in breast imaging?
    Boss, Andreas
    EUROPEAN RADIOLOGY, 2018, 28 (09) : 3729 - 3730
  • [33] Editorial comment: cone-beam and phase contrast CT: new horizons in breast imaging?
    Andreas Boss
    European Radiology, 2018, 28 : 3729 - 3730
  • [34] Dose saving and scatter reduction in volume-of-interest (VOI) cone beam CT - A Monte Carlo simulation study with geant4
    Chen, L.
    Shaw, C.
    Altunbas, M.
    Lai, C.
    Ding, X.
    Liu, X.
    Han, T.
    Wang, T.
    MEDICAL PHYSICS, 2007, 34 (06) : 2562 - 2563
  • [35] Cone-Beam CT for Breast Specimens in Surgery: The Phantom Study
    Thongvigitmanee, Saowapak S.
    Aootaphao, Sorapong
    Thanasupsombat, Chalinee
    Kiang-ia, Atthasak
    Narkbuakaew, Walita
    Wangkaoom, Kongyot
    Junhunee, Parinya
    Laohawiriyakamol, Suphawat
    Puttawibul, Puttisak
    Thajchayapong, Pairash
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [36] Scatter correction for clinical cone beam CT breast imaging based on breast phantom studies
    Cai, Weixing
    Ning, Ruola
    Conover, David
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2011, 19 (01) : 91 - 109
  • [37] Comparison of Breast-Centered and Volume-Of-Interest (VOI)-Centered VOI Cone Beam CT Techniques - Dose and Scatter Considerations with Monte Carlo Simulation
    Chen, L.
    Lai, C.
    Han, T.
    Liu, X.
    Shen, Y.
    Wang, T.
    Shaw, C.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [38] Image reconstruction of cone-beam differential phase contrast CT using phase line integral retrieval
    Fu, Jian
    Li, Chen
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2015, 23 : 491 - 496
  • [39] Contrast enhanced imaging of human meniscus using cone beam CT
    Honkanen, J. T. J.
    Danso, E. K.
    Suomalainen, J. -S.
    Tiitu, V.
    Korhonen, R. K.
    Jurvelin, J. S.
    Toyras, J.
    OSTEOARTHRITIS AND CARTILAGE, 2015, 23 (08) : 1367 - 1376
  • [40] Comparing Effective Doses for Hip Imaging Using Cone Beam CT (CBCT) and Multidetector CT (MDCT)
    Dave, J.
    Jiang, X.
    Machado, P.
    Roth, C.
    Minch, T.
    MEDICAL PHYSICS, 2022, 49 (06) : E629 - E629