Design and Construction of a Micro-focus In-line Phase-contrast Cone Beam CT (PC-CBCT) System for Soft Tissue Imaging

被引:4
|
作者
Cai, Weixing [1 ]
Ning, Ruola [1 ]
机构
[1] Univ Rochester, Dept Imaging Sci, Rochester, NY 14642 USA
关键词
Phase contrast; in-line; cone beam CT; MICROTOMOGRAPHY;
D O I
10.1117/12.844379
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In recent years, the in-line phase-contrast (in-line PC) technique has been implemented using synchrotrons and micro-focus x-ray tubes for soft tissue imaging as the in-line PC's image quality enhancement. In this study, a new in-line phase-contrast cone-beam CT (PC-CBCT) system has been designed and tested in our lab to produce higher image quality enhancement. The PC-CBCT system consists of a micro-focus x-ray tube, a high-resolution detector and a rotating phantom holder. The nominal focal spot size is 9 microns, which is expected to produce partially coherent x-rays. The detector system has a phosphor screen, an optical fiber coupling unit and a CMOS chip with an effective pixel pitch of 22.5 microns. Some key system parameters, including tube voltage (or x-ray spectrum), source-to-object distance and object-to-detector distance were balanced and optimized to achieve enough spatial coherence and degree of interference to acquire edge-enhanced phase-contrast images as projection images. The phantom holder was rotated for 360 degrees with a step of 1.2 degrees, and during the rotation in-line PC images were acquired at all angular positions. The FDK algorithm was applied to compute the reconstruction using the edge-enhanced PC images. Small soft tissue samples (breast tissues and animal organs) were scanned and reconstructed. The tomographic images showed enhanced structure edges and details..
引用
收藏
页数:10
相关论文
共 9 条
  • [1] Performance Evaluation of a Differential Phase-contrast Cone-beam (DPC-CBCT) System for Soft Tissue Imaging
    Yu, Yang
    Ning, Ruola
    Cai, Weixing
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [2] In-line phase contrast imaging using a micro-focus X-ray source
    Yu Ai-Min
    Li Zheng
    Zhang Di
    Huang Zhi-Feng
    HIGH ENERGY PHYSICS AND NUCLEAR PHYSICS-CHINESE EDITION, 2006, 30 (11): : 1119 - 1122
  • [3] Soft tissue small avascular tumor imaging with x-ray phase-contrast micro-CT in-line holography
    Nesterets, Yakov
    Gureyev, Tim
    Stevenson, Andrew
    Pogany, Andrew
    Wilkins, Steve
    Kincaid, Russell
    Ye, Hongwei
    Vogelsang, Levon
    Lipson, Edward
    Coman, Loana
    Fourmaux, Sylvain
    Kieffer, Jean-Claude
    Krol, Andrzej
    MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
  • [4] Investigation of Source Grating Stepping for Differential Phase-contrast Cone Beam CT (DPC-CBCT) System
    Cai, Weixing
    Yu, Yang
    Ning, Ruola
    Liu, Jiangkun
    Conover, David
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [5] System design considerations for a x-ray phase-contrast imaging system based on in-line holography
    Wu, XZ
    Liu, H
    Yan, AM
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT II , PTS 1 AND 2, 2005, 5630 : 130 - 140
  • [6] In-Line Method of X-ray Phase-Contrast Micro-CT Using a Wide-Focus Laboratory Source
    Yu. S. Krivonosov
    A. V. Buzmakov
    V. E. Asadchikov
    A. A. Fyodorova
    Crystallography Reports, 2023, 68 : 203 - 209
  • [7] In-Line Method of X-ray Phase-Contrast Micro-CT Using a Wide-Focus Laboratory Source
    Krivonosov, Yu. S.
    Buzmakov, A. V.
    Asadchikov, V. E.
    Fyodorova, A. A.
    CRYSTALLOGRAPHY REPORTS, 2023, 68 (02) : 203 - 209
  • [8] Preliminary study of a phase-contrast cone-beam computed tomography system: the edge-enhancement effect in the tomographic reconstruction of in-line holographic images
    Cai, Weixing
    Ning, Ruola
    OPTICAL ENGINEERING, 2008, 47 (03)
  • [9] Design and construction of a flat panel-based cone beam computed tomography (FPD-CBCT) imaging system through the adaptation of a commercially available CT system: Recent data
    Conover, D
    Ning, RL
    MEDICAL IMAGING 2004: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2004, 5368 : 610 - 615