Investigation of Source Grating Stepping for Differential Phase-contrast Cone Beam CT (DPC-CBCT) System

被引:2
|
作者
Cai, Weixing [1 ]
Yu, Yang [2 ]
Ning, Ruola [1 ,2 ]
Liu, Jiangkun [2 ]
Conover, David
机构
[1] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
[2] Univ Rochester, Dept Elect & Comp Engn, 601 Elmwood Ave, Rochester, NY 14627 USA
基金
美国国家科学基金会;
关键词
Phase Contrast; Differential Phase Contrast; Phase Stepping; Cone Beam CT;
D O I
10.1117/12.911422
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Differential phase contrast (DPC) imaging, which utilizes phase shift information of X-ray, has the potential of dramatically increasing the contrast in biological sample imaging compared to attenuation-based method that relies on X-ray absorption information, since the X-ray phase is much more sensitive than the attenuation during transmission. In a DPC imaging system, the phase stepping method is widely used to obtain DPC images: at each angle the phase grating is shifted incrementally to produce a set of images and then the so obtained images are used to retrieve DPC image. However, DPC imaging requires a high mechanical precision to perform phase stepping, which is generally one order higher than the period of phase grating. Given that phase grating period is generally 2-4 um, the requirement of mechanical accuracy and stability are very demanding (<0.5um) and difficult to meet in a system with rotating gantry. In this paper, we present a method that is able to greatly relax the requirement of mechanical accuracy and stability by stepping the source grating rather than the analyzer grating. This method is able to increase the system's mechanical tolerance without compromising image quality and make it feasible to install the system on a rotating gantry to perform differential phase-contrast cone beam CT (DPC-CBCT). It is also able to increase the grating shifting precision and as a result improve the reconstructed image quality. Mechanical tolerance investigation and image quality investigation at different phase stepping schemes and different dose levels will be carried out on both the original modality and the new modality, the results will be evaluated and compared. We will deliberately create random mechanical errors in phase stepping and evaluate the resulting DPC images and DPC-CBCT reconstructions. The contrast, noise level and sharpness will be evaluated to assess the influence of mechanical errors. By stepping the source grating, the system is expected to tolerate an error of 6-7 times bigger than that with analyzer grating stepping.
引用
收藏
页数:6
相关论文
共 24 条
  • [1] Performance Evaluation of a Differential Phase-contrast Cone-beam (DPC-CBCT) System for Soft Tissue Imaging
    Yu, Yang
    Ning, Ruola
    Cai, Weixing
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [2] Phantom Study for Volume-of-Interest Breast Imaging using Differential Phase Contrast Cone Beam CT (DPC-CBCT)
    Liu, Jiangkun
    Ning, Ruola
    Cai, Weixing
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [3] Evaluation of differential phase contrast cone beam CT imaging system
    Liu, Jiangkun
    Cai, Weixing
    Ning, Ruola
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2017, 25 (03) : 357 - 372
  • [4] Cone-beam differential phase-contrast laminography with x-ray tube source
    Fu, J.
    Biernath, T.
    Willner, M.
    Amberger, M.
    Meiser, J.
    Kunka, D.
    Mohr, J.
    Herzen, J.
    Bech, M.
    Pfeiffer, F.
    EPL, 2014, 106 (06)
  • [5] Performance Investigation of a Hospital-grade X-ray Tube-based Differential Phase-contrast Cone Beam CT System
    Yu, Yang
    Ning, Ruola
    Cai, Weixing
    Liu, Jiangkun
    Conover, David
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [6] Single-slice reconstruction method for helical cone-beam differential phase-contrast CT
    Fu, Jian
    Chen, Liyuan
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (01) : 45 - 51
  • [7] Design and Construction of a Micro-focus In-line Phase-contrast Cone Beam CT (PC-CBCT) System for Soft Tissue Imaging
    Cai, Weixing
    Ning, Ruola
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [8] Investigation of Moire Pattern-based Phase Retrieval Approach for Differential Phase-contrast Cone Beam CT Imaging Using a Hospital-grade Tube
    Cai, Weixing
    Ning, Ruola
    Yu, Yang
    Liu, Jiangkun
    Conover, David
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [9] Detection performance study for cone-beam differential phase contrast CT
    Li, Ke
    Bevins, Nicholas
    Zambelli, Joseph
    Qi, Zhihua
    Chen, Guang-Hong
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [10] An approximate reconstruction method for helical cone-beam differential phase-contrast computed tomography images
    Li, Jing
    Zhu, Peiping
    Sun, Yi
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (08): : 2347 - 2356