Phantom Study for Volume-of-Interest Breast Imaging using Differential Phase Contrast Cone Beam CT (DPC-CBCT)

被引:0
|
作者
Liu, Jiangkun [1 ]
Ning, Ruola [1 ,2 ]
Cai, Weixing [2 ]
机构
[1] Univ Rochester, Dept Elect & Comp Engn, Rochester, NY 14627 USA
[2] Univ Rochester, Med Ctr, Dept Imaging Sci, Rochester, NY 14642 USA
关键词
Differential phase contrast; Cone beam CT; Volume of interest; Breast imaging;
D O I
10.1117/12.2007159
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Differential phase contrast (DPC) imaging is reported to be able to deliver higher contrast-to-noise ratio (CNR) compared to attenuation-based x-ray imaging technologies. Due to the nature of attenuation contrast, the conventional cone beam CT (CBCT) technology has limitations in characterizing breast lesions with sufficiently high contrast and spatial resolution. As an alternative, the grating-based DPC-CBCT technology is potentially a powerful tool for breast imaging. However, limited by current grating fabrication techniques, a full field-of-view (FOV) that covers the whole breast is not practical at present. Previously by our group, a volume-of-interest (VOI) imaging method, which incorporates DPC-CBCT into a dedicated attenuation-based CBCT imaging system, was presented. In the method, the CBCT scan was performed to localize the suspicious volume and then a VOI scan by DPC-CBCT characterized the suspicious volume with higher contrast and resolution. In this work, we investigated the performance of DPC-CBCT VOI imaging by performing a phantom study using our bench-top DPC-CBCT system with a hospital-grade X-ray tube. A cylinder water phantom with a size of over twice of the FOV of our DPC-CBCT system was designed. The phantom contains four different materials and it was scanned at four different dose levels. In thick object scanning, phase wrapping errors cause artifacts for DPC-CBCT VOI imaging. A low-pass filter was designed to reduce the artifacts. In order to compare the DPC-CBCT VOI with attenuation-based CBCT, the scanning data were used to reconstruct both phase coefficient image and attenuation coefficient image. The reconstructed images will be quantitatively and visually evaluated with regards to contrast, noise level and artifacts.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Investigation of Source Grating Stepping for Differential Phase-contrast Cone Beam CT (DPC-CBCT) System
    Cai, Weixing
    Yu, Yang
    Ning, Ruola
    Liu, Jiangkun
    Conover, David
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [2] Performance Evaluation of a Differential Phase-contrast Cone-beam (DPC-CBCT) System for Soft Tissue Imaging
    Yu, Yang
    Ning, Ruola
    Cai, Weixing
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [3] Contrast-to-Noise Ratio Improvement in Volume-of-Interest Cone Beam Breast CT
    Shen, Youtao
    Liu, Xinming
    Lai, Chao-Jen
    Zhong, Yuncheng
    Yi, Ying
    You, Zhicheng
    Wang, Tianpeng
    Shaw, Chris C.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [4] A volume-of-interest (VOI) scanning technique for cone beam breast CT
    Chen, L
    Shaw, C
    Altunbas, M
    Wang, T
    Tu, S
    Lai, C
    Liu, X
    MEDICAL PHYSICS, 2005, 32 (06) : 2064 - 2065
  • [5] Feasibility of volume-of-interest (VOI) scanning technique in cone beam breast CT - a preliminary study
    Chen, Lingyun
    Shaw, Chris C.
    Altunbas, Mustafa C.
    Lai, Chao-Jen
    Liu, Xinming
    Han, Tao
    Wang, Tianpeng
    Yang, Wei T.
    Whitman, Gary J.
    MEDICAL PHYSICS, 2008, 35 (08) : 3482 - 3490
  • [6] A Novel Technology for Volume-Of-Interest KV Cone Beam CT
    Robar, J.
    MEDICAL PHYSICS, 2012, 39 (06) : 3999 - 4000
  • [7] Reduction in x-ray scatter and radiation dose for volume-of-interest (VOI) cone-beam breast CT-a phantom study
    Lai, Chao-Jen
    Chen, Lingyun
    Zhang, Huojun
    Liu, Xinming
    Zhong, Yuncheng
    Shen, Youtao
    Han, Tao
    Ge, Shuaiping
    Yi, Ying
    Wang, Tianpeng
    Yang, Wei T.
    Whitman, Gary J.
    Shaw, Chris C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (21): : 6691 - 6709
  • [8] Doses in Volume-Of-Interest Cone-Beam Computed Tomography (CBCT)- a Monte Carlo Simulation Study
    Yi, Y.
    Shen, Y.
    Lai, C.
    Liu, X.
    Zhong, Y.
    Ge, S.
    You, Z.
    Wang, T.
    Shaw, C.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [9] Volume-of-interest cone-beam CT using a 2.35 MV beam generated with a carbon target
    Robar, James L.
    Parsons, David
    Berman, Avery
    MacDonald, Alex
    MEDICAL PHYSICS, 2012, 39 (07) : 4209 - 4218
  • [10] Improving Brain Soft-Tissue Contrast with Iterative Reconstruction of Volume-Of-Interest Cone-Beam CT
    Huynh, C.
    Ruschin, M.
    Hashemi, S.
    Lee, Y.
    Mainprize, J.
    Nordstrom, H.
    Eriksson, Ni
    Grouza, V.
    Sahgal, A.
    Grafe, J.
    Song, W.
    MEDICAL PHYSICS, 2017, 44 (06)