Evaluation of scattered radiation effect on breast cone-beam CT image: A phantom study

被引:0
|
作者
Kwan, A [1 ]
Boone, J [1 ]
Yang, K [1 ]
Shah, N [1 ]
机构
[1] Univ Calif Davis, Dept Radiol, Med Ctr, Sacramento, CA 95817 USA
关键词
D O I
10.1118/1.1998282
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantify the impact of scattered radiation on CT image reconstruction. Method and Materials: A 14 cm diameter cylindrical 50/50 (50% glandular/50% adipose) tissue equivalent phantom was used to assess CT scatter conditions in a custom build cone‐beam breast CT scanner. The amount of scatter was varied by controlling the vertical dimension of the collimator opening (in the cone angle direction), which ranged from 16.8 to 100.2 mm at isocenter. Four data sets were acquired for each collimation, two with a 50/50 tissue equivalent rod and two with a 100% glandular tissue equivalent rod at the center of the phantom, with a scan technique of 80 kVp, 5 mA and 16.6 s (500 views). The images were reconstructed at the exact location for all the different collimated images, and the CNR was used to assess the image quality as a function of scatter to primary ratio (SPR). Results: As the amount of scatter (collimator gap) increases, the cupping artifact in the reconstructed image increases slightly. The CNR dropped from 2.6 at 16.8 mm collimation to 2.0 at 22.5 mm collimation, and remained at about 2.0 with further increases in the gap's width. Conclusion: Based on the preliminary results presented here, the scatter radiation increased the cupping artifact in the reconstructed image and reduced the CNR. However, the reduction in CNR appears to occur most dramatically at lower SPR and does not worsen significantly as the scatter increases from moderate (SPR = 0.1) to high (SPR = 0.5) levels. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2064 / 2064
页数:1
相关论文
共 50 条
  • [1] Cone-Beam CT for Breast Specimens in Surgery: The Phantom Study
    Thongvigitmanee, Saowapak S.
    Aootaphao, Sorapong
    Thanasupsombat, Chalinee
    Kiang-ia, Atthasak
    Narkbuakaew, Walita
    Wangkaoom, Kongyot
    Junhunee, Parinya
    Laohawiriyakamol, Suphawat
    Puttawibul, Puttisak
    Thajchayapong, Pairash
    2018 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE PROCEEDINGS (NSS/MIC), 2018,
  • [2] Effect of scattered radiation on image noise in cone beam CT
    Endo, M
    Tsunoo, T
    Nakamori, N
    Yoshida, K
    MEDICAL PHYSICS, 2001, 28 (04) : 469 - 474
  • [3] Cone-Beam CT for Breast Imaging: Radiation Dose, Breast Coverage, and Image Quality
    O'Connell, Avice
    Conover, David L.
    Zhang, Yan
    Seifert, Posy
    Logan-Young, Wende
    Lin, Chuen-Fu Linda
    Sahler, Lawrence
    Ning, Ruola
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (02) : 496 - 509
  • [4] Evaluation of a physical based approach of scattered radiation correction in cone beam CT with an anthropomorphic thorax phantom
    Rinkel, Jean
    Gerfault, Laurent
    Esteve, Francois
    Dinten, Jean-Marc
    Medical Imaging 2006: Physics of Medical Imaging, Pts 1-3, 2006, 6142 : B1421 - B1421
  • [5] An in vitro evaluation of cone-beam breast CT methods
    Zeng, Kai
    Fajardo, Laurie L.
    Kao, Simon
    Franken, Edmund A.
    Park, Jeong Mi
    Jing, Zhenxue
    Bai, Er-wei
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2008, 16 (03) : 171 - 187
  • [6] Radiation Dose Reduction and Image Quality Evaluation of Coronal Truncated Projections in Cone-Beam Dedicated Breast CT
    Konate, S.
    Vedantham, S.
    Shi, L.
    Karellas, A.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [7] Radiation dose evaluation in tomosynthesis and C-arm cone-beam CT examinations with an anthropomorphic phantom
    Koyama, Shuji
    Aoyama, Takahiko
    Oda, Nobuhiro
    Yamauchi-Kawaura, Chiyo
    MEDICAL PHYSICS, 2010, 37 (08) : 4298 - 4306
  • [8] Simulating low-dose cone-beam CT: a phantom study
    Ferrero, Andrea
    Fetterly, Ken
    Yu, Lifeng
    Schueler, Beth
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [9] Phantom development for artifact reduction in cone-beam CT
    Keely, A.
    Kyprianou, I.
    Jennings, R.
    Myers, K.
    Gilat-Schmidt, T.
    MEDICAL PHYSICS, 2007, 34 (06) : 2340 - 2340
  • [10] Analysis of scatter artifacts in cone-beam CT due to scattered radiation of metallic objects
    Iuso, Domenico
    Frysch, Robert
    Pfeiffer, Tim
    Rose, Georg
    15TH INTERNATIONAL MEETING ON FULLY THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 2019, 11072