Evaluation of scattered radiation effect on breast cone-beam CT image: A phantom study

被引:0
|
作者
Kwan, A [1 ]
Boone, J [1 ]
Yang, K [1 ]
Shah, N [1 ]
机构
[1] Univ Calif Davis, Dept Radiol, Med Ctr, Sacramento, CA 95817 USA
关键词
D O I
10.1118/1.1998282
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To quantify the impact of scattered radiation on CT image reconstruction. Method and Materials: A 14 cm diameter cylindrical 50/50 (50% glandular/50% adipose) tissue equivalent phantom was used to assess CT scatter conditions in a custom build cone‐beam breast CT scanner. The amount of scatter was varied by controlling the vertical dimension of the collimator opening (in the cone angle direction), which ranged from 16.8 to 100.2 mm at isocenter. Four data sets were acquired for each collimation, two with a 50/50 tissue equivalent rod and two with a 100% glandular tissue equivalent rod at the center of the phantom, with a scan technique of 80 kVp, 5 mA and 16.6 s (500 views). The images were reconstructed at the exact location for all the different collimated images, and the CNR was used to assess the image quality as a function of scatter to primary ratio (SPR). Results: As the amount of scatter (collimator gap) increases, the cupping artifact in the reconstructed image increases slightly. The CNR dropped from 2.6 at 16.8 mm collimation to 2.0 at 22.5 mm collimation, and remained at about 2.0 with further increases in the gap's width. Conclusion: Based on the preliminary results presented here, the scatter radiation increased the cupping artifact in the reconstructed image and reduced the CNR. However, the reduction in CNR appears to occur most dramatically at lower SPR and does not worsen significantly as the scatter increases from moderate (SPR = 0.1) to high (SPR = 0.5) levels. © 2005, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2064 / 2064
页数:1
相关论文
共 50 条
  • [21] Helical cone-beam CT for radiation therapy
    Yu, LF
    Pan, XC
    Pelizzari, CA
    Zou, Y
    Munro, P
    Riem, H
    Kaissl, W
    MEDICAL PHYSICS, 2005, 32 (06) : 1890 - 1890
  • [22] Dose Distribution in Cone-Beam Breast Computed Tomography: An Experimental Phantom Study
    Russo, Paolo
    Lauria, Adele
    Mettivier, Giovanni
    Montesi, Maria Cristina
    Villani, Natalia
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (01) : 366 - 374
  • [23] Evaluation of spatial precision and accuracy of cone-beam CT using an in vitro phantom model
    Bocca, Leonardo Favi
    Tiefenbach, Jakov
    Sonneborn, Claire
    Hogue, Olivia
    Dorn, Kristina
    Painter, Tracy
    Centeno, Ricardo S.
    Baker, Kenneth B.
    Machado, Andre G.
    JOURNAL OF NEUROSURGERY, 2024, 140 (03) : 849 - 855
  • [24] Dose Distribution in Cone-Beam Breast Computed Tomography: an experimental Phantom Study
    Russo, P.
    Lauria, A.
    Mettivier, G.
    Montesi, M. C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 5382 - 5387
  • [25] Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner
    Kwan, Alexander L. C.
    Boone, John M.
    Yang, Kai
    Huang, Shih-Ying
    MEDICAL PHYSICS, 2007, 34 (01) : 275 - 281
  • [26] Evaluation of Patient Dose Reduction in Kilovoltage Cone-beam CT for Image-guided Radiation Therapy
    Noto, K.
    Ueda, S.
    Syouji, S.
    Hori, N.
    Kurata, Y.
    Yamamoto, T.
    Takemura, A.
    Matsubara, K.
    Koshida, K.
    Takamatsu, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S742 - S742
  • [27] Cone-Beam Artifacts in Dedicated Breast CT
    Vedantham, S.
    Shi, L.
    Noo, F.
    Glick, S.
    Karellas, A.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [28] Congruence of Cone-Beam CT Image Center with the Radiation Isocenter of a Linear Accelerator
    Du, W.
    Yang, J.
    Chang, E.
    Luo, D.
    McAleer, M.
    Shiu, A.
    Martel, M.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [29] Exact image reconstruction in reverse helical cone-beam CT for radiation therapy
    Cho, S.
    Xia, D.
    Pelizzari, C.
    Pan, X.
    MEDICAL PHYSICS, 2007, 34 (06) : 2633 - 2634
  • [30] Clinical implementation of cone-beam CT for image-guided radiation therapy
    Zhu, X. R.
    Zhang, L.
    Kudchadker, R.
    Wu, R.
    Balter, P.
    Mohan, R.
    Gillin, M.
    Dong, L.
    MEDICAL PHYSICS, 2006, 33 (06) : 2268 - 2268