Phantom development for artifact reduction in cone-beam CT

被引:0
|
作者
Keely, A.
Kyprianou, I.
Jennings, R.
Myers, K.
Gilat-Schmidt, T.
机构
[1] Marquette Univ, Milwaukee, WI 53233 USA
[2] US FDA, Ctr Device & Radiol Hlth, Silver Spring, MD USA
关键词
D O I
10.1118/1.2760389
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We developed a cone‐beam CT phantom for bone, metal, and beam hardening artifact evaluation. The two measures that can be tested are resolution and soft tissue discrimination. We will use this phantom to investigate beam filtrations for artifact reduction, resolution, and soft tissue discrimination. Method and Materials: The cylindrical PMMA phantom designed for cone‐beam CT (radius 12 cm, height 19 cm) is non‐uniform in the z‐direction. The phantom incorporates several different structures to test for bone and metal artifacts, as well as small object discrimination. A human skull fragment placed at the center of the cylinder tests for bone artifacts. Metal wires were placed horizontally and vertically through the cylinder. BBs were inserted on‐top of the skull fragment which were used for automatic object alignment. Both of these metal components were also used to generate metal artifacts. The phantom includes a soft tissue discrimination block with five different densities. Two additional blocks are used to test for small object discrimination in the horizontal and vertical directions. 24 BBs were inserted into the rims of the PMMA cylinder (top and bottom of phantom) and were used for the geometric reconstruction of the image acquisition trajectory. Results: The phantom was scanned on a bench‐top cone‐beam CT system with three different k‐edge filters, Er (0.127 mm), Er (0.254 mm), and Yb (0.254 mm). The resulting artifacts in the reconstructed images were assessed qualitatively. The data were reconstructed, and artifacts from the bone, wires, and BBs were observed to vary depending on the specific beam filtration used. Conclusion: We have developed a cone beam CT phantom for artifact evaluation and imaging technique optimization. The potential imaging techniques that can benefit are breast, brain, and extremity cone beam CT. Future work: develop a task specific figure of merit for artifact evaluation. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2340 / 2340
页数:1
相关论文
共 50 条
  • [1] Metal Artifact Reduction in Cone-beam CT by Constrained Optimization
    Zhang, X.
    Wang, J.
    Xing, L.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S652 - S652
  • [2] Convolutional Network Based Motion Artifact Reduction in Cone-Beam CT
    Paysan, P.
    Strzelecki, A.
    Arrate, F.
    Munro, P.
    Scheib, S.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E340 - E341
  • [3] Image artifact in dental cone-beam CT
    Katsumata, A
    Hirukawa, A
    Noujeim, M
    Okumura, S
    Naitoh, M
    Fujishita, M
    Ariji, E
    Langlais, RP
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 101 (05): : 652 - 657
  • [4] Penalized-Likelihood Reconstruction for Metal Artifact Reduction in Cone-Beam CT
    Aootaphao, Sorapong
    Pintavirooj, Chuchart
    Sotthivirat, Saowapak
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2733 - 2736
  • [5] Development and applicability of a quality control phantom for dental cone-beam CT
    Pauwels, Ruben
    Stamatakis, Harry
    Manousaridis, Giorgos
    Walker, Adrian
    Michielsen, Koen
    Bosmans, Hilde
    Bogaerts, Ria
    Jacobs, Reinhilde
    Horner, Keith
    Tsiklakis, Kostas
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2011, 12 (04): : 245 - 260
  • [6] INDEPENDENT COMPONENT ANALYSIS BASED RING ARTIFACT REDUCTION IN CONE-BEAM CT IMAGES
    Chen, Yen-Wei
    Duan, Guifen
    [J]. 2009 16TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOLS 1-6, 2009, : 4189 - 4192
  • [7] Metal Artifact Reduction in Helical Cone-beam Computed Tomography
    Tang, Jie
    Zhang, Li
    Chen, Zhiqiang
    Xing, Yuxiang
    Cheng, Jianping
    [J]. 2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2878 - 2881
  • [8] Moving metal artifact reduction in cone-beam CT scans with implanted cylindrical gold markers
    Toftegaard, Jakob
    Fledelius, Walther
    Seghers, Dieter
    Huber, Michael
    Brehm, Marcus
    Worm, Esben S.
    Elstrom, Ulrik V.
    Poulsen, Per R.
    [J]. MEDICAL PHYSICS, 2014, 41 (12)
  • [9] Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT
    Zbijewski, Wojciech
    Beekman, Freek J.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (07) : 817 - 827
  • [10] Known-component metal artifact reduction (KC-MAR) for cone-beam CT
    Uneri, A.
    Zhang, X.
    Yi, T.
    Stayman, J. W.
    Helm, P. A.
    Osgood, G. M.
    Theodore, N.
    Siewerdsen, J. H.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (16):