Phantom development for artifact reduction in cone-beam CT

被引:0
|
作者
Keely, A.
Kyprianou, I.
Jennings, R.
Myers, K.
Gilat-Schmidt, T.
机构
[1] Marquette Univ, Milwaukee, WI 53233 USA
[2] US FDA, Ctr Device & Radiol Hlth, Silver Spring, MD USA
关键词
D O I
10.1118/1.2760389
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We developed a cone‐beam CT phantom for bone, metal, and beam hardening artifact evaluation. The two measures that can be tested are resolution and soft tissue discrimination. We will use this phantom to investigate beam filtrations for artifact reduction, resolution, and soft tissue discrimination. Method and Materials: The cylindrical PMMA phantom designed for cone‐beam CT (radius 12 cm, height 19 cm) is non‐uniform in the z‐direction. The phantom incorporates several different structures to test for bone and metal artifacts, as well as small object discrimination. A human skull fragment placed at the center of the cylinder tests for bone artifacts. Metal wires were placed horizontally and vertically through the cylinder. BBs were inserted on‐top of the skull fragment which were used for automatic object alignment. Both of these metal components were also used to generate metal artifacts. The phantom includes a soft tissue discrimination block with five different densities. Two additional blocks are used to test for small object discrimination in the horizontal and vertical directions. 24 BBs were inserted into the rims of the PMMA cylinder (top and bottom of phantom) and were used for the geometric reconstruction of the image acquisition trajectory. Results: The phantom was scanned on a bench‐top cone‐beam CT system with three different k‐edge filters, Er (0.127 mm), Er (0.254 mm), and Yb (0.254 mm). The resulting artifacts in the reconstructed images were assessed qualitatively. The data were reconstructed, and artifacts from the bone, wires, and BBs were observed to vary depending on the specific beam filtration used. Conclusion: We have developed a cone beam CT phantom for artifact evaluation and imaging technique optimization. The potential imaging techniques that can benefit are breast, brain, and extremity cone beam CT. Future work: develop a task specific figure of merit for artifact evaluation. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2340 / 2340
页数:1
相关论文
共 50 条
  • [41] Reduction of artifacts induced by misaligned geometry in cone-beam CT
    Sun, Yi
    Hou, Ying
    Hu, Jiasheng
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2007, 54 (08) : 1461 - 1471
  • [42] AN ALGORITHM FOR METAL STREAKING ARTIFACT REDUCTION IN CONE BEAM CT FOR BRACHYTHERAPY
    Bazalova, M.
    Landry, G.
    Beaulieu, L.
    Verhaegen, F.
    RADIOTHERAPY AND ONCOLOGY, 2009, 92 : S101 - S101
  • [43] Streak artifact reduction in helical cone beam CT with redundancy weighting
    Zamyatin, Alexander A.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 4148 - 4149
  • [44] Real-Time Delineation of Implanted Cardioverter-Defibrillators and Metal Artifact Reduction in Cardiac Cone-Beam CT
    Park, I.
    Chun, J.
    Olberg, S.
    Cai, B.
    Hugo, G.
    Robinson, C. G.
    Kim, J.
    Mutic, S.
    Park, J.
    MEDICAL PHYSICS, 2020, 47 (06) : E444 - E444
  • [45] The Investigation and Correction of a Bowtie-Related Cone-Beam CT Circular Band Artifact
    Zheng, D.
    Lazos, D.
    Lu, J.
    Zhang, L.
    Pokhrel, D.
    Williamson, J.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [46] Influence of Data Completion on Scatter Artifact Correction for Truncated Cone-Beam CT Data
    Waltrich, Nadine
    Sawall, Stefan
    Maier, Joscha
    Kuntz, Jan
    Stannigel, Kai
    Lindenberg, Kai
    Kachelriess, Marc
    MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING, 2018, 10573
  • [47] C-arm orbits for metal artifact avoidance (MAA) in cone-beam CT
    Wu, P.
    Sheth, N.
    Sisniega, A.
    Uneri, A.
    Han, R.
    Vijayan, R.
    Vagdargi, P.
    Kreher, B.
    Kunze, H.
    Kleinszig, G.
    Vogt, S.
    Lo, S-F
    Theodore, N.
    Siewerdsen, J. H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (16):
  • [48] Comparing Short Scan CT Reconstruction Algorithms Regarding Cone-Beam Artifact Performance
    Maass, Clemens
    Dennerlein, Frank
    Noo, Frederic
    Kachelriess, Marc
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 2188 - 2193
  • [49] Cone-Beam CT Scatter Artifact Removal with Deep Residual Generative Adversarial Network
    Qin, N.
    Gonzalez, Y.
    Shen, C.
    Shieh, C.
    Jia, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E704 - E704
  • [50] Development and Characterization of a Dynamic, Anatomically Realistic, Abdominal Phantom for Simulating Complex Deformable Motion in Cone-Beam CT
    Liu, Y.
    Huang, H.
    Siewerdsen, J.
    Zbijewski, W.
    Weiss, C.
    Ehtiati, T.
    Sisniega, A.
    MEDICAL PHYSICS, 2021, 48 (06)