Phantom development for artifact reduction in cone-beam CT

被引:0
|
作者
Keely, A.
Kyprianou, I.
Jennings, R.
Myers, K.
Gilat-Schmidt, T.
机构
[1] Marquette Univ, Milwaukee, WI 53233 USA
[2] US FDA, Ctr Device & Radiol Hlth, Silver Spring, MD USA
关键词
D O I
10.1118/1.2760389
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: We developed a cone‐beam CT phantom for bone, metal, and beam hardening artifact evaluation. The two measures that can be tested are resolution and soft tissue discrimination. We will use this phantom to investigate beam filtrations for artifact reduction, resolution, and soft tissue discrimination. Method and Materials: The cylindrical PMMA phantom designed for cone‐beam CT (radius 12 cm, height 19 cm) is non‐uniform in the z‐direction. The phantom incorporates several different structures to test for bone and metal artifacts, as well as small object discrimination. A human skull fragment placed at the center of the cylinder tests for bone artifacts. Metal wires were placed horizontally and vertically through the cylinder. BBs were inserted on‐top of the skull fragment which were used for automatic object alignment. Both of these metal components were also used to generate metal artifacts. The phantom includes a soft tissue discrimination block with five different densities. Two additional blocks are used to test for small object discrimination in the horizontal and vertical directions. 24 BBs were inserted into the rims of the PMMA cylinder (top and bottom of phantom) and were used for the geometric reconstruction of the image acquisition trajectory. Results: The phantom was scanned on a bench‐top cone‐beam CT system with three different k‐edge filters, Er (0.127 mm), Er (0.254 mm), and Yb (0.254 mm). The resulting artifacts in the reconstructed images were assessed qualitatively. The data were reconstructed, and artifacts from the bone, wires, and BBs were observed to vary depending on the specific beam filtration used. Conclusion: We have developed a cone beam CT phantom for artifact evaluation and imaging technique optimization. The potential imaging techniques that can benefit are breast, brain, and extremity cone beam CT. Future work: develop a task specific figure of merit for artifact evaluation. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2340 / 2340
页数:1
相关论文
共 50 条
  • [31] Cone-Beam Artifact Reduction Using Second Pass Radon Space Filling
    Erhard, Klaus
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 3426 - 3428
  • [32] METAL ARTIFACT REDUCTION IN CONE-BEAM EXTREMITY IMAGES USING GATED CONVOLUTIONS
    Agrawal, Harshit
    Hietanen, Ari
    Sarkka, Simo
    2021 IEEE 18TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2021, : 1087 - 1090
  • [33] Metal Artifact Reduction based on 2D-Projection Correction for Dental Cone-beam CT Images
    Narkbuakaew, Walita
    Aootaphao, Sorapong
    Thanasupsombat, Chalinee
    Thongvigitmanee, Saowapak S.
    13TH BIOMEDICAL ENGINEERING INTERNATIONAL CONFERENCE (BMEICON 2021), 2018,
  • [34] Utilization of tin filters for streak artifact reduction in cone-beam computed tomography
    Minsoo Chun
    Jin Hwa Choi
    Ohyun Kwon
    Hyeongmin Jin
    Sung Young Lee
    Chang Heon Choi
    Jung-in Kim
    Jong Min Park
    Journal of the Korean Physical Society, 2022, 80 : 1018 - 1027
  • [35] Metal Artifact Reduction in Cone-Beam Computed Tomography for Head and Neck Radiotherapy
    Korpics, Mark
    Johnson, Paul
    Patel, Rakesh
    Surucu, Murat
    Choi, Mehee
    Emami, Bahman
    Roeske, John C.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2016, 15 (06) : NP88 - NP94
  • [36] Utilization of tin filters for streak artifact reduction in cone-beam computed tomography
    Chun, Minsoo
    Choi, Jin Hwa
    Kwon, Ohyun
    Jin, Hyeongmin
    Lee, Sung Young
    Choi, Chang Heon
    Kim, Jung-in
    Park, Jong Min
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 80 (10) : 1018 - 1027
  • [37] Cone-beam artifact evaluation of the factorization method
    Dennerlein, Frank
    Noo, Frederic
    MEDICAL PHYSICS, 2011, 38 : S18 - S24
  • [38] Efficient high cone-angle artifact reduction in circular cone-beam CT using deep learning with geometry-aware dimension reduction
    Minnema, Jordi
    van Eijnatten, Maureen
    der Sarkissian, Henri
    Doyle, Shannon
    Koivisto, Juha
    Wolff, Jan
    Forouzanfar, Tymour
    Lucka, Felix
    Batenburg, Kees Joost
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (13):
  • [39] Cone-beam CT dose and imaging performance evaluation with a modular, multipurpose phantom
    Siewerdsen, J. H.
    Uneri, A.
    Hernandez, A. M.
    Burkett, G. W.
    Boone, J. M.
    MEDICAL PHYSICS, 2020, 47 (02) : 467 - 479
  • [40] CT Based Simulation Framework for Motion Artifact and Ground Truth Generation of Cone-Beam CT
    Paysan, P.
    Munro, P.
    Scheib, S.
    MEDICAL PHYSICS, 2019, 46 (06) : E152 - E152