Efficient Monte Carlo based scatter artifact reduction in cone-beam micro-CT

被引:122
|
作者
Zbijewski, Wojciech
Beekman, Freek J.
机构
[1] Image Sci Inst, Dept Nucl Med, NL-3584 CG Utrecht, Netherlands
[2] Rudolf Magnus Inst Neurosci, Dept Pharmacol & Anat, NL-3584 CG Utrecht, Netherlands
关键词
artifact removal; computed tomography; cone beam; image reconstruction; medical imaging; Monte Carlo simulation; scatter;
D O I
10.1109/TMI.2006.872328
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Cupping and streak artifacts caused by the detection of scattered photons may severely degrade the quantitative accuracy of cone-beam X-ray computed tomography (CT) images. In order to overcome this problem, we propose and validate the following iterative scatter artifact reduction scheme. First, an initial image is reconstructed from the scatter-contaminated projections. Next, the scatter component of the projections is estimated from the initial reconstruction by a Monte Carlo (MC) simulation. The estimate obtained is then utilized during the reconstruction of a scatter-corrected image. The last two steps are repeated until an adequate correction is obtained. The estimation of the noise-free scatter projections in this scheme is accelerated in the following way: first, a rapid (i.e., based on a low number of simulated photon tracks) MC simulation is executed. The noisy result of this simulation is de-noised by a three-dimensional fitting of Gaussian basis functions. We demonstrate that, compared to plain MC, this method shortens the required simulation time by three to four orders of magnitude. Using simulated projections of a small animal phantom, we show that one cycle of the scatter correction scheme is sufficient to produce reconstructed images that barely differ from the reconstructions of scatter-free projections. The reconstructions of data acquired with a charge-coupled device based micro-CT scanner demonstrate a nearly complete removal of the scatter-induced cupping artifact. Quantitative errors in a water phantom are reduced from around 12% for reconstructions without the scatter correction to 1% after the proposed scatter correction has been applied. In conclusion, a general, accurate, and efficient scatter correction algorithm is developed that requires no mechanical modifications of the scanning equipment and results in only a moderate increase in the total reconstruction time.
引用
收藏
页码:817 / 827
页数:11
相关论文
共 50 条
  • [1] An efficient Monte Carlo-based algorithm for scatter correction in keV cone-beam CT
    Poludniowski, G.
    Evans, P. M.
    Hansen, V. N.
    Webb, S.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (12): : 3847 - 3864
  • [2] Monte Carlo evaluation of scatter mitigation strategies in cone-beam CT
    Lazos, Dimitrios
    Williamson, Jeffrey F.
    [J]. MEDICAL PHYSICS, 2010, 37 (10) : 5456 - 5470
  • [3] Cone-beam reconstruction for micro-CT
    Wang, G
    Jiang, M
    Lee, SW
    Liu, H
    Hoffman, E
    [J]. 2002 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, PROCEEDINGS, 2002, : 384 - 387
  • [4] Exploration of the Scatter Distribution in Cone-Beam CT Using Monte Carlo Techniques
    Bootsma, G.
    Verhaegen, F.
    Jaffray, D.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [5] Ultrafast Cone-Beam CT Scatter Correction with GPU-Based Monte Carlo Simulation
    Xu, Y.
    Bai, T.
    Yan, H.
    Ouyang, L.
    Wang, J.
    Pompos, A.
    Zhou, L.
    Jiang, S.
    Jia, X.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 540 - +
  • [6] Cone-beam Micro-CT system based on LabVIEW software
    Ionita, Ciprian N.
    Hoffmann, Keneth R.
    Bednarek, Daniel R.
    Chityala, Ravishankar
    Rudin, Stephen
    [J]. JOURNAL OF DIGITAL IMAGING, 2008, 21 (03) : 296 - 305
  • [7] Cone-Beam Micro-CT System Based on LabVIEW Software
    Ciprian N. Ionita
    Keneth R. Hoffmann
    Daniel R. Bednarek
    Ravishankar Chityala
    Stephen Rudin
    [J]. Journal of Digital Imaging, 2008, 21 : 296 - 305
  • [8] Framework for iterative cone-beam micro-CT reconstruction
    Benson, TM
    Gregor, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1335 - 1340
  • [9] Framework for iterative cone-beam micro-CT reconstruction
    Benson, T
    Gregor, J
    [J]. 2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3253 - 3257
  • [10] HELICAL DUAL SOURCE CONE-BEAM MICRO-CT
    Johnston, Samuel M.
    Johnson, G. Allan
    Badea, Cristian T.
    [J]. 2014 IEEE 11th International Symposium on Biomedical Imaging (ISBI), 2014, : 177 - 180